Non-contact safety switch CES-AH-C03-...
- Safety switch with integrated evaluation electronics
- Load currents of 4 A can be switched directly
- 2 safety outputs (semiconductor outputs)
- Category 3 / PL d according to EN ISO 13849-1
- With connecting cable PUR, 0.5 m, with plug connector AMP Super Seal, 1x3-pin/1x4-pin
- Approach direction C (not adjustable)
- Unicode

Description
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.
Only the last actuator taught-in is detected.
Category according to EN ISO 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 3 / PL d according to EN ISO 13849-1
Each safety path is independently safe.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |


Dimensional drawings

1 | PUR |
2 | PVC |
3 | Active face |
4 | Cable length 500 millimeters |
5 | LED status indication |
6 | View of connection side |
Connection examples

Technical data
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Operating and display elements
LED display | 2 STATE (green) and DIA (red) |
Electrical connection values
Fuse | |
external (operating voltage, +LA and +LB) | 0.25 ... 10 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB | 9 ... 32 V DC reverse polarity protected, regulated, residual ripple<5% |
Turn-on time | |
Safety outputs LA / LB | max. 400 ms |
EMC protection requirements | as per DIN EN 13309 |
Risk time according to EN 60947-5-3 | max. 250 ms |
Safety class | III |
Current consumption | |
no load on outputs | max. 150 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Time delay | |
In the fault state | 5 s (The switch remains in the fault state for this time before a reset is performed.) |
Power supply outputs | |
Power supply output load | |
U(+LA)/U(+LB) | 9 ... 32 V DC (Power supply same UB, same ground potential.) |
Pulse frequency | |
Power supply for load via PWM | max. 1 kHz |
Duty cycle Ton | |
Power supply for load via PWM | 0.1 ... 1 |
Safety output +LA/LA, +LB/LB | |
Output type | Semiconductor output, p-switching, short circuit-proof |
Output voltage | |
HIGH U(LA/LB) | U(+LA/+LB) - 1.5 ... U(+LA/+LB) V DC (Values at a switching current of 4 A without taking into account the cable lengths.) |
LOW U(LA/LB) | 0 ... 4 V DC |
rated conditional short-circuit current | max. 100 A |
Discrepancy time | max. 50 ms |
Utilization category | |
DC-13 | 24 V 4 A (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Off-state current Ir | max. 0.5 mA |
Switching current | 30 ... 4000 mA |
Test pulse duration | max. 6 ms (With series connection, the value increases according to the number of switches used.) |
Test pulse interval | min. 10000 ms |
Start input | |
Input voltage | |
HIGH | 8 ... UB V DC |
LOW | 0 ... 2 V DC |
Mechanical values and environment
Dimensions | 40 x 40 x 168 |
Connection type | Connecting cable PUR, 0.5 m, with plug connector AMP Super Seal, 1x3-pin / 1x4-pin |
Tightening torque | |
Fixing screws | max. 1 Nm |
Ready delay | max. 3 s (After the operating voltage is switched on, the semiconductor outputs are switched off during the ready delay.) |
Static bending radius | 10 x cable diameter |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Mounting distance | |
between switches | min. 80 mm |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65/IP67 |
Ambient temperature | -25 ... +70 °C |
Dwell time | min. 0.5 s (The dwell time of an actuator inside and outside the actuating range must be at least 0.5 s to ensure safe detection of internal faults in the evaluation unit (self-monitoring).) |
Material | |
Housing | Plastic, PBT |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL d | - | 1.03x10-7 | 3 | 20 y |
In combination with actuator CES-A-BRN-100251
Actuator distance s | |
for side approach | min. 6 mm (Minimum distance to prevent switching on in the side lobe of the read head.) |
Switch-on distance | 32 mm |
Secured switch-off distance sar | max. 75 mm |
Secured switching distance sao | min. 27 mm (The values apply to surface mounting of the actuator on steel.) |
Switching hysteresis | 3 mm (The values apply to surface mounting of the actuator on steel.) |
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size

EU-Konformitätserklärung
Doc. no.
EDC2127387
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size

UKCA-Konformitätserklärung
Doc. no.
EDC20001500
Version
Language
Size
0,1 MB
Other Documents
Sales documents
Flexibel sicher - Transpondercodierte Sicherheitssysteme CES
Doc. no.
Version
Language
Size

Flexibel sicher - Transpondercodierte Sicherheitssysteme CES
Doc. no.
119922
Version
06-06/22
Language
Size
8,4 MB
Ordering data
Ordernumber | 110370 |
Item designation | CES-AH-C03-AE-LS-110370 |
Gross weight | 0,7kg |
Customs tariff number | 85365019000 |
ECLASS | 27-27-24-03 Safety-related transponder switch |