EUCHNER – More than safety.
EUCHNER – More than safety.

CTP-L1-AP-U-HA-AZ-SA-EX-136675 (Order no. 136675)

Transponder-coded safety switch CTP-AP, M12, ATEX

  • ATEX version
  • Suitable for use in zones 2 and 22 (gases and dusts)
  • Safety switch with guard locking and integrated evaluation electronics
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With plug connector M12
  • Unicode
  • Door monitoring output OD
  • Guard lock monitoring output OL
  • Approach directions A, B and C (delivery state)
CTP-L1-AP-U-HA-AZ-SA-EX-136675 (Order no. 136675)

Description

Approach direction

Horizontal

Can be adjusted in 90° steps

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.

Guard locking type

CTP‑L1

Guard locking actuated by spring force and power-ON released (closed-circuit current principle).

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1IMPOperating voltage of guard locking solenoid, 24 V DCWH
2UBOperating voltage of AP electronics, 24 V DCBN
3FO1ASafety output, channel 1GN
4FO1BSafety output, channel 2YE
5OLGuard lock monitoring outputGY
6ODDoor monitoring outputPK
70 V UBAP electronics operating voltage, 0 VBU
8IMMGuard locking solenoid operating voltage, 0 VRD
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
CTP at a glance

Dimensional drawings

Dimensional drawings
1Auxiliary release
2Locking screw
3LEDs
4Protective plate
5Grounding terminal - for preventing electrostatic charging. Ground switch via cable. Cable cross-section 4...6 mm²

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/11FCC_2AJ58-05_

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection values

Fuse
external (operating voltage UB) 0.25 ... 8 A
external (solenoid operating voltage IMP) 0.5 ... 8 A
Power consumption 6 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Switching load
according to UL 24V DC, Class 2 (alternatively, see operating instructions)
Safety class III
Current consumption
IIMP 400 mA
IUB 40 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval min. 100 ms
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OD, OL
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Switching current 1 ... 50 mA
Safety outputs FO1A / FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Discrepancy time
both safety outputs max. 10 ms Acc. to EN IEC 60947-5-3
Turn-on time max. 400 ms
Off-state current Ir max. 0.25 mA
Switching current
per safety output FO1A / FO1B 1 ... 150 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 1 plug connector M12, 8-pin
Extraction force 20 N
Ready delay max. 1 s
Actuating force 10 N
Installation orientation any
Switching frequency max. 0.5 Hz
Mechanical life 1 x 10⁶
Overtravel 5 mm
Retention force 20 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65/IP66 (screwed tight plug connector/mating component)
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Safety switch housing Reinforced thermoplastic
Switch head cover Die-cast zinc
Locking force Fmax 3900 N
Locking force FZh 3000 N (Fzh = Fmax/1.3, depending on the actuator used)
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of guard lockingPL e-4.1x10-9420 y


PLMaximum SILCategoryMission time
Control of guard lockingDepending on external control of guard locking20 y


Miscellaneous

Explosion protection II3G Ex ec IIC T4 Gc X / II3D Ex tc IIIC T110°C Dc X
The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 5,5 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 136675
Item designation CTP-L1-AP-U-HA-AZ-SA-EX-136675
Gross weight 0,99kg
Customs tariff number 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.