Non-contact safety switches CES-I-AR-.-C04-…, flying lead
- Safety switch with integrated evaluation electronics
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
- Connecting cable PUR, 10 m, flying lead, 8-core
- Unicode
Description
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.
Category according to EN 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Terminal assignment
Designation | Function | Connecting cable conductor coloring |
---|---|---|
FI1B | Enable input for channel 2 | WH |
UB | Power supply, DC 24 V | BN |
FO1A | Safety output, channel 1 | GN |
FO1B | Safety output, channel 2 | YE |
OD | Monitoring output | GY |
FI1A | Enable input for channel 1 | PK |
0 V | Ground, DC 0 V | BU |
RST | Reset input | RD |
Dimensional drawings
1 | Active face |
2 | LED status indication |
3 | With rubber support |
Connection examples
Technical data
Approvals
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Electrical connection values
Fuse | |
external (operating voltage) | 0.25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB | 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV |
Turn-on time | |
Safety outputs | max. 400 ms |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3 | max. 260 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
Safety class | III |
Current consumption | max. 35 mA (without taking into account the load currents on the monitoring output and the safety outputs) |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OD | |
Output type | Semiconductor output, p-switching, short circuit-proof |
Output voltage | 0.8 x UB ... UB V DC |
Switching current | max. 50 mA |
Safety outputs FO1A / FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
rated conditional short-circuit current | 100 A |
Discrepancy time | max. 10 ms |
Utilization category | |
DC-13 | 24 V 200 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output | 1 ... 200 mA |
Test pulse duration | max. 1.0 ms (Applies to a load with C<= 30 nF and R<= 20 kohm) |
Test pulse interval | min. 140 ms |
Mechanical values and environment
Connection type | Connecting cable PUR, length 10 m |
Tightening torque | |
Fixing screws | max. 0.8 Nm |
Ready delay | 10 s |
Dynamic bending radius | 10 x cable diameter |
Static bending radius | 5 x cable diameter |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Mounting distance | |
between switches | min. 80 mm |
Mounting type | non-flush on metal |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67 |
Cable ambient temperature (dynamic) | -25 ... +65 °C |
Cable ambient temperature (static) | -30 ... +65 °C |
Material | |
Rubber support | NBR 80 ±5 Shore |
Housing | Plastic, PBT |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | - | 4.1x10-9 | 4 | 20 y |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
Additional feature | Rubber support included |
In combination with actuator CES-A-BBN-161502
Switch-on distance | |
Installation position C + D | 20 (10 mm bei -30°C) mm |
Installation position A + B | 25 (13 mm bei -30°C) mm |
Secured switch-off distance sar | |
in x/z direction / installation position A + B | max. 69 (auch bei -30°C) mm |
in x-/z direction / installation position C + D | max. 64 (auch bei -30°C) mm |
in y direction / installation position A + B | max. 77 (auch bei -30°C) mm |
in y direction / installation position C + D | max. 72 (auch bei -30°C) mm |
Secured switching distance sao | |
Installation position A + B | min. 15 (9,5 mm bei -30°C) mm |
Installation position C + D | min. 10 (4,5 mm bei -30°C) mm |
Switching hysteresis | |
Installation position C + D | 1 ... 2 mm (at -30 °C as well) |
Installation position A + B | 1 ... 2 mm (at -30 °C as well) |
In combination with actuator CES-A-BDN-06-104730
Switch-on distance | |
Installation position A or B (front side) | 19 mm |
Installation position C or D (broad side) | 15 mm |
Secured switch-off distance sar | |
in y direction | max. 60 mm |
in x/z direction | max. 40 mm |
Secured switching distance sao | |
Installation position C or D (broad side) | min. 10 mm |
Installation position A or B (front side) | min. 14 mm |
Switching hysteresis | 1 ... 2 mm |
In combination with actuator CES-A-BBN-C04-115271, CES-A-BBN-C04-EX-137527
Switch-on distance | |
Installation position A or B (front side) | 15 mm |
Installation position C or D (broad side) | 11 mm |
Secured switch-off distance sar | |
in y direction | max. 60 mm |
in x/z direction | max. 40 mm |
Secured switching distance sao | |
Installation position A or B (front side) | 10 mm |
Installation position C or D (broad side) | 6 mm |
Switching hysteresis | 1 ... 2 mm |
In combination with actuator CES-A-BDN-06-161742
Switch-on distance | |
Installation position C | 20 (14 mm bei -30°C) mm |
Installation position A | 25 (17 mm bei -30°C) mm |
Secured switch-off distance sar | |
Installation position C | max. 72 (auch bei -30°C) mm |
Installation position A | max. 77 (auch bei -30°C) mm |
Secured switching distance sao | |
Installation position C | min. 10 (4,5 mm bei -30°C) mm |
Installation position A | min. 15 (10,5 mm bei -30°C) mm |
Switching hysteresis | 1 ... 2 mm (at -30 °C as well) |
Accessories
CES-A-BBN-C04-115271
- Cube-shaped design 42 x 25 mm
- Two safety screws M4x20 and rubber support included
CES-A-BBN-161502
- Cube-shaped design 42 x 25 mm, height 12 mm
- Transponder with large actuating range
- Mounting compatible with actuators: CES-A-BBA-071840, CES-BBN-106600, CES-A-BBN-C04-115271
- Two safety screws M4x14 included
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Other Documents
Ordering data
Ordernumber | 119471 |
Item designation | CES-I-AR-U-C04-U10-119471 |
Gross weight | 0,389kg |
Customs tariff number | 85365019000 |
ECLASS | 27-27-24-03 Safety-related transponder switch |