Contact expansion ESM-TE.., 3 safety contacts, 1 auxiliary contact, time-delay, cat. 3
- Use up to category 3 according to EN ISO 13849-1
- LED status indicators
- Control using safety relays
- 3 redundant time-delayed safety contacts
- Delay time range 1 s–30 s
- 1 auxiliary contact
- Earth fault/ground fault monitoring can be selected
Description
Relay outputs
The outputs are electrically decoupled and of redundant design.
Connection
By using suitable wiring the following function can be selected:
- Earth fault/ground fault monitoring to detect short circuits between the connecting cables and earth or ground and to shut down the outputs or prevent relay starting if necessary.
Time-delayed shutdown
The release time for the time-delay contacts can be set as required using a potentiometer on the safety relay.
Dimensional drawings
Connection examples
Technical data
Approvals
Mechanical values and environment
Housing material | |
Housing | Polyamide PA6.6 |
Weight | |
Net | 0,23 kg |
Ambient temperature | |
At UB = 24V AC | -15 ... 40 °C |
At UB = 24V DC | -15 ... 60 °C |
Degree of protection | IP20 |
Mechanical life | |
operating cycles | 10 x 106 |
Contact material | AgNi-10 |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Connection | Connection terminals |
Length of control cable | |
With conductor cross-section 0.75mm2 | 1000 m |
Safety contacts 17/18, 27/28, 37/38 | |
Number of safety contacts | 3 |
Auxiliary contacts S25/S26 | |
Number of auxiliary contacts | 1 |
Electrical connection ratings
Operating voltage | |
AC/DC | 24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.) |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | |
Leakage path/air gaps | 4 kV |
Overvoltage category according to IEC EN 60664-1 | 3 |
Reverse polarity protection | |
On version UB =24V DC | |
Connection rating | |
at 24V DC | 1,5 W |
Degree of contamination (external, according to EN 60947-1) | 2 |
Connection cross-section | 0,14 ... 2,5 mm² (Connection terminal (size)) |
Test voltage | |
Control system/contacts | 2,5 kV |
Control voltage | |
On S11 | 24 V |
Control current | |
S11...S14 | 40 mA |
LED indicator | 2 status displays (green) for relays K1 and K2 |
Auxiliary contacts S25/S26 | |
Type of output | |
NC | As monitoring contact for safety relay |
Switching characteristics | Auxiliary contacts with adjustable time-delay |
Safety contacts 17/18, 27/28, 37/38 | |
Type of output | |
NO | Relay contacts, positively driven (redundant) (Positively driven relay according to EN 50205) |
Switching voltage | |
DC | max.24 V |
AC | max.250 V |
Switching current | min.20 mA at 24V |
Cumulative current | max.10,5 A For all contacts (Also applies for UL) |
Fusing | |
External contact fuses (safety circuit) according to IEC 60269-1 | 10A gG |
Utilization category acc. to EN 60947-5-1 | |
AC-15 | 4A, 250V |
DC-13 | 2A, 24V |
AC-12 | 6A ohmic load, 250V |
DC-12 | 1.25A ohmic load, 24V |
Breaking capacity according to UL | 6A 250V AC / 2A 24V DC per contact |
Switching characteristics | Safety contacts with adjustable time-delay |
Delay time | |
Continuously adjustable | 1 ... 30 s |
Other
In compliance with | EN ISO 13849-1: 2015; EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015; EN 50581: 2012 (RoHS) |
Reliability values according to EN ISO 13849-1
Performance Level | PL d (This value is dependent on the number of switching cycles and the switching current.) |
Category | 3 (This value is dependent on the number of switching cycles and the switching current.) |
PFHD | 1.03 x 10-7 (This value is dependent on the number of switching cycles and the switching current.) |
Number of switching cycles | |
≤ 0.1 A at 24 V DC | max.400000 1/Jahr |
≤ 1 A at 24V DC | max.73000 1/Jahr |
≤ 2 A at 24 V DC | max.17000 1/Jahr |
Mission time | 20 y (This value is dependent on the number of switching cycles and the switching current.) |
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2090791
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001502
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Safety Contact Expansion ESM-TE3..
Doc. no.
Version
Language
Size
Operating Instructions Safety Contact Expansion ESM-TE3..
Mode d’emploi Extension de contacts de sécurité ESM-TE3..
Manual de instrucciones Ampliación de contactos de seguridad ESM-TE3..
Betriebsanleitung Sicherheits-Kontakterweiterung ESM-TE3..
Mode d’emploi Extension de contacts de sécurité ESM-TE3..
Manual de instrucciones Ampliación de contactos de seguridad ESM-TE3..
Betriebsanleitung Sicherheits-Kontakterweiterung ESM-TE3..
Doc. no.
2090075
Version
04/24
Language
Size
1,7 MB
Betriebsanleitung Sicherheits-Kontakterweiterung ESM-TE3..
Doc. no.
2090075
Version
04/24
Language
Size
0,7 MB
Other Documents
Approvals and certificates
CCC
Doc. no.
Version
Language
Size
CCC
Doc. no.
20001753
Version
Language
Size
0,0 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
1,0 MB
c UL us
Doc. no.
Version
Language
Size
0,2 MB
Ordering data
Ordernumber | 085617 |
Item designation | ESM-TE301 |
Gross weight | 0,205kg |
Customs tariff number | 85364110 |
ECLASS | 27-37-18-19 Device for monitoring of safety-related circuits |