HomeProductsTransponder-coded safety switches with guard lockingCTMCTM-ASCTM-L2-AS1B-U-ZZ-SJ-P-163974
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Unicode
- Hygienic version
Description
Guard locking type
CTM- L2 | Open-circuit current principle: guard locking by control of AS-i output 0 and release by spring force. |
Control of the guard locking solenoid
The guard locking solenoid can be controlled via AS-Interface bus bit D0 or via the auxiliary power.
AS-Interface inputs
D0, D1 | Door monitoring |
D2, D3 | Guard lock monitoring |
Evaluation is performed via a safety monitor.
AS-Interface outputs
D0 | Guard locking |
LED function display
- The ASI LED indicates the state of the ASi bus.
- The LOCK LED indicates the state of the guard locking.
- The STATE/DIA LED indicates the state of the switch and possible errors.
Dimensional drawings
1 | LEDs |
2 | Active read head face |
Connection examples
View of plug side |
Connection examples
Technical data
Approvals
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Electrical connection values
ASI data out | D0 = Control of guard locking |
ASI address | 1 - 31 |
ASI operating current | 50 mA |
ASI data in | |
according to AS-i Safety at Work | D1 (Door position) |
according to AS-i Safety at Work | D3 (Guard locking) |
according to AS-i Safety at Work | D2 (Guard locking) |
according to AS-i Safety at Work | D0 (Door position) |
AS-Interface auxiliary voltage | 24 V -15 ... 10 % |
Auxiliary current AS-Interface | 650 mA |
AS-Interface protocol | ASi-3 |
AS-Interface slave type | ID-Code: B, EA-Code: 7 |
ASI voltage | 26.5 ... 30 ... 31.6 V |
EMC protection requirements | Acc. to EN 60947-5-3 |
Solenoid duty cycle | 100 % |
Switching load | DC 24V, UL Class 2 (alternatively, see operating instructions) |
Safety class | III |
Degree of contamination (external, according to EN 60947-1) | 3 |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | Plug connector M12, 4-pin |
Extraction force | 30 N |
Ready delay | 3 s |
Actuating force | 35 N |
Installation orientation | any |
Switching frequency | max. 0.25 Hz |
Mechanical life | 1 x 10⁶ |
Overtravel | 2 mm |
Retention force | 15 N |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65/IP67/IP69/IP69K (When inserted and secured) |
Ambient temperature | |
with UB = 24 V DC | -20 ... +60 °C |
Material | |
Seals | Fluorinated rubber (FKM) |
Safety switch housing | Reinforced thermoplastic |
Locking force Fmax | 1300 N |
Locking force FZh | 1000 N |
Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | 3 | 4.83x10-9 | 4 | 20 y |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2525461
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001477
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTM-L2-AS1B Unicode/Multicode
Doc. no.
Version
Language
Size
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTM-L2-AS1B Unicode/Multicode
Doc. no.
2539116
Version
04/24
Language
Size
1,5 MB
Mode d’emploi Interrupteur de sécurité à codage par transpondeur avec interverrouillage pour la protection du process CTM-L2-AS1B Uni-/multicode
Doc. no.
2539116
Version
04/24
Language
Size
1,5 MB
Manual de instrucciones Interruptor de seguridad codificado por transponder con bloqueo para la protección de procesos CTM-L2-AS1B Unicode/Multicode
Doc. no.
2539116
Version
04/24
Language
Size
1,5 MB
Betriebsanleitung Transpondercodierter Sicherheitsschalter mit Zuhaltung für den Prozessschutz CTM-L2-AS1B Uni-/Multicode
Doc. no.
2539116
Version
04/24
Language
Size
1,4 MB
Návod k použití Bezpečnostní spínač s kódovaným transpondérem a jištěním ochranného krytu pro ochranu procesů CTM-L2-AS1B Unicode/Multicode
Doc. no.
2539116
Version
04/24
Language
Size
2,0 MB
Other Documents
Approvals and certificates
Asi Zertifikat CTM
Doc. no.
Version
Language
Size
Asi Zertifikat CTM
Doc. no.
20001493
Version
Language
Size
0,6 MB
FCC
Doc. no.
Version
Language
Size
FCC
Doc. no.
Version
Language
Size
0,1 MB
ISED
Doc. no.
Version
Language
Size
ISED
Doc. no.
Version
Language
Size
1,2 MB
Sales documents
Communication du futur – industrie 4.0
Doc. no.
Version
Language
Size
Communication du futur – industrie 4.0
Doc. no.
159044
Version
08-03/23
Language
Size
4,7 MB
Future-proof Communication – Industry 4.0
Doc. no.
Version
Language
Size
Future-proof Communication – Industry 4.0
Doc. no.
159043
Version
08-03/23
Language
Size
5,8 MB
La comunicación del futuro: la industria 4.0
Doc. no.
Version
Language
Size
La comunicación del futuro: la industria 4.0
Doc. no.
159045
Version
08-03/23
Language
Size
5,8 MB
Zukunftsfähige Kommunikation – Industrie 4.0
Doc. no.
Version
Language
Size
Zukunftsfähige Kommunikation – Industrie 4.0
Doc. no.
159042
Version
08-03/23
Language
Size
5,8 MB
小型ながら大 きなメリット - ガードロック付きトランスポンダ ー・コーデッド安全スイッチ CTM
Doc. no.
Version
Language
Size
小型ながら大 きなメリット - ガードロック付きトランスポンダ ー・コーデッド安全スイッチ CTM
Doc. no.
166084
Version
03-07/21
Language
Size
4,7 MB
面向未来的通信 – 工业4.0
Doc. no.
Version
Language
Size
面向未来的通信 – 工业4.0
Doc. no.
164814
Version
06-05/21
Language
Size
6,2 MB
UQS document
Bescheinigung
Doc. no.
Version
Language
Size
Bescheinigung
Doc. no.
ECO20001482
Version
Language
Size
0,2 MB
Ordering data
Ordernumber | 163974 |
Item designation | CTM-L2-AS1B-U-ZZ-SJ-P-163974 |
Gross weight | 0,26kg |
Customs tariff number | 85365019000 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |