Evaluation unit CMS-E-ER, 2 safety contacts, 1 auxiliary contact, 1 feedback loop can be connected
- Up to 30 read heads can be connected
- 2 safety contacts
- 1 auxiliary contact
- 1 feedback loop can be connected
- Start automatic/monitored/not monitored
Description
Functional description
The evaluation unit CMS-E-ER is suitable for the direct connection of up to 30 read heads.
Category/PL according to EN ISO 13849-1
- Category 4/PL e with only one read head connected
- Max. category 3/PL d with more than one read head connected
Notice:
At low approach speeds in the z direction, the time offset when switching the reed contacts must not be more than 0.6 ms.
Dimensional drawings
Connection examples
Technical data
Approvals
Operating and display elements
LED display | 1 indicator LED Power (UB) and 2 status indicators for the read heads (K1/K2) |
Electrical connection values
Fuse | |||||||||||||
Protection internal (operating voltage UB) | 0.75 A Automatically resetting fuse PTC | ||||||||||||
External contact fuse (safety circuit) acc. to EN IEC 60269-1 | 4A gG | ||||||||||||
Connection cross section | 0.14 ... 2.5 mm² | Outputs | |||||||||||
| |||||||||||||
Rated insulation voltage Ui | 250 V | ||||||||||||
Operating voltage | |||||||||||||
AC/DC | -10% ... 24 ... +10% V (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent insulation measures.) | ||||||||||||
Utilization category | |||||||||||||
DC-13 | 1.5A, 24V (Max. switching current per contact) | ||||||||||||
AC-15 | 0.9A , 240V and 0.9A , 24V (Max. switching current per contact) | ||||||||||||
AC-1 | 3A, 230V; 3A, 24V (Max. switching current per contact) | ||||||||||||
Risk time according to EN 60947-5-3 | max. 20 ms | ||||||||||||
Switching load | |||||||||||||
According to UL class 2 | Input: 24 V AC/DC; output: 30 V AC, 24 V DC | ||||||||||||
Switching capacity (VA) | |||||||||||||
Safety contacts 13/14, 23/24 | max. 720 VA | ||||||||||||
Switching voltage | |||||||||||||
Safety contacts 13/14, 23/24 | max. AC 240 V | ||||||||||||
Switching current | |||||||||||||
Safety contacts 13/14, 23/24 | 10 ... 3000 mA at DC 24 V | ||||||||||||
Auxiliary contacts 31/32 | max. 1500 mA at DC 24 V | ||||||||||||
Current consumption | |||||||||||||
at DC 24 V | 10 ... 110 mA | ||||||||||||
Degree of contamination (external, according to EN 60947-1) | 2 |
Mechanical values and environment
Approach direction | Z (If the approach speed is low, the approach direction Z should be avoided.) |
Connection type | Connection terminals |
Mechanical life | 10 x 10⁶ |
Mounting type | TH 35 mounting rail (EN IEC 60715) |
Degree of protection | Terminals IP20 / housing IP40 |
Ambient temperature | 0 ... +55 °C |
Material | |
Housing | Polyamide PA6.6 |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Number of switching cycles | |
≤ 0.1 A at 24 V DC | 166000 1/y |
≤ 1 A at 24 V DC | 70000 1/y |
Mission time | 20 y (This value is dependent on the number of switching cycles and the switching current.) |
Monitoring of the guard position with 1 read head | |
Category | 4 (This value is dependent on the number of switching cycles and the switching current.) |
Performance Level | PL e (This value is dependent on the number of switching cycles and the switching current.) |
PFHD | 2.5 x 10-8 (This value is dependent on the number of switching cycles and the switching current.) |
Monitoring of the guard position with>1 read head | |
Category | 3 (This value is dependent on the number of switching cycles and the switching current.) |
Performance Level | PL d (This value depends on the number of switching cycles and the switching current. applies to protected wiring. With unprotected wiring and if more than one door than one door has to be opened with frequency or if the wiring is unprotected and more than more than 5 doors are connected in series, the following applies: Performance Level = PL c, PFHD = 1.1E-6. See EN ISO 14119:2014, section 8.6 and ISO TR 24119. diagnostic coverage according to ISO TR 24119 must result in at least the value 'low' in order to achieve PL d is achieved.) |
PFHD | 1.0 x 10-7 (This value depends on the number of switching cycles and the switching current. This value applies to protected wiring. With unprotected wiring and if more than one door than one door has to be opened with frequency or with unprotected wiring and if more than more than 5 doors are connected in series, the following applies: Performance Level = PL c, PFHD = 1.1E-6. See EN ISO 14119:2014, section 8.6 and ISO TR 24119. diagnostic coverage in accordance with ISO TR 24119 must be at least 'low' in order to achieve PL d is achieved) |
