TZ2LE024SEM4AS1 (Order no. 086990)

Safety switch TZ ASi, plug connector(s) M12

  • AS-Interface
  • Plug connector(s) M12, 4-pin
  • Auxiliary release
  • LED indicator
  • Actuating head fitted left
  • Open-circuit current principle
TZ2LE024SEM4AS1 (Order no. 086990)

Description

Approach direction

Horizontal

Can be adjusted in 90° steps

Guard locking principle

Operating current (power to lock): In the case of a safety guard with guard locking according to the open-circuit current principle, the safety guard is locked until the power supply to the guard locking solenoid is break-before-make. The guard is unlocked by spring force. This is also referred to as electrical guard locking.

Control of the guard locking solenoid

The guard locking solenoid is controlled via AS-Interface bit D0. In order to achieve safe control of the guard locking, the auxiliary voltage must also be switched safely.

auxiliary voltage

The ASi auxiliary voltage is required to supply the guard locking solenoid.

AS-Interface inputs

D0, D1

Positively driven contact 1

D2, D3

Positively driven contact 2

AS-Interface outputs

D0

Activating the guard locking

D1

LED red

D2

LED green

LED indicator

The Power LED indicates the operating voltage on the bus.

The Fault LED indicates when an error has been detected on the AS-Interface bus.

The green and red LEDs can be controlled by the control system via the bus as required using bits D1 and D2.

Auxiliary release

The auxiliary release on the front allows access to the machine in the event of a malfunction, e.g. a power failure. It is unlocked using a tool or a key. The auxiliary release must be secured against misuse (sealing, laking).

Required accessories

Actuator is not included in the scope of delivery.

Dimension drawing
Dimension drawing
Connector assignment
Connector assignment
Electromechanical safety switches in use

Dimensional drawings

Dimensional drawings
1Auxiliary release
2Plug connector not aligned
aTravel without operation: actuator is in the guide slot, but function is not triggered.
bSwitching operation completed. Actuator must be inserted to this point to ensure safe switching. The actuator must be withdrawn at least to point a for switching off.

Connection examples

Connection examples
View of plug side

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20DNV-GL_TAA0000172 Rev. 1DGUV_TZ_ET 24013_ET 24014CCC2024010305643586_SafetySwitch T_STc_UL_us_E155795_2/5Asi Interface_56201

Electrical connection values

ASI operating current max. 45 mA
AS-Interface auxiliary voltage 24 V -15 ... 10 %
Auxiliary current AS-Interface 350 mA
AS-Interface LED
green Power
red Fault
AS-Interface protocol ASi-3
ASI data out D0 = control of guard locking, D1 = red LED, D2 = green LED
ASI data in D0, D1 = door position, D2, D3 = guard locking
AS-Interface slave type ID-Code: B, EA-Code: 7
ASI voltage 22.5 ... 30 ... 31.6 V
Solenoid duty cycle 100 %

Mechanical values and environment

Approach speed max. 20 m/min
Approach direction
Actuating head left C
Connection type
1 x Plug connector M12 (4-pin)
Number of door position positively driven contacts
according to AS-i Safety at Work
Number of guard lock monitoring positively driven contacts
according to AS-i Safety at Work 1 D2,D3 (1 = locked)
Extraction force 30 N
Actuation frequency max. 1200 1/h
Actuating force 35 N
Installation orientation any
Insertion depth 52 mm
Mechanical life 1 x 10⁶
Retention force 10 N
Switching principle Slow-action switching contact
Degree of protection IP67
Ambient temperature -25 ... +55 °C
Material
Contact Silver alloy, gold flashed
Housing Anodized die-cast alloy
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Monitoring of the guard position3x10620 y
Important! Values valid at DC-13 100 mA/24V
Monitoring of guard locking3x10620 y
Important! Values valid at DC-13 100 mA/24V


In combination with actuator ACTUATOR-Z-G

Overtravel 4 mm

In combination with actuator ACTUATOR-Z-GN

Overtravel 16 mm

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 6,5 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 086990
Item designation TZ2LE024SEM4AS1
Gross weight 1,214kg
Customs tariff number 85365019000
ECLASS 27-27-26-03 Safety switch with guard control

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.