Locking module MGB2-L2-BR... (module with blanking cover, open-circuit current principle, door hinge on right)
- Guard locking with guard lock monitoring
- Version with blanking cover
- 3 adhesive labels
- Cable entry M20 x 1.5 (order cable gland separately)
- Connection for signal light/enabling switch
- Adjustable door hinge; factory setting: right
- Unicode
Description
Guard locking type
MGB2-L2... | Guard locking by solenoid force. Activation of the guard locking by applying voltage to the guard locking solenoid. (open-circuit current principle) |
Flexible adaptation through configuration
- The evaluation module can be configured with the aid of DIP switches. Depending on the setting, the evaluation module behaves like an MGB2-BP or an MGB2-BR device.
- In addition, guard lock monitoring can be switched on or off on devices with guard locking. When guard lock monitoring is switched on, the safe outputs are switched on if the guard is safely locked. When guard lock monitoring is switched off, the safe outputs are switched on if the guard is closed and the bolt tongue is inserted into the MGB2.
- Release monitoring can be activated when guard lock monitoring is switched on. This signals whether the auxiliary release or escape release was actuated.
- Factor reset permits resetting to the factory setting.
Door hinge
On the locking modules, the door stop can be changed from right to left and vice versa at any time with little effort.
Dimensional drawings
Dimensional drawings
Technical data
Approvals
Mechanical values and environment
Installation orientation | Door hinge DIN right |
Submodules MSM-1-N-AA-000-A4-126372 (Order no. 126372)
Mechanical values and environment
Installation orientation | any |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Ambient temperature | |
with UB = 24 V DC | -30 ... +55 °C |
Material | Fiber glass reinforced plastic |
Locking modules MGB2-L2-BR-U-X0000-BJ-158168 (Order no. 158168)
Electrical connection values
Connection cross section | |
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0.25 ... 1.5 mm² |
(rigid/flexible) | 0.25 ... 1.5 mm² ((AWG 23 ... AWG 16)) |
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0.25 ... 0.75 mm² |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Discrepancy time | |
between FO1A and FO1B | max. 10 ms |
Utilization category | |
DC-13 | 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Risk time according to EN 60947-5-3 | max. 50 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
Safety class | III |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring outputs OD, OT/C, OL, OI | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UB-2 ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths) |
Output current | max. 50 mA |
Safety outputs FO1A, FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-3,5 ... UB V DC (Value at a switching current of 150mA without taking into account the cable lengths) |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
per safety output FO1A / FO1B | 1 ... 150 mA |
Turn-on time | max. 80 ms |
Test pulse duration | max. 0.3 ms |
Test pulse interval | min. 100 ms |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... +20% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Current consumption | |
IUB | max. 80 mA (at 20.4 V including safety inputs FI1A and FI1B, no load on outputs) |
Power supply IMP, IMM | |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +20% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Current consumption | |
IIMP | max. 375 mA |
Test pulse duration | max. 5 ms |
Test pulse interval | min. 100 ms |
Mechanical values and environment
Connection type | Other connection option to X5 / X6 available |
Ready delay | 5 s |
Switching frequency | 0.25 Hz |
Mechanical life | |
1 x 10⁶ | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65 (This is the case only in the closed state with correctly mounted connecting cables, submodules and connection submodules.) |
Ambient temperature | |
with UB = 24 V DC | -25 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic; die-cast zinc, nickel plated |
Locking force FZh | 2000 N |
Guard locking principle | Open-circuit current principle |
Submodules MSM-C-K-BA-SBS-S0-160847 (Order no. 160847)
Mechanical values and environment
Connection type | Cable entries M20x1.5 |
Installation orientation | any |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65 (IP20) (IP65: only in the screwed tight state with the specified base units.) |
Ambient temperature | -25 ... +55 °C |
Material | Fiber glass reinforced plastic |
Miscellaneous
Slide-in label | |||||||
| |||||||
Additional feature | |||||||
Incl. label holder, ID no. 156733 | |||||||
incl. socket connector set, ID no. 136572 |
AC-MC-00-0-B-156718 (Order no. 156718)
