CMS-R-BZD-05V (Order no. 159518)

Read heads CMS, design B - with NO contact combinations, PVC

  • In combination with evaluation units ESM-BA...
  • Cube-shaped version, 36 x 26 mm
  • Connecting cable
  • Cable type: PVC
CMS-R-BZD-05V (Order no. 159518)

Description

Alignment of read head and actuator

Operating diagram, design B

CMS-R-BXO

<p>CMS-R-BXO</p>
  • typ. operating distance
  • typ. release distance
Dimension drawing
Dimension drawing
Circuit diagram CMS-R-BZD… (not actuated)
Circuit diagram CMS-R-BZD… (not actuated)

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_5/1

Workspace

Operating distance off
Monitoring contact max. 20 mm
Operating distance on
Monitoring contact min. 6 mm

Electrical connection values

Fuse
Power supply / safety contacts, external contact protection Fuse 10 A gG (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
rated conditional short-circuit current 100 A (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
Electrical switching frequency
At nominal current 8 A max. 0.1 Hz (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
at I_min = 10 mA max. 5 Hz (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
Switching voltage
DC 24 ... 35 V
Monitoring contact DC max. 35 V
Switching voltage according to UL
according to UL Class 2 max. 24 V AC/DC
Switching current
Monitoring contact max. 100 mA
max. 100 mA
Switching characteristics parallel
Switching delay from state change max. 26 ms (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3. Corresponds to the risk time according to EN 60947-5-3. This is the maximum OFF time for the safety outputs following removal of the actuator)

Mechanical values and environment

Connection type Hard-wired encapsulated cable with cable end sleeves 0.25 mm2
Number of NO contacts 2 NO contacts with internal fuse, 100 mA each, 1 NO contact as monitoring contact
Tightening torque 0.4 ... 0.5 Nm
Design B
Installation orientation any
Cable length 5 m
Mechanical life 100 x 10⁶
Degree of protection IP67
Ambient temperature -20 ... +80 °C
Material
Cable material PVC
Housing Fiber glass reinforced PPS
Method of operation magnetic, reed contact

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Monitoring of the guard position
B10D 20 x 10⁶

Miscellaneous

in compliance with EN ISO 13849-1: 2015; EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015; EN ISO 14119: 2013; EN 60947-5-3: 2013

In combination with read head ESM-BA201, ESM-BA202, ESM-BA203, ESM-BA301, ESM-BA302, ESM-BA303, ESM-BA201P, ESM-BA301P and actuator CMS-M-BH

Secured switch-off distance sar
with center offset m=0 max. 20 mm (The assured release distance s_ar corresponds to the reset distance.)
Secured switching distance sao
with center offset m=0 min. 7 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
Center offset
at s = 3 mm read distance 2.5 (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 3,8 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 159518
Item designation CMS-R-BZD-05V
Gross weight 0,264kg
Customs tariff number 85389099990
ECLASS 27-27-24-02 Safety-related magnetic proximity switch