Attention:
- The connecting cable to the control system is allowed to be max. 15 m long.
- On the use of a screened cable the connecting cable to the read head is allowed to be max. 15 m long.
- It is only ever possible to connect 1 read head per interface adapter.
Dimensional drawings
1 | Suitable for 35 mm mounting rail according to DIN 46277 |
Connection examples
Connection examples
Technical data
Operating and display elements
LED display | |
Yellow | ACTIVE LED data carrier active |
Green | STATE LED operational |
Electrical connection values
Connection cross section | 0.14 ... 2.5 mm² |
Output type | Push-pull |
Operating voltage DC | 20 ... 24 ... 28 V DC (All the electrical connections must either be isolated from the mains supply by a safety transformer according to IEC/EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)) |
Input voltage | |
0 ... 2 V DC Low signal (Reset,Skip) | |
15 ... Ub V DC High signal (Reset,Skip) | |
Switching voltage | |
Ub-3 ... Ub V (High signal (A,B,C,D,Strobe)) | |
0 ... 2 V (Low signal (A,B,C,D,Strobe)) | |
Switching current | |
per output | -30 ... +30 mA |
Current consumption | |
without load | 65 ... 100 mA |
Resistance | 4.5 kΩ for inputs (Reset,Skip) |
Mechanical values and environment
Connection type | plug-in screw terminal |
Number of read heads | max. 1 |
Mounting type | TH 35 mounting rail (EN IEC 60715) |
Ambient temperature | 0 ... +55 °C |
Material | |
Housing | PA6.6, gray |
Interface
Date interface | 4-bit binary coded + strobe |
In combination with read/write head CIT3ASX1N12ST and data carrier CIS3AP10D05KH01K, CIS3AP10D05KH01K-P
Read distance | |
with center offset m=0 | 0 ... 3 ... 6 mm (These values apply for the surface installation of the read head and flush installation of the data carrier in ferrous metals.) |
with center offset m=0 | 0 ... 3 ... 6.5 mm (These values apply for the surface installation of the read head and flush installation of the data carrier in non-metallic surroundings.) |
with center offset m=0 | 0 ... 3 ... 5 mm (These values apply for the surface installation of the read head and flush installation of the data carrier in aluminum.) |
Center offset | |
Read distance s = 3 mm | -2,5 ... 2,5 mm (These values apply for the surface installation of the read head and flush installation of the data carrier in non-metallic surroundings.) |
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2077155
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001517
Version
Language
Size
0,1 MB
Other Documents
Ordering data
Ordernumber | 091875 |
Item designation | CIA3PL1G08 |
Gross weight | 0,21kg |
Customs tariff number | 85364110 |
ECLASS | 27-28-04-01 Identification, RFID Reader |