Safety switch TK, cable entry M20 x 1.5
- 3 x cable entry M20 x 1.5
- Auxiliary release on the switch head
- Without prevention of inadvertent locking position (faulty closure protection)
- Guard locking pin right
- Closed-circuit current principle
Description
Guard locking principle
closed-circuit current (power to unlock): In a safety guard with guard locking according to the closed-circuit current principle, the guard is locked by spring force until the guard locking solenoid is supplied with current. The guard is unlocked by means of magnetic force. This is also referred to as mechanical guard locking.
Switching element
528 | Slow-action switching contact |
Contacts for guard locking: 1 positively driven, positively driven contact 1 NO contact |
Auxiliary release with triangular wedge
The auxiliary release on the switch head allows access to the machine in the event of a malfunction, e.g. a power failure. It is unlocked using a tool or a key. The auxiliary release must be secured against misuse (sealing, laking).
Contact separation
When actuated, the contacts are opened. The guard locking is not completely released. To prevent tampering, the contact separation must be sealed (e.g. with sealing lacquer).
Without prevention of inadvertent locking position (faulty closure protection)
The TK safety switch does not have a prevention of inadvertent locking position (faulty closure protection). This must be implemented separately.
Functional drawings
Dimensional drawings
1 | Auxiliary release on both sides |
2 | Contact separation |
Connection examples
Technical data
Approvals
Electrical connection values
Power consumption | 8 W |
Connection cross section | 0.34 ... 1.5 mm² |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Utilization category | |
DC-13 | 4 A 24 V |
AC-15 | 4 A 230 V |
Short circuit protection according to IEC 60269-1 | 4A gG |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Solenoid duty cycle | 100 % |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
thermal rated current Ith | 4 A |
Mechanical values and environment
Approach direction | A |
Connection type | |
3 x | M20 x 1.5 |
Number of guard lock monitoring NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 1 |
Actuation frequency | max. 1200 1/h |
Installation orientation | any |
Mechanical life | 1 x 10⁶ |
Switching principle | Slow-action switching contact |
Degree of protection | IP67 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Reinforced thermoplastic |
Contact | Silver alloy, gold flashed |
Locking force Fmax | 5000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | Mission time | |
---|---|---|
Monitoring of guard locking | 2x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V |
PL | Maximum SIL | Category | Mission time | |
---|---|---|---|---|
Control of guard locking | Depending on external control of guard locking | 20 y |
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità
Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità
Mode d’emploi Interrupteurs de sécurité TK…
Manual de instrucciones Interruptor de seguridad TK…
Betriebsanleitung Sicherheitsschalter TK…
Other Documents
CAD data
Ordering data
Ordernumber | 094652 |
Item designation | TK1-528AB024M |
Gross weight | 0,589kg |
Customs tariff number | 85365019000 |
ECLASS | 27-27-26-03 Safety switch with guard control |