Bolt for safety switch CES-C01
- Bolt for switch CES-C01
- Steel bolt
- For doors hinged on the left or right
- Ball detent mechanism in closed position
- Suitable for a door gap of approx. 15 mm
- Protective plate for safety switch
Description
Scope of delivery
- Safety switch CES-AP-C01-CH-SB-106798 pre-assembled
- CES actuator pre-assembled in bolt tongue
- Protective plate for safety switch pre-assembled
Latching in closed position
Bolt latches in closed position and prevents unintentional opening of the bolt. Ball or spring detent mechanisms are opened by overcoming the spring force.
Door types and door hinges
Suitable for hinged or sliding doors Suitable for doors hinged on the left and right With door stop, door cannot be opened inwards.
Protective plate
The protective plate protects the switch against damage.
Integrated lockout bar
With the aid of the integrated lockout bar, the bolt can be secured in the open position, e.g. using padlocks. It is possible to prevent people from being locked in the danger area unintentionally.
Dimensional drawings
1 | Screw secured against loosening |
2 | detent mechanism against accidental opening (vibration) |
3 | Safety guard frame (40x40) |
4 | Door hinged on the right |
5 | Door hinged on the left |
6 | Protective plate mounted on switch bracket. |
7 | Safety switch mounted on switch bracket. |
8 | Stop plate |
Technical data
Mechanical values and environment
Approach direction | A or C |
Number of safety switches that can be mounted | 1 |
Escape release | yes |
Material | |
Switch bracket | Steel powder-coated |
Handle | Plastic |
Guide strips | Plastic |
Base plate | Galvanized steel |
Miscellaneous
Detent mechanism closed position | Ball detent mechanism |
Switch CES-AP-C01-CH-SB-106798 (Order no. 106798)
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Electrical connection values
Fuse | |
external (operating voltage) | 0.25 ... 8 A |
Rated insulation voltage Ui | 300 V (Tested by the employers’ liability insurance association up to 75 V.) |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
Turn-on time | |
Safety outputs | max. 400 ms |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3 | max. 260 ms |
Safety class | III |
Current consumption | |
no load on outputs | max. 50 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output DIA | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8 x UB ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
Switching current | max. 200 mA |
Safety outputs OA / OB | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
LOW U(OA,OB) | 0 ... 1 V DC |
HIGH U(OA,OB) | UB-1.5 ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
rated conditional short-circuit current | max. 100 A |
Discrepancy time | max. 10 ms |
Utilization category | |
DC-13 | 24 V 400 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output | 1 ... 400 mA |
Test pulse duration | max. 0.4 ms |
Mechanical values and environment
Connection type | M12 plug connector, 5-pin |
Tightening torque | |
Fixing screws | max. 1 Nm |
Ready delay | 0.5 s |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Mounting distance | min. 40 mm |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Plastic, PBT |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Information de sécurité pour verrous-targettes
Información de seguridad para cerrojos
Sicherheitsinformation für Riegel
Other Documents
CAD data
Ordering data
Ordernumber | 110355 |
Item designation | RIEGEL CES-AC-AP-C01-CH-SB-110355 |
Gross weight | 2,233kg |
Customs tariff number | 83014090000 |