EUCHNER – More than safety.
EUCHNER – More than safety.

MSM-1-R-CA-BPM-D2-160626 (Order no. 160626)

Submodule MSM-1-R... (emergency stop illuminated, 1 illuminated pushbutton, M12 plug connector for enabling switch)

  • Function expansion for modules MGB2 and MCM
  • Connection type: R
  • 1 illuminated emergency stop according to ISO 13850
  • 1 illuminated blue pushbutton
  • 1 plug connector M12 for connecting an enabling switch
MSM-1-R-CA-BPM-D2-160626 (Order no. 160626)

Description

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing
Wiring diagram for connection to MGB2 Classic
Wiring diagram for connection to MGB2 Classic
MGB2 Modular: at a glance
Multifunctional door locking systems

Dimensional drawings

Dimensional drawings
Pos 1Emergency stop according to ISO 13850
Pos 2Illuminated pushbutton
Pos 3M12 plug connector for connecting an enabling switch
Zmarks orientation of item 1

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Technical data

Operating and display elements

ItemColorExtrasSwitching elementVersionSlide-in labelNote slide-in labelNumberDesignation1LED
12 PDIlluminated emergency stop
2Blue1NOIlluminated pushbutton
3Connection M12x1 for enabling switch

Electrical connection values

Current consumption max. 38 mA
Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage 24 V
Switching current 5 ... 10 mA
LED power supply 24 V DC
Illuminated emergency stop
Breaking capacity max. 0.25 W
Switching voltage 5 ... 24 V
Switching current 1 ... 100 mA
LED power supply 24 V DC

Mechanical values and environment

Installation orientation any
Response time See operating instructions for bus module MBM-... or interlocking/locking module MGB2-I.-BR-... / MGB2-L.-BR-...
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (IP20) (When installed)
Ambient temperature
with UB = 24 V DC -25 ... +55 °C
Material Fiber glass reinforced plastic, die-cast zinc, nickel plated

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Evaluating safety signalsPL e-9.06x10-10420 y
Gilt nur für extern angeschlossene Sicherheitsfunktionen wie Zustimmtaster, Sicherheitsschalter usw.


B10DMission time
Emergency stop0.13x10620 y


Miscellaneous

Software ID (SW ID) 9000005

Ordering data

Ordernumber 160626
Item designation MSM-1-R-CA-BPM-D2-160626
Gross weight 0,125kg
Customs tariff number 85371098
ECLASS 27-24-26-05 Field bus, decentralized peripheral - function-/technology module

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.