Interlocking module MGB-L0...-EI with 2 pushbuttons, emergency stop
- Interlocking (without guard locking)
- Emergency stop according to ISO 13850, illuminated
- 2 illuminated pushbuttons
- including adhesive labels
- Connection via M12 plug
- Pre-assembled on mounting plates
- Unicode
Description
Dimensional drawings
Connection examples
Technical data
Approvals
Workspace
Secured switch-off distance sar | |
Door position | max. 65 mm |
Operating and display elements
Occupancy diagram | |
B0 | |
L1 |
Item | Color | Extras | Switching element | Slide-in label | Note slide-in label | Version | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
1 | with adhesive ring | 2 PD | Emergency stop illuminated | ||||||
2 | 1NO | Illuminated pushbutton | |||||||
3 | 1NO | Illuminated pushbutton |
Electrical connection values
Connecting cable | |
Ethernet | Ethernet/IP cable, at least cat. 5e |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
maximum feed-in current in the connection block | |
X1, X2 | max. 4000 mA |
Safety class | III |
Current consumption | max. 500 mA |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Power supply X1 | |
Fuse | |
external | min. 1 A slow blow |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Mechanical values and environment
Connection type | |
Ethernet/IP cable, at least cat. 5e | M12, D-coded, screened (X3) |
Ethernet/IP cable, at least cat. 5e | M12, D-coded, screened (X4) |
M12 Power, A-coded (X1) | |
M12 Power, A-coded (X2) | |
Installation orientation | Door hinge DIN left |
Switching frequency | 0.25 Hz |
Mechanical life | |
1 x 10⁶ | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
Response time | |
Emergency stop / machine stop | max. 100 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Bolt position | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Door position | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP54 |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Emergency stop | |
B10D | |
Emergency stop | 0.13 x 10⁶ |
Emergency-stop evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.05 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.) |
Monitoring of the guard position | |
Diagnostic Coverage (DC) | 99 % |
Category | 4 |
Performance Level | PL e |
PFHD | 3.37 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.) |
Miscellaneous
Slide-in label | |||||||
| |||||||
Product version number | V1.5 | ||||||
Additional feature | incl. lens set, ID no. 120344 |
Interface
Bus data protocol | Ethernet/IP |
Safety data protocol | CIP Safety |
Date interface | |
Ethernet |
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2123624
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001506
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Safety Systems MGB-L..B-EI-… (Ethernet/IP) and With Data Structure Type A From V1.5.0
Doc. no.
Version
Language
Size
Operating Instructions Safety Systems MGB-L..B-EI-… (Ethernet/IP) and With Data Structure Type A From V1.5.0
Doc. no.
2126330
Version
09/21
Language
Size
2,9 MB
Manual de instrucciones Sistemas de seguridad MGB-L..B-EI-… (Ethernet/IP) y con estructura de datos de tipo A V1.5.0 o superior
Doc. no.
2126330
Version
09/21
Language
Size
3,0 MB
Betriebsanleitung Sicherheitssysteme MGB-L..B-EI-… (Ethernet/IP) und mit Datenstruktur Typ A ab V1.5.0
Doc. no.
2126330
Version
09/21
Language
Size
2,9 MB
사용 설명서 안전 시스템 MGB-L..B-EI-…(이더넷/IP) 데이터 구조 타입 A 포함 V1.5.0부터
Doc. no.
2126330
Version
09/21
Language
Size
3,3 MB
Instrucțiuni de utilizare Sisteme de siguranță MGB-L..B-EI-… (Ethernet/IP) și cu structură de date tip A începând de la versiunea V1.5.0
Doc. no.
2126330
Version
09/21
Language
Size
3,1 MB
Other Documents
Application examples
Approvals and certificates
ODVA
Doc. no.
Version
Language
Size
ODVA
Doc. no.
Version
Language
Size
0,2 MB
TUEV Süd München M6A Zertifikat
Doc. no.
Version
Language
Size
TUEV Süd München M6A Zertifikat
Doc. no.
Version
Language
Size
0,3 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
0,7 MB
Ordering data
Ordernumber | 136557 |
Item designation | MGB-L0B-EIA-L-136557 |
Gross weight | 3,414kg |
European Article Number (EAN) | 4047048007048 |
Customs tariff number | 85371098 |
ECLASS | 27-27-24-03 Safety-related transponder switch |