SN02D12-502-MC1856 (Order no. 089550)

Series SN... 12 mm, mechanical

  • Plunger spacing 12 mm
  • Upright housing, small flange
  • Degree of protection IP67 according to IEC 60529
SN02D12-502-MC1856 (Order no. 089550)

Description

Switching element

ES 502 E

Snap-action switching contact 1 NC + 1 NO

Dimension drawing
Dimension drawing
Wiring diagram ES 502 E
Wiring diagram ES 502 E
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1Cable 3x0.75, color code DIN 47100
2Operating point
3Free position
4Dog
5View of connection side
6Male Han Q5/0, degree of protection IP44
7Switching element: ES502E snap-action switching contact with 1 normally open and 1 normally closed contact. Double gap contacts, electrically isolated switching contacts.
8Housing without earth conductor!

Connection examples

Connection examples

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/6CCC_2020980305000540_CQC2008010305306206

Electrical connection values

Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 2 kV
Utilization category
AC-15 6 A 50 V
DC-13 6 A 24 V
Short circuit protection according to IEC 60269-1 8A gG
Switching current
min. at DC 12V min. 10 mA

Mechanical values and environment

Approach speed 0.01 ... 40 m/min
Connection type 1 x plug connector Han Q5/0 (Harting plug connector Han Q5/0, 5-pin; only pins 1, 3 and 4 used; with cable 3,000 mm (3x0.75 mm²). Mounted on right.)
Number NC contacts 2
Number of switching elements 2
Number of NO contacts 2
Design upright
Actuating element Chisel plunger
Actuating force min. 20 N
Installation orientation any
Mechanical life 30 x 10⁶
Contact bounce time < 3ms
Switching principle Snap-action switching contact
Operating point accuracy ± 0,002 (The reproducible operating point accuracy refers to the axial travel of the plunger after the switching element ES 502 E has been run-in with approx. 2,000 operating cycles.)
Contact closing time max. 4 ms
Degree of protection IP67 (only in the inserted state, with the related mating connector)
Plunger spacing 12 mm
Ambient temperature -5 ... +80 °C
Material
Contact Silver alloy, gold flashed
Housing Die-cast aluminum, anodized

Miscellaneous

C number
C1856
Additional information Housing without earth conductor! (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN IEC 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent insulation measures.)

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 2,0 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 089550
Item designation SN02D12-502-MC1856
Gross weight 0,578kg
Customs tariff number 85365019000
ECLASS 27-27-06-02 Multi-position switch

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.