EUCHNER – More than safety.
EUCHNER – More than safety.

ESM-BT401 (Order no. 090818)

Safety relay ESM-BT.., 4 safety contacts, time-delay, cat. 4

  • Use up to category 4 according to EN ISO 13849-1
  • LED status indicators
  • 1-channel or 2-channel control
  • 4 redundant safety contacts of which 3 contacts time-delayed
  • Delay time range 1 s–30 s
  • Short circuit and earth fault/ground fault monitoring
ESM-BT401 (Order no. 090818)

Description

Relay outputs

The outputs are electrically decoupled and of redundant design.

Connection options

By using suitable wiring, the following functions can be selected:

  • Relay start with automatic start, a start button or a monitored start button
  • Monitoring of downstream relays or contactors.
  • Simultaneity monitoring to monitor safety components over time
  • Relay start using a monitored start button
  • Short circuit monitoring to detect short circuits between the connecting cables and to shut down the outputs or prevent relay starting if necessary
  • Earth fault/ground fault monitoring to detect short circuits between the connecting cables and earth or ground and to shut down the outputs or prevent relay starting if necessary.

Time-delayed shutdown

The release time for the time-delay contacts can be set as required using a potentiometer on the safety relay.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_4/1CCC2024010305659956_ESM

Operating and display elements

LED display 4 status displays (green) for relays K1, K2, K3, K4

Electrical connection values

Drop-out delay at 24 V AC/ DC max. 20 ms Emergency stop
Power consumption
at 24 V DC 4.7 W
Power consumption (apparent power)
at 24 V AC 5.3 VA
Connection cross section 0.14 ... 2.5 mm² (Connection terminals (size))
Rated insulation voltage Ui 250 V
Rated supply frequency 50 ... 60 Hz
Rated impulse withstand voltage Uimp 4 kV
Operating voltage
AC/DC 24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent insulation measures.)
Test voltage
Control system/contacts 2.5 kV
Control voltage
on S11 18.6 ... 26 V
Control current 190 mA
Overvoltage category according to IEC EN 60664-1 3
Reverse polarity protection
On version UB = 24 V DC
Degree of contamination (external, according to EN 60947-1) 2

Mechanical values and environment

Connection type Connection terminals
Control cable length
with conductor cross-section 0.75 mm2 1000 m
Mechanical life
Operating cycles 10 x 10⁶
Mounting type TH 35 mounting rail (EN IEC 60715)
Degree of protection IP20
Ambient temperature -15 ... +40 °C
Material
Housing Polyamide PA6.6
Contact AgSnO2

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Number of switching cycles
≤ 2 A at 24 V DC max. 100000 1/y
≤ 1 A at 24 V DC max. 350000 1/y
≤ 0.1 A at 24 V DC max. 500000 1/y
Mission time 20 y (This value is dependent on the number of switching cycles and the switching current.)

Miscellaneous

in compliance with EN ISO 13849-1: 2015; EN 62061: 2005 + AC 2010 + A1: 2013 + A2: 2015; EN50581: 2012 (RoHS)

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 2,0 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 090818
Item designation ESM-BT401
Gross weight 0,254kg
Customs tariff number 85364110
ECLASS 27-37-18-19 Device for monitoring of safety-related circuits

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.