Miscellaneous
in compliance with | EN ISO 13849-1: 2015; EN ISO 13849-2:2012; EN 50178: 1997; EN 60204-1: 2006/A1: 2009; EN ISO 13850: 2015; EN 14119:2013; EN 6100-6-2: 2005; EN 6100-6-3: 2007/A1: 2011; EN 60947-5-3: 2013 |
In combination with read head CMS-R-AXH-03V, CMS-R-AXH-05V, CMS-R-AXH-SC, CMS-R-AXH-05P and actuator CMS-M-AC
Secured switch-off distance sar | max. 31 mm (The assured release distance sar corresponds to the reset distance.) |
Secured switching distance sao | |
with center offset m=0 | min. 6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
Center offset | |
at s=3 mm read distance | 2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
In combination with read head CMS-R-CXC-03V, CMS-R-CXC-05V, CMS-R-CXC-05P, CMS-R-CXC-SC and actuator CMS-M-CA
Secured switch-off distance sar | max. 14 mm (The assured release distance sar corresponds to the reset distance.) |
Secured switching distance sao | |
with center offset m=0 | min. 6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
Center offset | |
at s=3 mm read distance | 2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
In combination with read head CMS-RH-BYB-03VL, CMS-RH-BYB-05VL and actuator CMS-MH-BB
Secured switch-off distance sar | max. 13 mm (The assured release distance sar corresponds to the reset distance.) |
Secured switching distance sao | |
with center offset m=0 | min. 6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
Center offset | |
at s=3 mm read distance | 2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
In combination with read head CMS-R-BXI-03V, CMS-R-BXI-05V, CMS-R-BXI-SC, CMS-R-BXI-07P and actuator CMS-M-BD
Secured switch-off distance sar | max. 12 mm (The assured release distance sar corresponds to the reset distance.) |
Secured switching distance sao | |
with center offset m=0 | min. 3 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
Center offset | |
at s=3 mm read distance | 2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
In combination with read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and actuator CMS-M-EF
Secured switch-off distance sar | max. 17 mm (The assured release distance sar corresponds to the reset distance.) |
Secured switching distance sao | |
with center offset m=0 | min. 6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
Center offset | |
at s=3 mm read distance | 2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
In combination with read head CMS-RH-AYA-03VL, CMS-RH-AYA-05VL and actuator CMS-MH-AA
Secured switch-off distance sar | max. 20 mm (The assured release distance sar corresponds to the reset distance.) |
Secured switching distance sao | |
with center offset m=0 | min. 10 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
Center offset | |
at s=3 mm read distance | 2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
Accessories
CMS read heads
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2112987
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001569
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Evaluation Unit CMS-E-ER
Doc. no.
Version
Language
Size
Operating Instructions Evaluation Unit CMS-E-ER
Mode d’emploi Analyseur CMS-E-ER
Manual de instrucciones Unidad de evaluación CMS-E-ER
Betriebsanleitung Auswertegerät CMS-E-ER
Mode d’emploi Analyseur CMS-E-ER
Manual de instrucciones Unidad de evaluación CMS-E-ER
Betriebsanleitung Auswertegerät CMS-E-ER
Doc. no.
2102344
Version
12-11/23
Language
Size
2,1 MB
Betriebsanleitung Auswertegerät CMS-E-ER
Doc. no.
2102344
Version
12-11/23
Language
Size
0,6 MB
Other Documents
Approvals and certificates
TUEV Sued Italia
Doc. no.
Version
Language
Size
TUEV Sued Italia
Doc. no.
Version
Language
Size
4,5 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
1,0 MB
Sales documents
Interrupteurs de sécurité à codage magnétique CMS
Doc. no.
Version
Language
Size
Interrupteurs de sécurité à codage magnétique CMS
Doc. no.
090606
Version
10-11/20
Language
Size
5,8 MB
CAD data
Ordering data
Ordernumber | 099182 |
Item designation | CMS-E-ER |
Gross weight | 0,225kg |
Customs tariff number | 85364110 |
ECLASS | 27-27-24-02 Safety-related magnetic proximity switch |