Electrical connection values
Degree of contamination according to EN 60664-1 | 3 |
Mechanical values and environment
Ambient temperature | -30 ... +55 °C |
Material | Fiber glass reinforced plastic |
Connection 1 | |
Connection type | 2x M4 screws |
Degree of protection | IP65 (Only in the screwed tight state with the specified base units.) |
Miscellaneous
Color | black |
Additional feature | |
incl. seal | |
incl. fixing screws |
Components
126372
MSM-1-N-AA-000-A4-126372
Submodule MSM-1-N... (blanking cover)
MSM-1-N-AA-000-A4-126372
Submodule MSM-1-N... (blanking cover)
- Function expansion for modules MGB2 and MCM
- Connection type: N
- Blanking cover
158168
MGB2-L2-BR-U-X0000-BJ-158168
Locking module MGB2-L2-BR... (module without blanking covers, open-circuit current principle)
MGB2-L2-BR-U-X0000-BJ-158168
Locking module MGB2-L2-BR... (module without blanking covers, open-circuit current principle)
- Guard locking for the protection of persons or processes
- Locking module MGB2 for direct connection to a control system
- Configurable as interlocking or guard locking
- Category 4/PL e for the evaluation of all safety functions
- Open version (without blanking covers)
- Connection for signal light/enabling switch
- Adjustable door hinge
- Unicode
- Compatible with BR technology
160847
MSM-C-K-BA-SBS-S0-160847
Connection submodule MSM-C... (cable entry M20 x 1.5, incl. 3 adhesive labels)
MSM-C-K-BA-SBS-S0-160847
Connection submodule MSM-C... (cable entry M20 x 1.5, incl. 3 adhesive labels)
- Connection submodule for MGB2 Classic
- Cable entry M20 x 1.5 (order cable gland separately)
156718
AC-MC-00-0-B-156718
Cover for unused module connections
AC-MC-00-0-B-156718
Cover for unused module connections
- Cover for unused connections
- incl. fixing screws
- incl. seal
Accessories
Connection material
Function expansion
Lock for auxiliary release for safety switch CTP/CTA/TP/STP
084177
AE-K-A1-DULK1-84177
AE-K-A1-DULK1-84177
- Lock unique locking
- Key removable in “unlocked” and “locked” positions
086236
AE-K-A1-IULK1-86236
AE-K-A1-IULK1-86236
- Identical locking
- Key removable in “unlocked” and “locked” positions
109212
AE-K-A1-IUK2-109212
AE-K-A1-IUK2-109212
- Identical locking
- Key can be removed only in “unlocked” position
121917
AE-K-A1-ILK1-121917
AE-K-A1-ILK1-121917
- Identical locking
- Key removable in “locked” position
MGB2-H
Handle module MGB2-H... (door handle, with automatic lockout mechanism, door hinge on right)
136691
MGB2-H-BA1A3-R-136691
MGB2-H-BA1A3-R-136691
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle
- Adjustable door hinge; factory setting: right
157369
MGB2-H-BA1A6-R-157369
MGB2-H-BA1A6-R-157369
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle
- Mounting plate
- Adjustable door hinge; factory setting: right
MSM-C
Connection submodule MSM-C... (plug connector M23, incl. 3 slide-in labels)
160849
MSM-C-K-BA-SH0-S1-160849
MSM-C-K-BA-SH0-S1-160849
- Connection submodule for MGB2 Classic
- Plug connector M23 (19-pin)
164732
MSM-C-K-BA-SH0-S2-164732
MSM-C-K-BA-SH0-S2-164732
- Connection submodule for MGB2 Classic
- Plug connector M23 (19-pin)
164954
MSM-C-K-BA-SH0-S3-164954
MSM-C-K-BA-SH0-S3-164954
- Connection submodule for MGB2 Classic
- Plug connector M23 (19-pin)
165673
MSM-C-K-BA-SR-S7-165673
MSM-C-K-BA-SR-S7-165673
- Connection submodule for MGB2 Classic
- Plug connector M23 (17-pin)
169566
MSM-C-K-BA-SH-S5-169566
MSM-C-K-BA-SH-S5-169566
- Connection submodule for MGB2 Classic
- Plug connector M23 (19-pin)
171935
MSM-C-K-BA-SH-S6-171935
MSM-C-K-BA-SH-S6-171935
- Connection submodule for MGB2 Classic
- Plug connector M23 (19-pin)
167011
MSM-C-K-BA-SH0-S4-167011
MSM-C-K-BA-SH0-S4-167011
- Connection submodule for MGB2 Classic
- Plug connector M23 (19-pin)
MSM-K
MSM-P
Submodule MSM-1-P... (3 illuminated pushbuttons with symbol)
164660
MSM-1-P-CA-PPP-F9-164660
MSM-1-P-CA-PPP-F9-164660
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 3 illuminated pushbuttons with symbol
170572
MSM-1-P-CA-PPP-K3-170572
MSM-1-P-CA-PPP-K3-170572
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 3 illuminated pushbuttons with symbol
172041
MSM-1-P-CA-PPP-M2-172041
MSM-1-P-CA-PPP-M2-172041
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 3 illuminated pushbuttons with symbol
172054
MSM-1-P-CA-PPP-M3-172054
MSM-1-P-CA-PPP-M3-172054
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 3 illuminated pushbuttons with symbol
Submodule MSM-1-P... (emergency stop illuminated, 2 illuminated pushbuttons)
136687
MSM-1-P-CA-BPP-A1-136687
MSM-1-P-CA-BPP-A1-136687
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 1 illuminated emergency stop according to ISO 13850
- 2 illuminated pushbuttons
- incl. lens set
165201
MSM-1-P-CA-BPP-G8-165201
MSM-1-P-CA-BPP-G8-165201
