EUCHNER – More than safety.
EUCHNER – More than safety.

RGBF04R12-502AMLE060-M (Order no. 096585)

Series RGBF...AM, 12 mm, mechanical

  • With exterior diaphragm
  • Plunger spacing 12 mm
  • Upright housing according to DIN 43697
  • Degree of protection IP67 according to IEC 60529
RGBF04R12-502AMLE060-M (Order no. 096585)

Description

Exterior diaphragm

The exterior diaphragm protects the plunger guide against the entry of very fine dust (dust from grinding, casting, glass, etc.) and prevents the plunger from seizing. At the same time, plunger sticking, caused by resinous lubricating coolants, can be prevented with this exterior diaphragm version.

Switching elements

ES 502 E

Snap-action switching contact 1 NC + 1 NO

ES 514

Snap-action switching contact 1 NC + 1 NO (on request)

LED function display

Function display is available for the following voltage range (see accessories)

LE060

12 ... 60 V AC/DC

Dimension drawing
Dimension drawing
Switching element
Switching element
Wiring diagram ES 502 E
Wiring diagram ES 502 E

Dimensional drawings

Dimensional drawings
1Operating point
2Free position
3Groove for sealing ring
4LED indicator
5Number of plungers

Connection examples

Connection examples

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/6CCC_2020980305000540_CQC2008010305306206

Electrical connection values

Connection cross section 0.34 ... 1.5 mm²
Display module
AC/DC 12 ... 60 ... 60 V LED
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2.5 kV
Utilization category
DC-13 6 A 24 V
AC-15 6 A 230 V
AC-12 8 A 250 V
Short circuit protection according to IEC 60269-1 8A gG
Switching current
min. at DC 12V min. 10 mA
thermal rated current Ith 8 A

Mechanical values and environment

Approach speed 0.01 ... 50 m/min
Connection type
4 x M25 x 1.5
Number NC contacts 4
Number of switching elements 4
Number of NO contacts 4
Design upright, according to DIN 43697
Actuating element
Slide bearing Roller plunger (d roller 5mm. Operating point accuracy ± 0.01. The reproducible operating point accuracy refers to the axial travel of the plunger after the switching element ES 502 E has been run-in with approx. 2,000 operating cycles.)
Actuating force min. 20 N
Installation orientation any
Mechanical life 30 x 10⁶
Switching principle Snap-action switching contact (Contact closing time<4 ms contact bounce time<3 ms)
Degree of protection IP67
Plunger spacing 12 mm
Ambient temperature -5 ... +80 °C
Material
Contact Silver alloy, gold flashed
Housing Die-cast aluminum, anodized

Miscellaneous

Additional feature (Exterior diaphragm = AM. The exterior diaphragm provides additional protection for the plunger guide. Plunger sticking, primarily caused by resinous lubricating coolants, can be prevented by this AM version.)

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 2,1 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 096585
Item designation RGBF04R12-502AMLE060-M
Gross weight 0,873kg
European Article Number (EAN) 4047048005389
Customs tariff number 85365019000
ECLASS 27-27-06-02 Multi-position switch

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.