EUCHNER – More than safety.
EUCHNER – More than safety.

MGBS-P-I-AP-U-R-ZZE-SBB-162926 (Order no. 162926)

MGBS-P-I-AP, emergency stop, 2 x M12

  • Interlocking module without guard locking (order handle module separately)
  • Adjustable door hinge; factory setting: right
  • Direct connection to decentralized peripheral systems (e.g. ET200pro)
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • Unicode
  • Emergency stop
MGBS-P-I-AP-U-R-ZZE-SBB-162926 (Order no. 162926)

Description

Door hinge

The door hinge can be changed.

Unicode evaluation

Each handle module is highly coded (unicode). The locking module detects only handle modules that have been taught-in. Additional handle modules can be taught-in. Only the last handle module taught-in is detected.

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

X 1.1UBElectronics operating voltage, 24 V DCBN
X 1.2FO1ASafety output, channel AWH
X 1.30VUBElectronics operating voltage, 0 V DCBU
X 1.4FO1BSafety output, channel BBK
X 1.5-n.c.GY
X 2.1S1.A1EMERGENCY STOP (channel A)BN
X 2.2S1.B1EMERGENCY STOP (channel B)WH
X 2.3-n.c.BU
X 2.4S1.A2EMERGENCY STOP (channel A)BK
X 2.5S1.B2EMERGENCY STOP (channel B)GY
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1LEDs
2EMERGENCY STOP
3Auxiliary release (no function)

Connection examples

Connection examples

Technical data

Approvals

c_UL_us_E155795_3/11FCC_2AJ58-05_

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Operating and display elements

ItemColorExtrasNote slide-in labelVersionSwitching elementSlide-in labelNumberDesignation1LED
1Emergency stop2 PD

Electrical connection values

Fuse
external (operating voltage UB) 0.25 ... 8 A
Power consumption 1 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Switching load
according to UL 24V DC, Class 2 (alternatively, see operating instructions)
Safety class III
Current consumption
IUB 40 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval min. 100 ms
Degree of contamination (external, according to EN 60947-1) 3
Emergency stop
Breaking capacity max. 0.25 W
Switching voltage 5 ... 24 V
Switching current 1 ... 100 mA
Safety outputs FO1A / FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
Discrepancy time
both safety outputs max. 10 ms Acc. to EN IEC 60947-5-3
Turn-on time max. 400 ms
Off-state current Ir max. 0.25 mA
Switching current
per safety output FO1A / FO1B 1 ... 150 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 2 plug connector M12, 5-pin
Extraction force 20 N
Ready delay max. 1 s
Actuating force 10 N
Installation orientation Door hinge DIN right
Switching frequency max. 0.5 Hz
Mechanical life 1 x 10⁶
Overtravel 5 mm
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (When inserted and secured)
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Safety switch housing Reinforced thermoplastic
Switch bracket Die-cast zinc

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e-4.1x10-9420 y


B10DMission time
Emergency stop0.13x10620 y


Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions
Detent mechanism Snap-in bolt

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 11,0 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 162926
Item designation MGBS-P-I-AP-U-R-ZZE-SBB-162926
Gross weight 1,8kg
Customs tariff number 85365019000
ECLASS 27-27-24-03 Safety-related transponder switch

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.