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 1 illuminated emergency stop according to ISO 13850
- 2 illuminated pushbuttons
Submodule MSM-1-P... (emergency stop, 2 illuminated pushbutton)
165823
MSM-1-P-CA-APP-H3-165823
MSM-1-P-CA-APP-H3-165823
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 1 emergency stop according to ISO 13850
- 2 illuminated pushbuttons
163119
MSM-1-P-CA-APP-E3-163119
MSM-1-P-CA-APP-E3-163119
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 1 emergency stop according to ISO 13850
- 2 illuminated pushbuttons
- incl. lens set
166725
MSM-1-P-CA-APP-H7-166725
MSM-1-P-CA-APP-H7-166725
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 1 emergency stop according to ISO 13850
- 2 illuminated pushbuttons
Submodule MSM-1-P... (illuminated emergency stop with protective collar, 2 illuminated pushbuttons)
126381
MSM-1-P-CS-BPP-A5-126381
MSM-1-P-CS-BPP-A5-126381
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 1 illuminated emergency stop with protective collar according to ISO 13850
- 2 illuminated pushbuttons
- incl. lens set
164333
MSM-1-P-CS-BPP-F4-164333
MSM-1-P-CS-BPP-F4-164333
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 1 illuminated emergency stop with protective collar according to ISO 13850
- 2 illuminated pushbuttons with labeling
Submodule MSM-1-P... (illuminated emergency stop with protective collar, illuminated pushbutton, key-operated rotary switch, form V)
164819
MSM-1-P-CS-BPH-G3-164819
MSM-1-P-CS-BPH-G3-164819
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 1 illuminated emergency stop with protective collar according to ISO 13850
- 1 illuminated pushbuttons
- 1 key-operated rotary switch, form V
- incl. lens set
164821
MSM-1-P-CS-BPH-G4-164821
MSM-1-P-CS-BPH-G4-164821
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 1 illuminated emergency stop with protective collar according to ISO 13850
- 1 illuminated blue pushbutton
- 1 key-operated rotary switch, 1 x 40°, form V
Submodule MSM-1-P... (illuminated emergency stop)
159480
MSM-1-P-CA-B00-C8-159480
MSM-1-P-CA-B00-C8-159480
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 1 illuminated emergency stop according to ISO 13850
169462
MSM-1-P-TA-B00-J6-169462
MSM-1-P-TA-B00-J6-169462
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 1 illuminated emergency stop according to ISO 13850
- Use down to a temperature of -30°C
Submodule MSM-1-P... (illuminated emergency stop, 2 illuminated white pushbuttons with symbol)
163609
MSM-1-P-CA-BPP-E5-163609
MSM-1-P-CA-BPP-E5-163609
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 1 illuminated emergency stop according to ISO 13850
- 2 illuminated white pushbuttons with symbol
161589
MSM-1-P-CA-BPP-D5-161589
MSM-1-P-CA-BPP-D5-161589
- Function expansion for modules MGB2 and MCM
- Connection type: P
- 1 illuminated emergency stop according to ISO 13850
- 2 illuminated white pushbuttons with symbol
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Data sheets
Data sheet
Doc. no.
Version
Language
Size
Data sheet
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Doc. no.
Version
01
Language
Size
0,1 MB
Data sheet
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Doc. no.
Version
03
Language
Size
0,2 MB
Data sheet
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Doc. no.
Version
01
Language
Size
0,1 MB
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2500504
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001507
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Safety Systems MGB2-L1…-BR.-… / MGB2-L2…-BR.-… and MGB2-L1…-BP.-… / MGB2-L2…-BP.-…
Doc. no.
Version
Language
Size
Operating Instructions Safety Systems MGB2-L1…-BR.-… / MGB2-L2…-BR.-… and MGB2-L1…-BP.-… / MGB2-L2…-BP.-…
Doc. no.
2500233
Version
02/23
Language
Size
7,5 MB
Mode d’emploi Systèmes de sécurité MGB2-L1…-BR.-… / MGB2-L2…-BR.-… et MGB2-L1…-BP.-… / MGB2-L2…-BP.-…
Doc. no.
2500233
Version
02/23
Language
Size
7,5 MB
Betriebsanleitung Sicherheitssysteme MGB2-L1…-BR.-… / MGB2-L2…-BR.-… und MGB2-L1…-BP.-… / MGB2-L2…-BP.-…
Doc. no.
2500233
Version
02/23
Language
Size
7,5 MB
Návod k použití Bezpečnostní systémy MGB2-L1…-BR.-… / MGB2-L2…-BR.-… a MGB2-L1…-BP.-… / MGB2-L2…-BP.-…
Doc. no.
2500233
Version
02/23
Language
Size
7,8 MB
Other Documents
Application examples
Approvals and certificates
FCC
Doc. no.
Version
Language
Size
FCC
Doc. no.
Version
Language
Size
0,2 MB
TUEV Süd München
Doc. no.
Version
Language
Size
TUEV Süd München
Doc. no.
Version
Language
Size
0,4 MB
TUEV Süd München
Doc. no.
Version
Language
Size
0,3 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
0,7 MB
Ordering data
Ordernumber | 161766 |
Item designation | MGB2-L2-BR-U-XA4S0-OB-R-161766 |
Gross weight | 1,37kg |
Customs tariff number | 85365019000 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |