ZSR, housing G2, 3-stage, with cable
- 3-stage function
- Housing G2
- Straight connecting cable, 10 m
- Including holder
Description
Switching element
2210 | 1 NO/NC 1 NO (additional monitoring contact) |
Cable
The high-quality connecting cables (individual screening of the safety contacts) are available in a straight version.
3-stage function
Enabling function is active only in the second stage (center position, actuating point). If the pushbutton is released or pushed further (panic function), the enabling is removed (dependent on the wiring, see function sequence).
Dimensional drawings
Dimensional drawings
Connection examples
Shift travel diagrams
closed, enabling | |
closed | |
open |
Technical data
Approvals
Electrical connection values
Connecting cable | 3x0.75 mm² (2x0.75 mm² screened + 1x0.75 mm² unscreened) |
rated conditional short-circuit current | 100 A |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Utilization category | |
AC-15 | 4 A 230 V |
DC-13 | 3 A 24 V |
Short circuit protection according to IEC 60269-1 | 4A gG (In case of operating voltages other than 24 V, the short circuit protection must be dimensioned accordingly and checked.) |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
Switching characteristics | 3-stage enabling switch |
Degree of contamination (external, according to EN 60947-1) | 3 |
Mechanical values and environment
Connection type | flying lead |
Number of NO contacts | 2 |
Number of positively driven contacts | 1 |
Cable length | |
straight | 10 m |
Mechanical life | |
Position 1-2-3-1 | 0.1 x 10⁶ |
Position 1-2-1 | 0.1 x 10⁶ |
Switching principle | Slow-action contact element |
Degree of protection | IP65 |
Ambient temperature | -5 ... +50 °C |
Material | |
Cap | Elastomer, low PAH, black |
Housing | Plastic, yellow |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Enabling switch | |
B10D | 0.5 x 10⁶ |
Miscellaneous
in compliance with | 60947-5-8 |
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2109392
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001579
Version
Language
Size
0,1 MB
Other Documents
Approvals and certificates
CCC
Doc. no.
Version
Language
Size
CCC
Doc. no.
20001751
Version
Language
Size
0,0 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
0,2 MB
CAD data
Ordering data
Ordernumber | 055432 |
Item designation | ZSR2B2G10A |
Gross weight | 1,24kg |
Customs tariff number | 85365019000 |
ECLASS | 27-37-12-38 Agreement switch |