STP3A-4131A024-10C-DCXC1993 (Order no. 114485)

Safety switch STP with door monitoring contact, plug connector MR10

  • Actuating head made of metal
  • Escape release from the rear
  • With door monitoring contact
  • Plug connector MR10
STP3A-4131A024-10C-DCXC1993 (Order no. 114485)

Description

Approach direction

Horizontal and vertical

Can be adjusted in 90° steps

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%

Guard locking type

STP3

Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid.

Switching element

4131

Slow-action switching contact 2 NC + 1 NO + 1 NO (door monitoring contact)

Escape release (C1993, long actuator shaft)

This is used for manual release of guard locking from the danger zone without tools. With identification of On/Off position.

Switching function
Switching function
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
Wiring diagram 4131
Wiring diagram 4131
Electromechanical safety switches in use

Functional drawings

Functional drawings

Dimensional drawings

Dimensional drawings
1Escape release (basic position)
2Unlocked

Connection examples

Connection examples

Connection examples

Connection examples
Door monitoring
Solenoid monitoring

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20CCC2024010305643586_SafetySwitch T_ST

Electrical connection values

Power consumption 8 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 2.5 kV
Utilization category
AC-15 4 A 50 V
DC-13 4 A 24 V
Short circuit protection according to IEC 60269-1 4A gG
Solenoid operating voltage
AC/DC 24 V -15% ... +10%
Solenoid duty cycle 100 %
Switching voltage
min. at 10 mA 12 V
Switching current
min. at 24 V 1 mA
thermal rated current Ith 4 A

Mechanical values and environment

Approach speed max. 20 m/min
Approach direction A
Connection type
1 x Plug connector BHA10 (9-pin + PE (not connected))
Number of door position NO contacts 1
Number of guard lock monitoring NO contacts 1
Number of guard lock monitoring positively driven contacts 2
Extraction force 30 N
Actuation frequency max. 1200 1/h
Actuating force 35 N
Installation orientation any
Insertion depth 24.5 mm
Mechanical life 1 x 10⁶
Retention force 20 N
Switching principle Slow-action switching contact
Degree of protection IP65
Ambient temperature -20 ... +55 °C
Material
Contact Silver alloy, gold flashed
Housing Reinforced thermoplastic
Locking force Fmax 2500 N
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Monitoring of the guard position5x10620 y
Important! Values valid at DC-13 100 mA/24V
Monitoring of guard locking5x10620 y
Important! Values valid at DC-13 100 mA/24V


PLMaximum SILCategoryMission time
Control of guard lockingDepending on external control of guard locking20 y


Miscellaneous

C number
C1993 Escape release long
Additional feature high cover, without auxiliary release

In combination with actuator ACTUATOR-S-GT-SN

Overtravel 5 mm

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 8,7 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 114485
Item designation STP3A-4131A024-10C-DCXC1993
Gross weight 0,616kg
Customs tariff number 85365019000
ECLASS 27-27-26-03 Safety switch with guard control

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.