CES-I-BP-M-C07-SI-162813 (Order no. 162813)

Non-contact safety switches CES-I-BP-.-C07, M12

  • Safety switch with integrated evaluation electronics
  • Suitable for separate operation (no series connection)
  • Multicode
  • M12 plug connector, 5-pin (pin 5 not used)
  • Direct connection to IP67 field modules
  • 2 safety outputs (semiconductor outputs)
  • Short circuit monitoring
  • Category 4 / PL e according to EN ISO 13849-1
  • Three active faces
CES-I-BP-M-C07-SI-162813 (Order no. 162813)

Description

Installation position

Permissible installation position

Multicode evaluation

Every suitable actuator is detected by the switch.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Terminal assignment

PinDesignationFunction
1UBPower supply, DC 24 V
2FO1ASafety output, channel A
30 VGround, DC 0 V
4FO1BSafety output, channel B
5-n.c.

Notice

The caps for the mounting holes are included.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
CES-C07: Transponder-coded safety switch

Dimensional drawings

Dimensional drawings
1LEDs
2Active face
3With the installation orientation shown: cable outlet on left or right

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20TUEV Süd München_Z10 040393 0031 Rev. 02c_UL_us_E346349_1/1FCC_2AJ58-12_ECOLAB__

Workspace

Repeat accuracy R
according to EN 60947-5-2 <= 10

Electrical connection values

Fuse
external (operating voltage) 0.25 ... 8 A
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC
UB 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV
Turn-on time
Safety outputs max. 100 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 125 ms
Safety class III
Current consumption 40 mA
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OD/C
Output type p-switching, short circuit-proof
Output voltage UB-1.5 ... UB V DC
Switching current 1 ... 50 mA
Safety outputs FO1A / FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
Discrepancy time max. 10 ms
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.25 mA
Switching current 1 ... 150 mA
Test pulse duration 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval ca 100 ms

Mechanical values and environment

Dimensions 40 x 26.5 x 18
Connection type M12 plug connector, 5-pin
Tightening torque max. 0.8 Nm
Ready delay 1.3 s
Operating altitude max. 4 000 m
Installation orientation any
Switching frequency max. 1 Hz
Mounting distance
between switches min. 50 mm
Mounting type non-flush on metal
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65/IP67/IP69/IP69K
Ambient temperature
with UB = 24 V DC -25 ... +55 °C (+65 °C at IL = max. 10 mA per safety output)
Material
Housing Plastic, PBT-PC-GF30

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e36x10-10420 y


Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures
Additional feature Caps included

In combination with actuator CES-A-BTN-C07-156230

Switch-on distance
Installation position A + B 13 mm
Installation position C + D 7 mm
Secured switch-off distance sar
in x direction/installation position A + B max. 20 mm
in x direction/installation position C + D max. 17 mm
Secured switching distance sao
in x direction/installation position C min. 3 mm
in x direction/installation position B min. 9 mm
in x direction/installation position D min. 2 mm
in x direction/installation position A min. 10 mm

In combination with actuator CES-A-BDN-06-158210, CES-A-BTN-C07-156230

Switching hysteresis 1 ... 2 mm

In combination with actuator CES-A-BDN-06-158210

Switch-on distance
Installation position C 8 mm
Installation position B 11 mm
Installation position D 7 mm
Installation position A 16 mm
Secured switch-off distance sar
in x direction/installation position A max. 24 mm
in x direction/installation position C max. 21 mm
Secured switching distance sao
in x direction/installation position A min. 13 mm
in x direction/installation position C min. 6 mm

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 4,1 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 162813
Item designation CES-I-BP-M-C07-SI-162813
Gross weight 0,05kg
Customs tariff number 85365019000
ECLASS 27-27-24-03 Safety-related transponder switch

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.