Handwheel HKD
- 100 detents per revolution
- Wear-free magnetic detent mechanism
- 100 pulses per revolution
- Installation in operator panels and EUCHNER hand-held pendant stations series HBL
Description
Functional drawings
Dimensional drawings
Connection examples
Technical data
Approvals
Electrical connection values
Connection cross section | 0.08 ... 2.5 mm² |
Connection cross section AWG | 28 ... 12 AWG |
Output type | Push-pull |
Output voltage | |
LOW(0) | max. 3 V DC at 20 mA |
HIGH(1) | min. Ub-3 V DC at 20 mA |
Operating voltage DC | 10 ... 30 V DC |
EMC protection requirements | |
according to CE | EN 61000-6-2, EN 61000-6-4 |
Pulses per revolution | 2x100 |
Current consumption | |
without load | max. 80 mA |
Mechanical values and environment
Connection type | Screw terminal, 6-pin |
Tightening torque | max. 0.5 Nm |
Atmospheric humidity | |
(condensation not permissible) | 80 % rH |
Detent positions per revolution | 100 |
Shock and vibration resistance | according to EN 60068-2-27/-2-6 |
Degree of protection | |
IP65 (When installed) | |
according to NEMA | 250-12 (When installed) |
Ambient temperature | 0 ... +70 °C |
Material | Aluminum |
Miscellaneous
Detent mechanism | Magnetic |
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
Other Documents
CAD data
Ordering data
Ordernumber | 054868 |
Item designation | HKD100S100G24 |
Gross weight | 0,344kg |
Customs tariff number | 85365019000 |
ECLASS | 27-24-23-07 Command-, control-, signal appliance |