Safety switch TP-BI, plug connector M12, with door monitoring contact
- Auxiliary release on the front
- With door monitoring contact
- Bistable guard locking
- Increased horizontal overtravel
- Plug connector

Description
Approach direction

Horizontal and vertical
Can be adjusted in 90° steps
Increased overtravel for horizontal approach direction
Solenoid operating voltage
- AC/DC 24 V +10%, -15%
Guard locking type
TP‑BI | Guard locking operated by means of input signal. |
This type of guard locking has a function to prevent
- persons from unintentionally locking themselves inside if the safety door is open in case of a power failure or if the machine is switched off.
- the deactivation of the activated guard locking in case of a power failure.
Switching element
4141 | Slow-action switching contact 2 NC |
Auxiliary release
This is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
Functional drawings

Dimensional drawings

1 | Actuator |
2 | Auxiliary release |
3 | Locking screw |
4 | Pin 9 operating voltage 0 V, pin 10 control voltage +24 V (US), pin 11 operating voltage +24 V (UB) |
5 | Plug connector |
6 | Plug connector not aligned |
Connection examples

![]() | Door monitoring |
![]() | Solenoid monitoring |
Technical data
Approvals


Electrical connection values
Power consumption | 8 W |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Utilization category | |
DC-13 | 1 A 24 V |
AC-15 | 1 A 24 V |
Short circuit protection according to IEC 60269-1 | 1A gG |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Solenoid duty cycle | 100 % |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
thermal rated current Ith | 1 A |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | |
1 x | Plug connection M12 (12-pin) |
Number of door position positively driven contacts | 2 |
Number of guard lock monitoring positively driven contacts | 2 |
Extraction force | 20 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 10 N |
Installation orientation | any |
Mechanical life | 1 x 10⁶ |
Retention force | 10 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP67 |
Ambient temperature | -20 ... +55 °C |
Material | |
Contact | Silver alloy, gold flashed |
Housing | Reinforced thermoplastic |
Locking force Fmax | 1300 N |
Locking force FZh | 1000 N |
Guard locking principle | BiState |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Control of guard locking | PL b | - | 4.23x10-6 | b | 20 y |
B10D | Mission time | |
---|---|---|
Monitoring of the guard position | 3x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V | ||
Monitoring of guard locking | 3x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V |
In combination with actuator ACTUATOR-P-GNT
Horizontal overtravel | 7 mm |
In combination with actuator ACTUATOR-P-GT
Horizontal overtravel | 2 mm |
Vertical overtravel | 1.5 mm |
Accessories

AE-K-A1-DULK1-84177
- Lock unique locking
- Key removable in “unlocked” and “locked” positions

AE-K-A1-IULK1-86236
- Identical locking
- Key removable in “unlocked” and “locked” positions

AE-K-A1-IUK2-109212
- Identical locking
- Key can be removed only in “unlocked” position

AE-K-A1-ILK1-121917
- Identical locking
- Key removable in “locked” position

AE-B-A1-02,0-096230
- Can be used as escape release or emergency release
- no automatic return
- Sheath length 2 m (rope length 6 m)

AE-B-A1-02,0-F-097747
- Can be used as escape release or emergency release
- automatic return
- Sheath length 2 m (rope length 6 m)

AE-B-A1-03,0-098313
- Can be used as escape release or emergency release
- no automatic return
- Sheath length 3 m (rope length 6 m)

AE-B-A1-04,0-098314
- Can be used as escape release or emergency release
- no automatic return
- Sheath length 4 m (rope length 6 m)

AE-B-A1-03,0-F-111233
- Can be used as escape release or emergency release
- automatic return
- Sheath length 3 m (rope length 6 m)

AE-B-A1-06,0-125582
- Can be used as escape release or emergency release
- no automatic return
- Rope length 6 m (without sheath)

AE-B-A1-06,0-F-124770
- Can be used as escape release or emergency release
- automatic return
- Rope length 6 m (without sheath)

RIEGEL 0 NP/TP OHNE RASTUNG
- Bolt for safety switch NP... and TP...A
- Steel bolt
- For doors hinged on the left or right
- Suitable for a door gap of approx. 6 mm

RIEGEL 1 NP/TP 1X RASTUNG ZU
- Bolt for safety switch NP...AS,TP...A and GP
- Steel bolt
- For doors hinged on the left or right
- Suitable for a door gap of approx. 15 mm
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents



Mode d’emploi Interrupteur de sécurité TP-BI…
Betriebsanleitung Sicherheitsschalter TP-BI…
Istruzioni di impiego Finecorsa di sicurezza TP-BI…


Other Documents









Ordering data
Ordernumber | 109408 |
Item designation | TP-BI-3-4141A024SM12 |
Gross weight | 0,479kg |
Customs tariff number | 85365019000 |
ECLASS | 27-27-26-03 Safety switch with guard control |