EUCHNER – More than safety.
EUCHNER – More than safety.

CET3-AP-CRA-AH-50F-SI-114073 (Order no. 114073)

Non-contact safety switch CET-AP-..., with escape release, for connection to decentralized peripheral systems

  • Safety switch with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Direct connection to decentralized peripheral systems (e.g. ET200pro)
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • Unicode
  • Indication of the door position by LED
  • Escape release, 75 mm long
  • Approach direction A (delivery state)
CET3-AP-CRA-AH-50F-SI-114073 (Order no. 114073)

Description

Approach direction

Horizontal

Can be adjusted in 90° steps

Safety switch

The device may be operated only in conjunction with the actuator CET-A-....

Important: The actuator must be ordered separately.

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.

Solenoid operating voltage

  • DC 24 V +10%, -15%

Guard locking type

CET3

Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid.

LED function display

State LED

Status LED

DIA LED

Diagnostics LED

LED 1 rd

illuminates when the solenoid is energized

LED 2 gn

illuminates when door is closed

Category according to EN ISO 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1
  • The stated safety characteristics apply to any installation orientations of the safety switch.

Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

Escape release

This is used for manual release of guard locking from the danger zone without tools.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
Wiring diagram
Wiring diagram
CET: Transponder-coded safety switch with guard locking in use
CET3-AP: Mounting emergency release safety swith CET3-AP
CET3-AP: Mounting and Setup CET3-AP (closed-circuit current principle)
CET3-AP: Mounting auxiliary release with key CET3-AP

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/8

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection values

Fuse
external (operating voltage UB) 0.25 ... 8 A
external (solenoid operating voltage UCM) 0.5 ... 8 A
Power consumption
Solenoid 11 W
Connecting cable 30V DC, 2A (for UL requirement UL category code (CYJV/CYJV7))
Operating voltage DC
UB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
LED 24 V DC -15% V DC ... +10% V DC
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24 V 200 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UCM 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 400 ms
Switching load
according to UL 24V DC, Class 2 (For alternatives, see operating instructions)
Safety class III
Current consumption
ICM 450 mA
IB 80 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Degree of contamination (external, according to EN 60947-1) 3
Safety outputs OA / OB
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(OA,OB) 0 ... 1 V DC
HIGH U(OA,OB) UB-1.5V ... UB V DC
Discrepancy time
both safety outputs max. 10 ms
Turn-on time 400 ms
Off-state current Ir max. 0.25 mA
Risk time according to EN 60947-5-3
Single device
Switching current
per safety output OA / OB 1 ... 200 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 2 plug connector M12, 5-pin
Ready delay 1 s
Installation orientation any
Switching frequency max. 0.5 Hz
Degree of freedom X ±5 mm
Degree of freedom Y ±5 mm
Degree of freedom Z ±4 mm
Mechanical life 2 x 10⁶
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67 (screwed tight plug connector/mating component)
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Safety switch housing Die-cast aluminum
Ramp Stainless steel
Locking force Fmax 6500 N
Locking force FZh 5000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of guard lockingPL e-3.1x10-9420 y


PLMaximum SILCategoryMission time
Control of guard lockingDepending on external control of guard locking20 y


Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 9,8 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 114073
Item designation CET3-AP-CRA-AH-50F-SI-114073
Gross weight 1,349kg
European Article Number (EAN) 4047048006898
Customs tariff number 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.