EUCHNER – More than safety.
EUCHNER – More than safety.

MGB2-L1-BR-U-XB7S0-DY-L-164397 (Order no. 164397)

Locking module MGB2-L1-BR... (2 pushbuttons, closed-circuit current principle, door hinge on left)

  • Guard locking with guard lock monitoring
  • 2 illuminated pushbuttons
  • 3 adhesive labels
  • Cable entry M20 x 1.5 (order cable gland separately)
  • Adjustable door hinge; factory setting: left
  • Unicode
MGB2-L1-BR-U-XB7S0-DY-L-164397 (Order no. 164397)

Description

Guard locking type

MGB2-L1...

Guard locking by spring force. Release by applying voltage to the guard locking solenoid. (closed-circuit current principle)

Flexible adaptation through configuration

  • The evaluation module can be configured with the aid of DIP switches. Depending on the setting, the evaluation module behaves like an MGB2-BP or an MGB2-BR device.
  • In addition, guard lock monitoring can be switched on or off on devices with guard locking. When guard lock monitoring is switched on, the safe outputs are switched on if the guard is safely locked. When guard lock monitoring is switched off, the safe outputs are switched on if the guard is closed and the bolt tongue is inserted into the MGB2.
  • Release monitoring can be activated when guard lock monitoring is switched on. This signals whether the auxiliary release or escape release was actuated.
  • Factor reset permits resetting to the factory setting.

Lens set

The color of the pushbuttons can be selected using the lens set 120344 included (5 colors).

Adhesive labels

The user can produce custom labeling using the enclosed adhesive labels. (3 pcs., blank)

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Technical data

Approvals

c_UL_us_E155795_3/9TUEV Süd München_Z10 040393 0029 Rev. 02EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-03_

Mechanical values and environment

Installation orientation Door hinge DIN left

Locking modules MGB2-L1-BR-U-X0000-BX-136774 (Order no. 136774)

Locking modules MGB2-L1-BR-U-X0000-BX-136774  (Order no. 136774)

Electrical connection values

Connection cross section
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 0.25 ... 0.75 mm²
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 0.25 ... 1.5 mm²
(rigid/flexible) 0.25 ... 1.5 mm² ((AWG 23 ... AWG 16))
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 1.5 kV
Discrepancy time
between FO1A and FO1B max. 10 ms
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Risk time according to EN 60947-5-3 max. 50 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 10 ms
Safety class III
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
Monitoring outputs OD, OT/C, OL, OI
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage UB-2 ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
Output current max. 50 mA
Safety outputs FO1A, FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
UFO1A /UFO1B LOW 0 ... 1 V DC
UFO1A /UFO1B HIGH UB-3,5 ... UB V DC (Value at a switching current of 150mA without taking into account the cable lengths)
Output current
per safety output FO1A / FO1B 1 ... 150 mA
Turn-on time max. 80 ms
Test pulse duration max. 0.3 ms
Test pulse interval min. 100 ms
Power supply UB
Operating voltage DC
UB 24 V DC -15% ... +20% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Current consumption
IUB max. 80 mA (at 20.4 V including safety inputs FI1A and FI1B, no load on outputs)
Power supply IMP, IMM
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +20% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Current consumption
IIMP max. 375 mA
Test pulse duration max. 5 ms
Test pulse interval min. 100 ms

Mechanical values and environment

Ready delay 5 s
Switching frequency 0.25 Hz
Mechanical life
1 x 10⁶
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (This is the case only in the closed state with correctly mounted connecting cables, submodules and connection submodules.)
Ambient temperature
with UB = 24 V DC -25 ... +55 °C
Material
Housing Fiber glass reinforced plastic; die-cast zinc, nickel plated
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Submodules MSM-1-P-CA-PP0-B7-137742 (Order no. 137742)

Submodules MSM-1-P-CA-PP0-B7-137742  (Order no. 137742)

Operating and display elements

ItemColorExtrasNote slide-in labelSlide-in labelSwitching elementVersionNumberDesignation1LED
11NOIlluminated pushbutton
21NOIlluminated pushbutton

Electrical connection values

Current consumption max. 20 mA
Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage 24 V
Switching current 5 ... 10 mA
LED power supply 24 V DC

Mechanical values and environment

Installation orientation any
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (IP20) (IP65: only in the screwed tight state with the specified base units.)
Ambient temperature
with UB = 24 V DC -25 ... +55 °C
Material Fiber glass reinforced plastic

Miscellaneous

Software ID (SW ID) 137742
Additional feature incl. lens set, ID no. 120344

Submodules MSM-C-K-BA-SBS-S0-160847 (Order no. 160847)

Submodules MSM-C-K-BA-SBS-S0-160847  (Order no. 160847)

Mechanical values and environment

Connection type Cable entries M20x1.5
Installation orientation any
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (IP20) (IP65: only in the screwed tight state with the specified base units.)
Ambient temperature -25 ... +55 °C
Material Fiber glass reinforced plastic

Miscellaneous

Slide-in label
NumberLabelingNote
3without marking
Additional feature
Incl. label holder, ID no. 156733
incl. socket connector set, ID no. 136572

AC-MC-00-0-B-156718 (Order no. 156718)

AC-MC-00-0-B-156718  (Order no. 156718)

Electrical connection values

Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Ambient temperature -30 ... +55 °C
Material Fiber glass reinforced plastic
Connection 1
Connection type 2x M4 screws
Degree of protection IP65 (Only in the screwed tight state with the specified base units.)

Miscellaneous

Color black
Additional feature
incl. seal
incl. fixing screws

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 21,8 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 164397
Item designation MGB2-L1-BR-U-XB7S0-DY-L-164397
Gross weight 1,4kg
Customs tariff number 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.