Non-contact safety switch CES-AR-C01...
- Safety switch with integrated evaluation electronics
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- Multicode

Description
Approach direction
Can be adjusted in 90° steps
Short circuit monitoring
The switch generates its own clock signal on the output lines OA/OB. Pay attention to this aspect when connecting to control systems and relays.
Multicode evaluation
Every suitable actuator is detected by the switch.
Category according to EN 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Additional connections
OUT | Monitoring output (semiconductor) |
RST | Reset input |
Typical actuating range
With actuators CES-A-BBA and CES-A-BCA

For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered.
With actuator CES-A-BPA

For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.
Connector assignment


Dimensional drawings

1 | LED status indication |
2 | Active face |
Connection examples

Technical data
Approvals


Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Electrical connection values
Fuse | |
external (operating voltage) | 0.25 ... 8 A |
Rated insulation voltage Ui | 75 V (Tested up to 75 V by employers' liability insurance association) |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
Turn-on time | |
Safety outputs | max. 400 ms |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3 | max. 260 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
Safety class | III |
Current consumption | |
no load on outputs | max. 50 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OUT | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8 x UB ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
Switching current | max. 200 mA |
Safety outputs OA / OB | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
LOW U(OA,OB) | 0 ... 1 V DC |
HIGH U(OA,OB) | UB-1.5 ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
rated conditional short-circuit current | max. 100 A |
Discrepancy time | max. 10 ms |
Utilization category | |
DC-13 | 24 V 400 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output | 1 ... 400 mA |
Test pulse duration | max. 1 ms |
Mechanical values and environment
Connection type | M12 plug connector, 8-pin |
Tightening torque | |
Fixing screws | max. 1 Nm |
Ready delay | 10 s |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Mounting distance | min. 40 mm |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Plastic, PBT |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | - | 2.1x10-9 | 4 | 20 y |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
In combination with actuator CES-A-BPA-098775
Switch-on distance | 22 mm (on surface mounting on aluminum. In a non-metallic environment, the typical operating distances increase to 30 mm) |
Secured switch-off distance sar | max. 58 mm |
Secured switching distance sao | min. 18 mm |
Switching hysteresis | 1 ... 2 mm |
In combination with actuator CES-A-BBA-071840
Switch-on distance | 18 mm |
Secured switch-off distance sar | max. 45 mm (The values apply to surface mounting) |
Secured switching distance sao | min. 15 mm (The values apply to surface mounting) |
Switching hysteresis | 1 ... 3 mm (The values apply to surface mounting) |
In combination with actuator CES-A-BDA-18-156935
Switch-on distance | 19 mm (The values apply to surface mounting) |
Secured switch-off distance sar | max. 45 mm (The values apply to surface mounting) |
Secured switching distance sao | min. 10 mm (The values apply to surface mounting) |
Switching hysteresis | 1 ... 3 mm (The values apply to surface mounting) |
In combination with actuator CES-A-BRN-100251
Switch-on distance | 27 mm |
Secured switch-off distance sar | max. 75 mm |
Secured switching distance sao | min. 20 mm (The values apply to surface mounting of the actuator on steel.) |
Switching hysteresis | 3 mm (The values apply to surface mounting of the actuator on steel.) |
Accessories

AC-YD-V0,2-SBB-111696
- For series connection of AR/BR safety switches in switch chains without IO-Link evaluation
- Y-distributor M12 with connecting cable, 2 x 5-pin, 1 x 8-pin
- Straight plug connector
- PVC cable
- Cable length 0.2 m

AC-YD-V1,0-SBB-112395
- For series connection of AR/BR safety switches in switch chains without IO-Link evaluation
- Y-distributor M12 with connecting cable, 2 x 5-pin, 1 x 8-pin
- Straight plug connector
- PVC cable
- Cable length 1 m
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents











Other Documents




CAD data
Ordering data
Ordernumber | 098942 |
Item designation | CES-AR-C01-CH-SA |
Gross weight | 0,191kg |
Customs tariff number | 85365019000 |
ECLASS | 27-27-24-03 Safety-related transponder switch |