NZ2WO-528L060 (Order no. 091279)

Safety switch NZ.WO, domed plunger, plug connector(s) M26 (SR6)

  • Rounded plunger
  • Version B according to EN 50041 (hardened)
  • Plug connector(s) M26 (SR6), 6-pin PE
  • 1 positively driven, positively driven contact
  • 1 NO contacts
  • LED indicator: AC/DC 12-60 V red
NZ2WO-528L060 (Order no. 091279)

Description

Approach direction

Horizontal and vertical

Can be adjusted in 90° steps

Switching element

528H

Slow-action switching contact 1 positively driven, positively driven contact 1 NO contact

LED indicator

The switch has a freely assignable LED indicator.

Dimension drawing
Dimension drawing
Wiring diagram 511
Wiring diagram 511
Travel diagram
Travel diagram
Electromechanical safety switches in use

Dimensional drawings

Dimensional drawings
1Operating point NO contact
2Operating point NC contact
3Free position

Connection examples

Connection examples

Shift travel diagrams

Shift travel diagrams
Contacts closed
Contacts open
Contacts positively driven

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20DNV-GL_TAA0000172 Rev. 1DGUV_NZ_ET 23025_ET 23026CCC2020980305000534_CQC2008010305306210_2024c_UL_us_E155795_2/4

Electrical connection values

Display module
AC/DC 12 ... 60 ... 60 V LED red
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2.5 kV
Utilization category
DC-13 4 A 24 V
AC-15 4 A 230 V
Short circuit protection according to IEC 60269-1 4A gG
Switching current
min. at DC 24V 1 mA
thermal rated current Ith 4 A

Mechanical values and environment

Approach speed 0.1 ... 10 m/min
Connection type
1 x Plug connector SR6 (6-pin + PE)
Number of NO contacts 1
Number of door position positively driven contacts 1
Actuating element Rounded plunger
Actuating force 15 ... 30 N
Installation orientation any
Mechanical life 30 x 10⁶
Switching principle Slow-action switching contact
Degree of protection IP65
Ambient temperature -25 ... +80 °C
Material
Contact Silver alloy, gold flashed
Housing Anodized die-cast alloy

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Safety position sensor2x10720 y
Important! Values valid at DC-13 100 mA/24V


Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 4,7 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 091279
Item designation NZ2WO-528L060
Gross weight 0,336kg
Customs tariff number 85365019000
ECLASS 27-27-26-01 Safety position switch (Type 1)

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.