Safety relay ESM-BT.., 4 safety contacts, time-delay, cat. 4
- Use up to category 4 according to EN ISO 13849-1
- LED status indicators
- 1-channel or 2-channel control
- 4 redundant safety contacts of which 1 contact time-delayed
- Delay time range 1 s–30 s
- Short circuit and earth fault/ground fault monitoring
Description
Relay outputs
The outputs are electrically decoupled and of redundant design.
Connection options
By using suitable wiring, the following functions can be selected:
- Relay start with automatic start, a start button or a monitored start button
- Monitoring of downstream relays or contactors.
- Simultaneity monitoring to monitor safety components over time
- Relay start using a monitored start button
- Short circuit monitoring to detect short circuits between the connecting cables and to shut down the outputs or prevent relay starting if necessary
- Earth fault/ground fault monitoring to detect short circuits between the connecting cables and earth or ground and to shut down the outputs or prevent relay starting if necessary.
Time-delayed shutdown
The release time for the time-delay contacts can be set as required using a potentiometer on the safety relay.
Dimensional drawings
Connection examples
Technical data
Approvals
Mechanical values and environment
Housing material | |
Housing | Polyamide PA6.6 |
Weight | |
Net | 0,25 kg |
Ambient temperature | -15 ... 40 °C |
Degree of protection | IP20 |
Mechanical life | |
operating cycles | 10 x 106 |
Contact material | AgSnO2 |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Connection | Connection terminals |
Length of control cable | |
With conductor cross-section 0.75mm2 | 1000 m |
Safety contacts 13/14, 23/24, 33/34, 47/48 | |
Number of safety contacts | 4 |
Electrical connection ratings
Drop-out delay at 24V AC | max.20 ms Emergency stop |
Drop-out delay at 24V DC | max.30 ms Emergency stop |
Operating voltage | |
AC/DC | 24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.) |
Power consumption (apparent power) | |
At 24V AC | 5,3 VA |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | |
Leakage path/air gaps | 4 kV |
Overvoltage category according to IEC EN 60664-1 | 3 |
Reverse polarity protection | |
On version UB =24V DC | |
Rated supply frequency | 50 ... 60 Hz |
Connection rating | |
at 24V DC | 4,7 W |
Degree of contamination (external, according to EN 60947-1) | 2 |
Connection cross-section | 0,14 ... 2,5 mm² (Connection terminal (size)) |
Test voltage | |
Control system/contacts | 2,5 kV |
Control voltage | |
On S11 | 24 V 18,6 ... 26 V Start button |
Control current | 190 mA |
LED indicator | 4 status displays (green) for relays K1, K2, K3, K4 |
Safety contacts 13/14, 23/24, 33/34, 47/48 | |
Type of output | |
NO | Relay contacts positively driven (redundant) (Positively driven relay according to EN 50205) |
Switching voltage | |
AC | max.250 V |
DC | max.24 V |
Switching current | min.5 mA at 24V |
Cumulative current | max.15 A For all contacts (Cumulative current at an ambient temperature of T= 20° C: 9A ;T= 30° C: 3A ; T= 40° C: 1A. If these currents are exceeded, a spacing of 5 mm between the devices must be observed.) |
Fusing | |
External contact fuses (safety circuit) according to IEC 60269-1 | 10A gG |
Utilization category acc. to EN 60947-5-1 | |
AC-15 | 3A, 250V |
DC-13 | 3A, 24V |
AC-12 | 8A ohmic load, 250V (6 operating cycles/min.) |
DC-12 | 8A ohm resistive load, 40V (6 operating cycles/min.) |
Breaking capacity according to UL | 8A 250V AC / 3A 24V DC per contact |
Switching characteristics | 3 safety contacts non-delayed, 1 safety contact time-delayed (Contact switching behavior: n.d.: non-delayed d.: delayed) |
Delay time | |
Continuously adjustable | 1 ... 30 s |
Other
In compliance with | EN ISO 13849-1: 2015; EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015; EN 50581: 2012 (RoHS) |
Reliability values according to EN ISO 13849-1
Switching contacts time-delay | |
Category | 3 (This value is dependent on the number of switching cycles and the switching current.) |
Performance Level | PL e (This value is dependent on the number of switching cycles and the switching current.) |
PFHD | 8.84 x 10-8 (This value is dependent on the number of switching cycles and the switching current.) |
Switching contacts non-time-delay | |
Category | 4 (This value is dependent on the number of switching cycles and the switching current.) |
Performance Level | PL e (This value is dependent on the number of switching cycles and the switching current.) |
PFHD | 4.22 x 10-8 (This value is dependent on the number of switching cycles and the switching current.) |
Number of switching cycles | |
≤ 0.1 A at 24 V DC | 500000 1/Jahr |
≤ 1 A at 24 V DC | 300000 1/Jahr |
≤ 2 A at 24 V DC | 100000 1/Jahr |
Mission time | 20 y (This value is dependent on the number of switching cycles and the switching current.) |
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2090791
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001502
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Safety Relay ESM-BT4..
Doc. no.
Version
Language
Size
Operating Instructions Safety Relay ESM-BT4..
Mode d’emploi Unité de base ESM-BT4..
Manual de instrucciones Módulo básico ESM-BT4..
Betriebsanleitung Basisgerät ESM-BT4..
Mode d’emploi Unité de base ESM-BT4..
Manual de instrucciones Módulo básico ESM-BT4..
Betriebsanleitung Basisgerät ESM-BT4..
Doc. no.
2109074
Version
04/24
Language
Size
1,5 MB
Betriebsanleitung Basisgerät ESM-BT4..
Doc. no.
2109074
Version
04/24
Language
Size
0,4 MB
Other Documents
Approvals and certificates
CCC
Doc. no.
Version
Language
Size
CCC
Doc. no.
20001753
Version
Language
Size
0,0 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
1,0 MB
c UL us
Doc. no.
Version
Language
Size
0,2 MB
Ordering data
Ordernumber | 090820 |
Item designation | ESM-BT421 |
Gross weight | 0,253kg |
Customs tariff number | 85364110 |
ECLASS | 27-37-18-19 Device for monitoring of safety-related circuits |