Read heads CMS, design B - with NO contact combinations, M8
- In combination with evaluation unit CMS-E-AR
- Cube-shaped version, 36 x 26 mm
- NO contacts wired in parallel
- With plug connector M8
Description
Dimensional drawings
1 | Actuator |
2 | Active face |
3 | Center offset m at s=3 mm |
4 | Sao |
5 | Assured operating distance |
Connection examples
Technical data
Approvals
Workspace
Secured switch-off distance sar | max. 17 mm (The assured release distance s_ar corresponds to the reset distance.) |
Secured switching distance sao | |
with center offset m=0 | min. 6 mm (Value applies only if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
Repeat accuracy R | max. 10 % |
Electrical connection values
Rated insulation voltage Ui | 26.4 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Switching voltage | |
DC | 24 V |
Switching voltage according to UL | |
according to UL Class 2 | max. 24 V DC |
Switching current | 8 ... 500 mA |
Switching characteristics | parallel |
Mechanical values and environment
Connection type | 4-pin M8 plug connector |
Number of NO contacts | 3 NO contacts |
Tightening torque | 0.4 ... 0.5 Nm |
Design | B |
Installation orientation | any |
Mechanical life | 100 x 10⁶ |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67 |
Ambient temperature | -20 ... +60 °C |
Material | |
Housing | Fiber glass reinforced PPS |
Method of operation | magnetic, reed contact |
Miscellaneous
in compliance with | EN ISO 13849-1:2015; EN 50178:1997; EN 60204-1:2006/A1:2009; EN ISO 14119:2013; EN 61000-6-2:2005; EN 61000-6-3:2007/A1:2011; EN 60947-5-3:2013 |
permissible actuators | CMS-M-BH |
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2112987
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001569
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Read Heads/Actuators for Evaluation Units CMS
Doc. no.
Version
Language
Size
Operating Instructions Read Heads/Actuators for Evaluation Units CMS
Mode d’emploi Têtes de lecture / actionneurs pour analyseurs CMS
Manual de instrucciones Cabezas de lectura/actuadores para unidades de evaluación CMS
Betriebsanleitung Leseköpfe/Betätiger für Auswertegeräte CMS
Mode d’emploi Têtes de lecture / actionneurs pour analyseurs CMS
Manual de instrucciones Cabezas de lectura/actuadores para unidades de evaluación CMS
Betriebsanleitung Leseköpfe/Betätiger für Auswertegeräte CMS
Doc. no.
2102384
Version
09-11/23
Language
Size
2,8 MB
Betriebsanleitung Leseköpfe/Betätiger für Auswertegeräte CMS
Doc. no.
2102384
Version
09-11/23
Language
Size
0,7 MB
Other Documents
Approvals and certificates
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
1,0 MB
Sales documents
Interrupteurs de sécurité à codage magnétique CMS
Doc. no.
Version
Language
Size
Interrupteurs de sécurité à codage magnétique CMS
Doc. no.
090606
Version
10-11/20
Language
Size
5,8 MB
Ordering data
Ordernumber | 100755 |
Item designation | CMS-R-BXO-SC |
Gross weight | 0,041kg |
Customs tariff number | 85389099990 |
ECLASS | 27-27-24-02 Safety-related magnetic proximity switch |