EUCHNER – More than safety.
EUCHNER – More than safety.

MGB2-L2HB-PN-U-S3-DA-L-156391 (Order no. 156391)

Complete set MGB2-L2...-PN (2 pushbuttons, emergency stop, open-circuit current principle, door hinge on left)

  • Guard locking with guard lock monitoring
  • Illuminated emergency stop according to ISO 13850
  • 2 illuminated pushbuttons
  • 3 slide-in labels
  • Connection via plug connector RJ45, AIDA compliant
  • Integrated switch
  • Adjustable door hinge; factory setting: left
  • Unicode
MGB2-L2HB-PN-U-S3-DA-L-156391 (Order no. 156391)

Description

Guard locking type

MGB2-L2...

Guard locking by solenoid force. Activation of the guard locking by applying voltage to the guard locking solenoid. (open-circuit current principle)

PROFINET interface

Plug connector RJ45 (push-pull plug according to IEC 61076-3-117, variant 14)

PROFINET switch

Linear topology network structure due to integrated switch (supports MRP).

Flexible use as interlocking or guard locking

By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring).

Lens set

The color of the pushbuttons can be selected using the lens set 120344 included (5 colors).

Slide-in labels

The user can produce custom labeling using the enclosed slide-in labels. (3 pcs., blank)

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing
MGB2 Modular: at a glance
Multifunctional door locking systems

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Technical data

Approvals

FCC_2AJ58-02_

Bus modules MBM-PN-S3-MLI-3B-156310 (Order no. 156310)

Bus modules MBM-PN-S3-MLI-3B-156310  (Order no. 156310)

Electrical connection values

Connecting cable
MLI 5-pin, M12x1
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements EMC Directive 2014/30/EU
maximum feed-in current in the connection block
XD1, XD2 max. 16000 mA
Safety class III
Current consumption max. 150 mA
Degree of contamination (external, according to EN 60947-1) 3
Power supply XD1, XD2
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +15% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +15% (The auxiliary voltage is not required for the MGB system)

Mechanical values and environment

Connection type
Push-pull power (XD2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (XF2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (XF1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
Push-pull power (XD1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
Installation orientation any
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (Only in closed state with correctly mounted caps and the connecting cables or the connected modules)
Ambient temperature
with UB = 24 V DC -25 ... +55 °C
Material
Housing Fiber glass reinforced plastic, die-cast zinc, nickel plated
ML1C / ML2C
Connection type Screw terminal
Connection type Male plug
Type specification M12 EN 61076-2-101 / A-coded
Number of pins 5
Insertion cycles 100
ML1D
Connection type Connector (unlocked)
Connection type Male plug
Number of pins 5
Insertion cycles 100

Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)
Date interface
Ethernet

Locking modules MGB2-L2-MLI-U-YB1A1-DA-L-156381 (Order no. 156381)

Locking modules MGB2-L2-MLI-U-YB1A1-DA-L-156381  (Order no. 156381)

Mechanical values and environment

Installation orientation Door hinge DIN left

Handle modules MGB2-H-BA1A3-L-156394 (Order no. 156394)

Handle modules MGB2-H-BA1A3-L-156394  (Order no. 156394)

Mechanical values and environment

Installation orientation Door hinge DIN left
Degree of protection IP65
Ambient temperature -30 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Miscellaneous

Additional feature with automatic lockout mechanism

Submodules MSM-1-N-AA-QQQ-B1-137610

Submodules MSM-1-N-AA-QQQ-B1-137610

Operating and display elements

ItemColorExtrasVersionSwitching elementSlide-in labelNote slide-in labelNumberDesignation1LED
1Position for slide-in label
2Position for slide-in label
3Position for slide-in label

Mechanical values and environment

Installation orientation any
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Ambient temperature
with UB = 24 V DC -30 ... +55 °C
Material Fiber glass reinforced plastic

Miscellaneous

Slide-in label
NumberLabelingNote
3without marking
Additional feature Incl. label holder, ID no. 156732

Submodules MSM-1-P-CA-BPP-A1-136687

Submodules MSM-1-P-CA-BPP-A1-136687

Operating and display elements

ItemColorExtrasNote slide-in labelSlide-in labelVersionSwitching elementNumberDesignation1LED
1Illuminated emergency stop2 PD
2Illuminated pushbutton1NO
3Illuminated pushbutton1NO

Electrical connection values

Current consumption max. 32 mA
Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage 24 V
Switching current 5 ... 10 mA
LED power supply 24 V DC
Illuminated emergency stop
Breaking capacity max. 0.25 W
Switching voltage 5 ... 24 V
Switching current 1 ... 100 mA
LED power supply 24 V DC

Mechanical values and environment

Installation orientation any
Response time See operating instructions for bus module MBM-... or interlocking/locking module MGB2-I.-BR-... / MGB2-L.-BR-...
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (IP20) (IP65: only in the screwed tight state with the specified base units.)
Ambient temperature
with UB = 24 V DC -25 ... +55 °C
Material Fiber glass reinforced plastic

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Emergency stop0.13x10620 y


Miscellaneous

Software ID (SW ID) 136687
Additional feature incl. lens set, ID no. 120344

Connection accessories AC-MC-SB-M-A-157024

Connection accessories AC-MC-SB-M-A-157024

Electrical connection values

Connecting cable
MLI 5-pin, M12x1
Rated voltage 36 V
Rated voltage 30 V
Nominal current
at 40 °C 4 A
Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Ambient temperature -30 ... +55 °C
Connection 1
Connection type 2x M4 screws
Connection type Male plug
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic
Connection 2
Connection type Screw terminal
Connection type Male plug
Type specification M12 EN 61076-2-101 / A-coded
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic, die-cast zinc, nickel plated
Plug lock die-cast zinc, nickel plated

Modules MGB2-L2-MLI-U-Y0000-BJ-156392

Modules MGB2-L2-MLI-U-Y0000-BJ-156392
h3>Electrical connection values
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements EMC Directive 2014/30/EU
Safety class III
Current consumption max. 350 mA
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Switching frequency 0.25 Hz
Mechanical life
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
1 x 10⁶
Response time See operating instructions for bus module MBM-...
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (This is the case only in the closed state with correctly mounted connecting cables and submodules.)
Ambient temperature
with UB = 24 V DC -30 ... +55 °C
Material
Housing Fiber glass reinforced plastic, die-cast zinc, nickel plated
Locking force FZh 2000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Control of guard lockingPL e32.62x10-9420 y
Monitoring of the guard positionPL e32.62x10-9420 y
Monitoring of guard lockingPL e32.62x10-9420 y
Evaluating safety signalsPL e32.62x10-9420 y
Applies to all safety functions contained in submodules such as EMERGENCY STOP, enabling switch, etc.


Connection accessories AC-MC-00-0-B-156718

Connection accessories AC-MC-00-0-B-156718

Electrical connection values

Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Ambient temperature -30 ... +55 °C
Material Fiber glass reinforced plastic
Connection 1
Connection type 2x M4 screws
Degree of protection IP65 (Only in the screwed tight state with the specified base units.)

Miscellaneous

Color black
Additional feature
incl. fixing screws
incl. seal

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 53,1 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 156391
Item designation MGB2-L2HB-PN-U-S3-DA-L-156391
Gross weight 3,87kg
Customs tariff number 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.