EUCHNER – More than safety.
EUCHNER – More than safety.
 

RGBF04X12-732L-MC2409 (Order no. 120136)

Series RGBF... 12 mm, inductive

  • Proximity switch spacing 12 mm
  • Upright housing according to DIN 43697
  • Degree of protection IP67 according to IEC 60529
  • LED function display
RGBF04X12-732L-MC2409 (Order no. 120136)

Description

LED function display

DC and AC switching elements are equipped as standard with a function display on the switching element (yellow). The function display can be seen from the exterior.

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing
Connector assignment
Connector assignment
Switching element DC NO contact, PNP777, l1 = 12 mm779, l1 = 16 mm
Switching element DC NO contact, PNP777, l1 = 12 mm779, l1 = 16 mm
Switching element ES732/4C1997 or ES732/2C1997
Switching element ES732/4C1997 or ES732/2C1997
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1Actuator
2Assured operating distance
3Station
4Switching element
5Ident no.
6n Number of stations
7Type
8Length

Dimensional drawings

Dimensional drawings
1Ground strap connection:
- Polish the mounting surface

Connection examples

Connection examples
1brown
2white
3Blue
4black
5gray, not leading
6without earth conductor
75-pin

Connection examples

Connection examples

Connection examples

Connection examples

Connection examples

Connection examples
1Station
2Wiring diagram
LED for the NO contact function illuminates on actuation / LED for the NC function illuminates if not actuated

Technical data

Approvals

c_UL_us_E155795_3/6

Workspace

Rated operating distances Sn 5 mm
Assured operating distances Sa 0 ... 4 mm (Dimension applies only to steel (ST37) and to EUCHNER trip dogs of series UX.. / GX..)
Switching hysteresis 0.2 ... 1.0 mm (When installed)
Repeat accuracy R
according to EN 60947-5-2 max. 5 %
Switching element, station 1, station 3
Center offset
At s = 4 mm mOFF= (-) 0.5 mm and mON= 0.0 (For side approach)
At s = 1 mm mOFF= (-) 4.2 mm and mON= (-) 4.0 (For side approach)
At s = 3 mm mOFF= (-) 2.5 mm and mON= (-) 2.0 (For side approach)
At s = 2 mm mOFF= (-) 3.3 mm and mON= (-) 3.0 (For side approach)
Switching element, station 2, station 4
Center offset
At s = 2 mm mON= (-) 3.3 mm and mOFF= (-) 3.0 (For side approach)
At s = 1 mm mON= (-) 4.2 mm and mOFF= (-) 4.0 (For side approach)
At s = 3 mm mON= (-) 2.5 mm and mOFF= (-) 2.0 (For side approach)
At s = 4 mm mON= (-) 0.5 mm and mOFF= 0.0 (For side approach)

Operating and display elements

LED display
LED yellow LED forward current I Fmax. 2.5 mA

Electrical connection values

Output type PNP
Rated operating current Ie 250 mA
Operating voltage
DC 20 ... 24 ... 33 V Power supply unit with electrical isolation as per EN 61558-2-6 or sensor pulsing UB(HIGH)
Operating current max. 5 mA Current consumption without load
EMC protection requirements EN 60947-5-2
Utilization category
DC-12 250mA, 33V (For DC-13, the output must be protected with a free-wheeling diode for inductive loads.)
Short circuit and overload protection, pulsed yes
LOW level
on sensor pulsing 0 ... 5 V DC
Off-state current Ir max. 0.001 mA
Residual ripple
From UBor UB(HIGH) max. 10 %
Electrical switching frequency max. 500 Hz
Safety class III
Voltage drop Ud
DC max. 2.5 V
Duty cycle Ton
T (HIGH) : T (LOW) on sensor pulsing 4 : 1
Test pulse duration
T (LOW) on sensor pulsing 0.1 ... 20 ms
Reverse polarity protection yes

Mechanical values and environment

Connection type 2 x plug connector M12 (5-pin, straight plug connector: cable outlet not adjustable.)
Number NC contacts 2
Number of switching elements 4
Number of NO contacts 2
Design upright
Proximity switch spacing 12 mm
Degree of protection IP67 (only screwed tight with the related mating connector.)
Ambient temperature -25 ... +70 °C
Material
Housing Die-cast aluminum
Active face PBT

Miscellaneous

C number
C2409
Additional information Housing without earth conductor! (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN IEC 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent insulation measures.)

Ordering data

Ordernumber 120136
Item designation RGBF04X12-732L-MC2409
Gross weight 0,843kg
Customs tariff number 85365019000
ECLASS 27-27-06-02 Multi-position switch

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.