Filter module AC-FM-AR
- Suitable for the connection of switchgear with OSSD outputs
- The filter module smoothens the test pulses
Description
- The test pulses of safety inputs FI1A and FI1B are filtered out at the outputs FO1A* and FO1B* to such an extent that the downstream control system can no longer detect them.
- Owing to smoothing of the test pulses, short circuit monitoring will no longer be effective at safety inputs FI1A / FI1B downstream of the filter module. Ruling out short circuits downstream of safety outputs FO1A* / FO1B* requires laying the cables with protection or mounting them in the same control cabinet as the control system.
- The filter module does not have its own safety characteristic (PL or category), because it is not connected to an external power supply. It therefore does not contribute to the failure probability.
Dimensional drawings
Connection examples
Technical data
Electrical connection values
Connection cross section | 0.08 ... 2.5 mm² |
Connection cross section AWG | 28 ... 14 AWG |
Output voltage | |
HIGH(1) | min. 10 V DC |
LOW(0) | max. 3 V DC |
Input voltage | 16 ... 26 V DC |
Switch-on delay | 0.003 s |
Switching load | min. 3 kΩ |
Test pulse duration | max. 1 ms (Max. permissible duration of the test pulses at the inputs) |
Mechanical values and environment
Stripping length | 5 mm |
Dimensions | 7 x 63 x 91 mm |
Connection type | Spring terminal |
Degree of protection | IP20 |
Ambient temperature | 0 ... +60 °C |
Material | |
Housing | PA 6.6 |
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2531837
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001499
Version
Language
Size
0,1 MB
Other Documents
Sales documents
Ordering data
Ordernumber | 127460 |
Item designation | AC-FM-AR-127460 |
Gross weight | 0,03kg |
Customs tariff number | 85389099990 |