Read head CET1-AX-..., M12, with guard locking and guard lock monitoring
- Read head with guard locking
- Locking force up to 6500 N
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M12
- 2 LEDs (1 freely configurable)
- Approach direction A (delivery state)
Description
Combination options
Suitable for connection to a CES-AZ evaluation unit
Solenoid operating voltage
- DC 24 V +10%, -15%
Guard locking type
CET1 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
LED function display
LED red | illuminates when solenoid is switched on |
LED green | freely configurable |
Category according to EN ISO 13849-1
Important: The category according to EN ISO 13849-1 depends on the evaluation unit used and on the installation orientation.
Notes
- Special connecting cables from EUCHNER are required for the connection. Please take into account in the order!
- The device may be operated only in conjunction with the actuator CET-A-.... The actuator must be ordered separately.
Auxiliary release
This is used for releasing the guard locking with the aid of a tool. The auxiliary release must be sealed to prevent tampering (for example with sealing lacquer).
Dimensional drawings
1 | Plug connector M12 8-pin, not aligned |
Connection examples
Technical data
Approvals
Electrical connection values
Power consumption | |
Solenoid | 11 W |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
LED | 24 V DC -15% ... +15% reverse polarity protected |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV |
Solenoid duty cycle | 100 % |
Safety class | III |
Current consumption | |
ICM | 450 mA Solenoid |
LED | max. 6 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | 1 plug connector M12, 8-pin |
Installation orientation | any |
Switching frequency | 1 Hz |
Degree of freedom X | ±5 mm |
Degree of freedom Y | ±5 mm |
Degree of freedom Z | ±4 mm |
Mechanical life | 2 x 10⁶ |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67 (with screwed tight plug connector) |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Safety switch | Die-cast aluminum |
Ramp | Stainless steel |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Guard locking principle | Closed-circuit current principle |
Accessories
AM-C-SW4-V3-161344
- Plastic inserts for hexagon socket screws a/f 4
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws
AM-C-SW5-V3-161348
- Plastic inserts for hexagon socket screws a/f 5
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Betriebsanleitung Lesekopf CET-AX mit Zuhaltung und Zuhaltungsüberwachung
Other Documents
CAD data
Ordering data
Ordernumber | 095735 |
Item designation | CET1-AX-LRA-00-50X-SA |
Gross weight | 1,247kg |
European Article Number (EAN) | 4047048005563 |
Customs tariff number | 85365019000 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |