EUCHNER – More than safety.
EUCHNER – More than safety.

MGB2-L1-MLI-M-Y0000-BJ-158698 (Order no. 158698)

Locking module MGB2-L1-MLI... (module without blanking covers, closed-circuit current principle)

  • Guard locking for the protection of persons or processes
  • Locking module MGB2 for connection to a bus module MBM
  • Interlocking with monitored guard locking
  • Category 4/PL e for the evaluation of all safety functions
  • Open version (without blanking covers)
  • Adjustable door hinge
  • Multicode
  • Compatible with all Modular devices
MGB2-L1-MLI-M-Y0000-BJ-158698 (Order no. 158698)

Description

Guard locking type

MGB2-L1...

Guard locking by spring force. Release by applying voltage to the guard locking solenoid. (closed-circuit current principle)

Door hinge

On the locking modules, the door stop can be changed from right to left and vice versa at any time with little effort.

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing
MGB2 Modular: at a glance
Multifunctional door locking systems

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Technical data

Approvals

c_UL_us_E155795_3/9TÜV Süd München_Z10 040393 0028 Rev.04EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-02_

Electrical connection values

Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements EMC Directive 2014/30/EU
Safety class III
Current consumption max. 350 mA
Transponder coding Multicode
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Switching frequency 0.25 Hz
Mechanical life
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
1 x 10⁶
Response time See operating instructions for bus module MBM-...
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (This is the case only in the closed state with correctly mounted connecting cables and submodules.)
Ambient temperature
with UB = 24 V DC -30 ... +55 °C
Material
Housing Fiber glass reinforced plastic, die-cast zinc, nickel plated
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Control of guard lockingPL e32.62x10-9420 y
Monitoring of the guard positionPL e32.62x10-9420 y
Monitoring of guard lockingPL e32.62x10-9420 y
Evaluating safety signalsPL e32.62x10-9420 y
Applies to all safety functions contained in submodules such as EMERGENCY STOP, enabling switch, etc.


Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 26,2 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 158698
Item designation MGB2-L1-MLI-M-Y0000-BJ-158698
Gross weight 1,22kg
Customs tariff number 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.