Series RGBF...AM, 12 mm, mechanical
- With exterior diaphragm
- Plunger spacing 12 mm
- Upright housing according to DIN 43697
- Degree of protection IP67 according to IEC 60529
Description
Exterior diaphragm
The exterior diaphragm protects the plunger guide against the entry of very fine dust (dust from grinding, casting, glass, etc.) and prevents the plunger from seizing. At the same time, plunger sticking, caused by resinous lubricating coolants, can be prevented with this exterior diaphragm version.
Switching elements
ES 502 E | Snap-action switching contact 1 NC + 1 NO |
ES 514 | Snap-action switching contact 1 NC + 1 NO (on request) |
LED function display (on request)
LED function display possible on request.
Dimensional drawings
1 | Operating point |
2 | Free position |
3 | Groove for sealing ring |
4 | Number of plungers |
Connection examples
Connection examples
Technical data
Approvals
Electrical connection values
Connection cross section | 0.34 ... 1.5 mm² |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Utilization category | |
AC-12 | 8 A 250 V |
AC-15 | 6 A 230 V |
DC-13 | 6 A 24 V |
Short circuit protection according to IEC 60269-1 | 8A gG |
Switching current | |
min. at DC 12V | min. 10 mA |
thermal rated current Ith | 8 A |
Mechanical values and environment
Approach speed | 0.01 ... 20 m/min |
Connection type | |
4 x | M25 x 1.5 |
Number NC contacts | 4 |
Number of switching elements | 4 |
Number of NO contacts | 4 |
Design | upright, according to DIN 43697 |
Actuating element | Chisel plunger (Operating point accuracy ± 0.002. The reproducible operating point accuracy refers to the axial travel of the plunger after the switching element ES 502 E has been run-in with approx. 2,000 operating cycles.) |
Actuating force | min. 20 N |
Installation orientation | any |
Mechanical life | 30 x 10⁶ |
Switching principle | Snap-action switching contact (Contact closing time<4 ms contact bounce time<3 ms) |
Degree of protection | IP67 |
Plunger spacing | 12 mm |
Ambient temperature | -5 ... +80 °C |
Material | |
Contact | Silver alloy, gold flashed |
Housing | Die-cast aluminum, anodized |
Miscellaneous
Additional feature | (Exterior diaphragm = AM. The exterior diaphragm provides additional protection for the plunger guide. Plunger sticking, primarily caused by resinous lubricating coolants, can be prevented by this AM version.) |
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità
Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità
Mode d’emploi Boîtiers multipistes de précision RG, GS, GL 12/16 mm
Betriebsanleitung Präzisions-Reihengrenztaster RG, GS, GL 12/16 mm
Istruzioni di impiego Finecorsa multipli di precisione RG, GS, GL 12/16 mm
Other Documents
CAD data
Ordering data
Ordernumber | 082326 |
Item designation | RGBF04D12-502AM-M |
Gross weight | 0,817kg |
European Article Number (EAN) | 4047048002524 |
Customs tariff number | 85365019000 |
ECLASS | 27-27-06-02 Multi-position switch |