EUCHNER – More than safety.
EUCHNER – More than safety.

CIT3PL1N30-STA (Order no. 071552)

Read-only head CIT3 with parallel interface, plugged in axially

  • Parallel interface
  • Cylindrical design M30
  • M12 plug connector
  • Axial connection
CIT3PL1N30-STA (Order no. 071552)

Description

Mounting instructions

On mounting the read head and data carrier, it is to be ensured the crossing direction as per the direction of the arrow on the active face of the read head is observed.

Attention:

On the use of a screened cable the connecting cable is allowed to be max. 50 m long.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1LED
1)Clear zone
2Active face
3Crossing direction
mCenter offset
sRead distance

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20

Operating and display elements

LED display Yellow: data carrier active

Electrical connection values

Output type Push-pull
Output voltage
0 ... 2 V DC for LOW level
UB - 3 ... UB V DC for HIGH level
Operating voltage DC 20 ... 24 ... 28 V DC (All the electrical connections must either be isolated from the mains supply by a safety transformer according IEC/ EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
Input voltage
max. 2 V DC SKIP input LOW level
min. 15 V DC SKIP input HIGH level
Switching current
per output -30 ... +30 mA
Current consumption
without load 65 ... 100 mA
Resistance 4.5 kΩ Input resistance

Mechanical values and environment

Connection type M12 plug, 8-pin, axial connection (The shield on the connecting cable is connected to the read head's housing via the knurled nut on the M12 plug connector.)
Mounting type surface
Degree of protection IP67
Ambient temperature 0 ... +50 °C
Material
Housing CuZn, nickel plated

Interface

Date interface 4-bit parallel, binary coded via HIGH/LOW level

In combination with data carrier CIS3P16D08KH16YSNOU, CIS3P16D08KH16YSNOP

Read distance 0 ... 5 ... 14 mm
Center offset
at 25 °C -6 ... 6 mm (Center offset mL in y direction (for sL = 5 mm))
at 25 °C -18 ... 18 mm (Center offset mL in x direction (for sL = 5 mm))

In combination with data carrier CIS3P35X16SH16YHNOU, CIS3P35X16SH16YHNOP, CIS3P35X16SH16YVNOU, CIS3P35X16SH16YVNOP

Read distance
at 21 °C 0 ... 7 ... 18 mm
Center offset
at 21 °C -23 ... 23 mm (Center offset mL in x direction (for sL = 7 mm))
at 21 °C -8 ... 8 mm (Center offset mL in y direction (for sL = 7 mm))

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 1,8 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 071552
Item designation CIT3PL1N30-STA
Gross weight 0,22kg
Customs tariff number 85389099990
ECLASS 27-28-04-01 Identification, RFID Reader

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.