Locking set MGB-L1...-EI (guard locking by spring force) with 3 pushbuttons
- Guard locking with guard lock monitoring
- 3 illuminated pushbuttons
- Connection via M12 plug
- Pre-assembled on mounting plates
- Unicode
Description
Ethernet/IP connection
M12 plug (a-coded) 4-pin according to IEC 61076-2-101
Integrated switch
Point-to-point topology network structure due to integrated switch.
Flexible use as interlocking or guard locking
By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring).
Dimensional drawings
Connection examples
Technical data
Approvals
Handle modules MGB-H-AA1A6-R-111838 (Order no. 111838)
Mechanical values and environment
Installation orientation | Door hinge DIN right |
Degree of protection | IP65 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Miscellaneous
Product version number | V3.0.0 |
Additional feature | with mounting plate and automatic lockout mechanism |
Sets MGB-L1B-EIA-R-128331 (Order no. 128331)
Workspace
Secured switch-off distance sar | |
Door position | max. 65 mm |
Operating and display elements
Occupancy diagram | |
L1 | |
B1 |
Item | Color | Extras | Switching element | Slide-in label | Note slide-in label | Version | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
90 | 1NO | Illuminated pushbutton | |||||||
91 | 1NO | Illuminated pushbutton | |||||||
92 | 1NO | Illuminated pushbutton |
Electrical connection values
Connecting cable | |
Ethernet | Ethernet/IP cable, at least cat. 5e |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
maximum feed-in current in the connection block | |
X1, X2 | max. 4000 mA |
Safety class | III |
Current consumption | max. 500 mA |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Power supply X1 | |
Fuse | |
external | min. 1 A slow blow |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Mechanical values and environment
Connection type | |
M12 Power, A-coded (X1) | |
Ethernet/IP cable, at least cat. 5e | M12, D-coded, screened (X4) |
Ethernet/IP cable, at least cat. 5e | M12, D-coded, screened (X3) |
M12 Power, A-coded (X2) | |
Installation orientation | Door hinge DIN right |
Switching frequency | 0.25 Hz |
Mechanical life | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
1 x 10⁶ | |
Response time | |
Guard locking | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Door position | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Bolt position | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP54 |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Control of guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.91 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.) |
Monitoring of guard locking and the guard position | |
Diagnostic Coverage (DC) | 99 % |
Category | 4 |
Performance Level | PL e |
PFHD | 3.37 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.) |
Miscellaneous
Product version number | V1.5 |
Additional feature | |
incl. lens set, ID no. 120377 | |
incl. lens set, ID no. 120344 |
Interface
Bus data protocol | Ethernet/IP |
Safety data protocol | CIP Safety |
Date interface | |
Ethernet |
Components
111838
MGB-H-AA1A6-R-111838
Handle module MGB-H... with automatically extending lockout mechanism
MGB-H-AA1A6-R-111838
Handle module MGB-H... with automatically extending lockout mechanism
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle
- Mounting plate
128331
MGB-L1B-EIA-R-128331
Locking module MGB-L1...-EI (guard locking by spring force) with 3 pushbuttons
MGB-L1B-EIA-R-128331
Locking module MGB-L1...-EI (guard locking by spring force) with 3 pushbuttons
- Guard locking with guard lock monitoring
- 3 illuminated pushbuttons
- Connection via M12 plug
- Pre-assembled on mounting plates
- Unicode
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2123624
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001506
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Safety Systems MGB-L..B-EI-… (Ethernet/IP) and With Data Structure Type A From V1.5.0
Doc. no.
Version
Language
Size
Operating Instructions Safety Systems MGB-L..B-EI-… (Ethernet/IP) and With Data Structure Type A From V1.5.0
Doc. no.
2126330
Version
09/21
Language
Size
2,9 MB
Manual de instrucciones Sistemas de seguridad MGB-L..B-EI-… (Ethernet/IP) y con estructura de datos de tipo A V1.5.0 o superior
Doc. no.
2126330
Version
09/21
Language
Size
3,0 MB
Betriebsanleitung Sicherheitssysteme MGB-L..B-EI-… (Ethernet/IP) und mit Datenstruktur Typ A ab V1.5.0
Doc. no.
2126330
Version
09/21
Language
Size
2,9 MB
사용 설명서 안전 시스템 MGB-L..B-EI-…(이더넷/IP) 데이터 구조 타입 A 포함 V1.5.0부터
Doc. no.
2126330
Version
09/21
Language
Size
3,3 MB
Instrucțiuni de utilizare Sisteme de siguranță MGB-L..B-EI-… (Ethernet/IP) și cu structură de date tip A începând de la versiunea V1.5.0
Doc. no.
2126330
Version
09/21
Language
Size
3,1 MB
Other Documents
Approvals and certificates
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
0,7 MB
Ordering data
Ordernumber | 128332 |
Item designation | MGB-L1HB-EIA-R-128332 |
Gross weight | 5,78kg |
Customs tariff number | 85371098 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |