Bus module MGB-B...-PN... with 3 controls and indicators, push-pull plug
- 1 cover for indicators
- 1 operating mode selector
- 1 illuminated pushbuttons
- including adhesive labels
- Push-pull plug
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
![MGB-B-A1W2A2-PN-105287 (Order no. 105287)](https://assets2.euchner.de/files/46/84/ast_664684_xl.png)
Description
Profinet connection
Connection via push-pull plugs according to IEC 61076-3-117
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.
![Dimension drawing](https://assets2.euchner.de/files/06/33/ast_640633_m.png)
![](https://assets2.euchner.de/files/85/00/738500_m.png)
![](https://assets2.euchner.de/files/85/11/738511_m.png)
![](https://assets2.euchner.de/files/85/23/738523_m.png)
![](https://assets2.euchner.de/files/84/85/738485_m.png)
![](https://assets2.euchner.de/files/84/72/738472_m.png)
![](https://assets2.euchner.de/files/85/14/738514_m.png)
Dimensional drawings
![Dimensional drawings](https://assets2.euchner.de/files/06/33/ast_640633.png)
Technical data
Approvals
![TUEV Süd München_M6A 040393 0042 Rev. 00](https://assets2.euchner.de/files/82/70/ast_628270_m.png)
![c_UL_us_E155795_3/9](https://assets2.euchner.de/files/82/74/ast_628274_m.png)
![ProfiNET_Z10142_Version 2023](https://assets2.euchner.de/files/07/48/ast_630748_m.png)
![EAC_RU C-DE.HX37.B.14157/20](https://assets2.euchner.de/files/06/97/ast_630697_m.png)
Operating and display elements
Occupancy diagram | B2 |
Item | Color | Extras | Switching element | Note slide-in label | Slide-in label | Version | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
11 | Red | Cover for indicators | |||||||
12 | white | 1NO | Illuminated pushbutton | ||||||
13 | Code 2 of 3 | Entsichert / Unsecured ; Sonderfunktion / Special function ; Gesichert Zentral / Secured Central | Operating mode selector |
Electrical connection values
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
maximum feed-in current in the connection block | |
X1, X2 | max. 4000 mA |
Safety class | III |
Current consumption | max. 500 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Power supply X1 | |
Fuse | |
external | min. 1 A slow blow |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Mechanical values and environment
Connection type | |
Push-pull power (X2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) | |
Push-pull power (X1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) | |
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 (X3 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) |
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 (X4 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) |
Installation orientation | any |
Switching frequency | 0.25 Hz |
Response time | |
Operating mode selector | max. 220 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP54 |
Ambient temperature | |
at UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Diagnostic Coverage (DC) | 99 % |
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Safe multi-position switch | PL e | 3 | 4.1x10-8 | 4 | 20 y |
Miscellaneous
Slide-in label | ||||||||||||||||
| ||||||||||||||||
Product version number | V3.23.3 |
Interface
Bus data protocol | Profinet (IEC 61158 type 10) |
Safety data protocol | Profisafe (IEC 61784-3-3) |
Date interface | |
Ethernet |
Accessories
ZSA
ZSA, 3-stage, with cable and plug connector RC12
![ZSA092141C2038](https://assets2.euchner.de/files/78/01/ast_737801_xs.png)
092141
ZSA092141C2038
ZSA092141C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 5 m
- Direct connection to safety switch
![ZSA097567C2038](https://assets2.euchner.de/files/78/01/ast_737801_xs.png)
097567
ZSA097567C2038
ZSA097567C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 10 m
- Direct connection to safety switch
![ZSA099495C2038](https://assets2.euchner.de/files/78/01/ast_737801_xs.png)
099495
ZSA099495C2038
ZSA099495C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 15 m
- Direct connection to safety switch
![ZSA100873C2038](https://assets2.euchner.de/files/78/01/ast_737801_xs.png)
100873
ZSA100873C2038
ZSA100873C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 25 m
- Direct connection to safety switch
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
![Doc. no. EDC2123624](https://assets2.euchner.de/files/24/39/ast_2962439_thumb.jpg)
EU-Konformitätserklärung
Doc. no.
EDC2123624
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
![Doc. no. EDC20001506](https://assets2.euchner.de/files/59/72/ast_2305972_thumb.jpg)
UKCA-Konformitätserklärung
Doc. no.
EDC20001506
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type A
Doc. no.
Version
Language
Size
![Doc. no. 2114575](https://assets2.euchner.de/files/67/15/ast_3186715_thumb.jpg)
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type A
Doc. no.
2114575
Version
03/24
Language
Size
3,4 MB
![Doc. no. 2114575](https://assets2.euchner.de/files/90/68/ast_3179068_thumb.jpg)
Betriebsanleitung Sicherheitssysteme MGB-L..B-PN.-… (PROFINET) und mit Datenstruktur Typ A
Doc. no.
2114575
Version
03/24
Language
Size
3,4 MB
Other Documents
Approvals and certificates
ProfiNET
Doc. no.
Version
Language
Size
![Doc. no.](https://assets2.euchner.de/files/47/89/ast_2924789_thumb.jpg)
ProfiNET
Doc. no.
Version
Language
Size
0,1 MB
TUEV Süd München
Doc. no.
Version
Language
Size
![Doc. no.](https://assets2.euchner.de/files/34/48/ast_1193448_thumb.jpg)
TUEV Süd München
Doc. no.
Version
Language
Size
4,0 MB
TUEV Süd München M6A Zertifikat
Doc. no.
Version
Language
Size
![Doc. no.](https://assets2.euchner.de/files/34/88/ast_1163488_thumb.jpg)
TUEV Süd München M6A Zertifikat
Doc. no.
Version
Language
Size
0,3 MB
c UL us
Doc. no.
Version
Language
Size
![Doc. no.](https://assets2.euchner.de/files/11/09/ast_2001109_thumb.jpg)
c UL us
Doc. no.
Version
Language
Size
0,7 MB
CAD data
Ordering data
Ordernumber | 105287 |
Item designation | MGB-B-A1W2A2-PN-105287 |
Gross weight | 2,28kg |
Customs tariff number | 85371098 |
ECLASS | 27-24-26-07 Field bus, decentralized peripheral - basic device |