EUCHNER – More than safety.
EUCHNER – More than safety.

HBAS-094594 (Order no. 094594)

Hand-held pendant station HBAS, EMERGENCY STOP device, enabling switch, pushbuttons, membrane keypad, programmable pulse generator, LC display

  • Programmable pulse generator
  • Tamper-proof EMERGENCY STOP device according to EN ISO 13850, dual-channel
  • Membrane keypad with 20 keys and 2 LEDs
  • LC display with LED background lighting, switchable 4-line/8-column or 8-line/16-column
  • RS422 interface, 3964R protocol
  • 1 enabling switch, 3-stage, 2 NO contacts
  • Coiled cable can be expanded to 3.5 m
HBAS-094594 (Order no. 094594)

Description

Notes

  • ActiveX module available for integrating the user’s application (for ActiveX capable user programs under MS Windows®)
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
Hand-held pendant stations and hand wheels

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00972/20c_UL_us_E206093_1/2

Operating and display elements

ItemColorExtrasSwitching elementNote slide-in labelSlide-in labelVersionNumberDesignation1LED
----Pulse generator1
----Display1
see data sheets---Membrane keys20
see data sheets---LED2
see data sheets--2 NO contact eachEnabling switch, 3-stage1
see data sheetsred-black with yellow plate-2 pos. driven contactsEmergency stop1

Electrical connection values

Connecting cable 23x0.14 mm²
Output type
Pulse generator RS422
Operating voltage DC 24 V DC -20% ... +20%
Utilization category
DC-13 Emergency stop 30 V / 3 A
Switching capacity (VA)
Enabling switch max. 0.25 VA
Switching voltage
Enabling switch max. AC/DC 42 V
Switching current
Enabling switch max. 100 mA
Current consumption max. 100 mA (without switched-on LEDs)

Mechanical values and environment

Connection type Plug connector (19-pin, metal version)
Cable length
coiled 3.5 m (extended)
Atmospheric humidity
Condensation not permissible max. 80 % rH
Shock and vibration resistance according to EN 60068-2-27/-2-6
Degree of protection
IP65 (on the front)
according to NEMA 250-12 (on the front)
Ambient temperature 0 ... +50 °C
Material Polycarbonate

Miscellaneous

Color
Housing Gray RAL 7040
The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures
Additional feature
Pulse generator (see manual)
Acoustic sensor (see manual)
Firmware update (see manual)

Interface

Data protocol 3964R, 8 data bits, even parity
Data rate 9.6 ... 19.2 kbit/s (automatic adjustment during initialization)
Date interface RS422

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 2,8 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 094594
Item designation HBAS-094594
Gross weight 1,206kg
Customs tariff number 85371098
ECLASS 27-33-02-02 Mobile Panel (HMI)

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.