EUCHNER – More than safety.
EUCHNER – More than safety.

MSC-CE-FM4-121293 (Order no. 121293)

Expansion module MSC-CE

  • Input expansion
  • 12 single-channel / 6 dual-channel inputs
  • Compact housing with width of only 22.5mm
  • Simple diagnostics via LED displays
  • Suitable for connecting 4 pressure-sensitive mats
MSC-CE-FM4-121293 (Order no. 121293)

Description

Inputs and outputs

  • 12 single-channel/6 dual-channel inputs

  • 8 test outputs for monitoring for short circuits and overload states

Scope of delivery

  • The expansion plug (order no. 121308) is included with the expansion module

Accessories

  • Plug-in screw terminals (order no. 121321) must be ordered separately

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
MSC: Safe control system MSC

Dimensional drawings

Dimensional drawings
1Page A
2Page B

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20TUEV Süd München_Z10 040393 0030 Rev.01c_UL_us_E353660_UL_us_E467239

Electrical connection values

Connection cross section 0.5 ... 2.5 mm² (Screw terminal)
Outputs
NumberTypeFunctionFootnote
8Semiconductor outputs, p-switchingTest outputs(according to EN 61131-2)
Operating voltage DC
UB 24 V DC -20% ... +20% PELV (according to EN 60204-1)
Inputs
NumberTypeFunctionFootnote
12Semiconductor inputs, p-switchingSafety inputs(according to EN 61131-2)
2Semiconductor inputs, p-switchingfor node selection('Type2' according to EN61131-2)
Test pulse duration
Test outputs 0.2 ms
Overvoltage category according to IEC EN 60664-1 II
Power dissipation max. 3 W
Degree of contamination according to EN 60664-1 2

Mechanical values and environment

Dimensions 108 x 22.5 x 114.5 (Including screw terminals)
Connection type Plug-in screw terminal (Terminals not included)
Storage temperature -20 ... +85 °C
Cable length max. 100 m (with length above 50 m, cross-section>use 1 mm²)
Atmospheric humidity 10 ... 95 % rH
Mounting type TH 35 mounting rail (EN IEC 60715)
Degree of protection IP20
Ambient temperature -10 ... +55 °C
Material
Housing Polyamide

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y (according to ISO 13849-1:2006/IEC 62061:2005)
Category 4 (according to ISO 13849-1:2006/IEC 62061:2005)
Performance Level PL e (according to ISO 13849-1:2006/IEC 62061:2005)
PFHD 5.60E-09 1/h (according to IEC 61508:2010)
SIL CL 3

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 60,3 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 121293
Item designation MSC-CE-FM4-121293
Gross weight 0,217kg
Customs tariff number 85364110
ECLASS 27-24-22-05 SPS-Funktions-/Technologie-Modul

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.