EUCHNER – More than safety.
EUCHNER – More than safety.

ZSM2300-106670 (Order no. 106670)

ZSM, LED, + and - buttons, vibration motor, reset button, plug connector HAN Q17

  • 3-stage function
  • Vibration signal
  • LED indicator
  • Reset button ©
  • + and – buttons
  • Coiled connecting cable, 3.1 m
  • Plug connector
ZSM2300-106670 (Order no. 106670)

Description

3-stage function

Enabling function is active only in the second stage (center position, actuating point). If the pushbutton is released or pushed further (panic function), the enabling is removed (dependent on the wiring, see function sequence).

Vibration signal

The vibration signal is used for tactile feedback of the enabling position.

LED indicator

The LED indicator is used for visual feedback directly at the enabling switch.

Reset button ©

Button for reset function directly from the enabling switch.

+ and – buttons

These pushbuttons can be configured individually. For example, for moving axes in the positive or negative direction.

Cable

The high-quality connecting cables are available in a coiled version.

Dimension drawing
Dimension drawing
Connector assignment
Connector assignment
Function sequence
Function sequence
Switching element
Switching element
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Connection examples

Connection examples

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00972/20c_UL_us_E206093_4/1

Operating and display elements

ItemColorExtrasSlide-in labelSwitching elementNote slide-in labelVersionNumberDesignation1LED
Vibration motor1
- button1
LED red/green1
BlueLabeled pushbutton1
+ button1

Electrical connection values

Connecting cable 18x0.25 mm²
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Utilization category
DC-13 24 V 0.01 A (For additional indicators)
DC-13 24 V 0.3 A (For additional controls)
DC-13 30 V 0.1 A (For enabling switch, caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Short circuit protection according to IEC 60269-1 2A gG (In case of operating voltages other than 24 V, the short circuit protection must be dimensioned accordingly and checked.)
Switching characteristics 3-stage enabling switch
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Connection type Plug connector number of pins 17 + PE
Number of changeover contacts 3 (Connection as per block diagram)
Cable length
coiled, short straight piece of cable on the enabling switch 3.1 m
Mechanical life 1 x 10⁶
Switching principle Snap-action contact element
Degree of protection IP54
Ambient temperature -5 ... +60 °C
Material PA, CR, TPE (Low PAH)

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Enabling switch
B10D 0.1 x 10⁶

Miscellaneous

in compliance with 60947-5-8

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 4,1 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 106670
Item designation ZSM2300-106670
Gross weight 1,222kg
Customs tariff number 85371098
ECLASS 27-37-12-38 Agreement switch

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.