Transponder coded safety switch CTS-C1-BR with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Series connection possible
- Closed-circuit current principle
- Connecting cable , PVC, 25 cm, plug connector M12, 8-pin
- Monitoring outputs guard locking / door position 1
Description
Guard locking type
CTS-C1 | Guard locking actuated by spring force and power-ON released (closed-circuit current principle). |
FlexFunction
The actuator configures the switch on setup. Depending on the actuator selected, guard lock monitoring of the safety switch is active or inactive and evaluation of the actuator code takes place with a high or low coding level.
series connection
Safety switches in the CTS-...-BR version can be integrated into a BR device chain. Further information on series connection can be found in the operating instructions for the device.
Auxiliary release / escape release
- Auxiliary release on front and rear side
- Escape release can be retrofitted, on rear side
Connector assignment
Pin 5 assignment depending on the function actuator
Pin | A-FLX-D-0C-167919 | A-FLX-D-0D-169044 | A-FLX-D-0E-169045 | A-FLX-D-0F-169046 |
---|---|---|---|---|
L + HC | I + HC | L + LC | I + LC | |
5 | OD/C Door position 1 / Communication | OL/C Guard locking / communication | OD/C Door position 1 / Communication | OL/C Guard locking / communication |
Dimensional drawings
1 | Auxiliary release |
2 | LEDs |
Connection examples
Technical data
Approvals
Electrical connection values
Fuse | |
IMP | 1 ... 8 A external |
UB | 1 ... 8 A external |
Power consumption | 9 W |
rated conditional short-circuit current | 100 A |
Rated insulation voltage Ui | 32 V |
Rated impulse withstand voltage Uimp | 0.8 kV |
Operating voltage DC | |
UB | 24 V DC -15% ... +20% (reverse polarity protected, regulated, residual ripple<5%, SELV) |
Discrepancy time | max. 10 ms |
Turn-on time | max. 400 ms |
EMC protection requirements | Acc. to EN 60947-5-3 |
Solenoid operating voltage DC | 24 V DC -15% ... +20% reverse polarity protected, regulated, residual ripple<5%, SELV |
Solenoid duty cycle | 100 % |
Risk time according to EN 60947-5-3 | max. 200 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
Switching load | |
according to UL | DC 24 V, class 2 |
Safety class | |
EN IEC 61140 | III |
Current consumption | |
IUB | 50 mA |
IIMP | 500 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring outputs Ox/C | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8xUB ... UB V DC |
Output current | |
I-configuration (guard lock monitoring inactive) | 1 ... 10 mA |
L configuration (guard lock monitoring active) | 1 ... 20 mA |
Safety outputs FO1A/FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
UFO1A /UFO1B HIGH | UB-4V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths) |
Output current | |
L configuration (guard lock monitoring active) | 1 ... 80 mA |
I-configuration (guard lock monitoring inactive) | 1 ... 75 mA |
Utilization category | |
DC-13 I configuration (guard lock monitoring inactive) | 24 V 75 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads) |
DC-13 L configuration (guard lock monitoring active) | 24 V 80 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads) |
Test pulse duration | max. 0.3 ms |
Test pulse interval | min. 96 ms |
Mechanical values and environment
Approach speed | max. 20 m/min |
Extraction force | 25 N |
Ready delay | max. 5 s |
Actuating force | 25 N |
Installation orientation | any |
Mechanical life | 1 x 10⁶ |
Retention force | 10 N |
Shock and vibration resistance | Acc. to EN 60947-5-3 |
Degree of protection | IP65/IP67/IP69/IP69K |
Ambient temperature | -20 ... +55 °C (A maximum value of +50 °C applies in the I-configuration of the switch (guard lock monitoring inactive)) |
Material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Reinforced thermoplastic |
Connecting cable | PVC |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Guard locking principle | Closed-circuit current principle |
Connection X1 | |
Connection type | Connecting cable with plug connector M12 |
Static bending radius | 8x cable diameter |
Cable outlet | straight |
Cable length | 0.25 m |
Number of pins | 8 |
Safety outputs FO1A/FO1B | |
Switching frequency | max. 0.2 Hz |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | 3 | 6.44x10-9 | 4 | 20 y |
Monitoring of guard locking | PL e | 3 | 6.44x10-9 | 4 | 20 y |
Valid only with active guard lock monitoring (guard locking for personnel protection). Dependent on the actuator used. |
PL | Maximum SIL | Category | Mission time | |
---|---|---|---|---|
Control of guard locking | Depending on external control of guard locking | 20 y |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Accessories
A-FLX-D-0C-167919
- Function actuator for configuration of the safety switch CTS
- Configuration: monitoring of the guard locking, high coding level (L+HC)
A-FLX-D-0E-169045
- Function actuator for configuration of the safety switch CTS
- Configuration: monitoring of the guard locking, low coding level (L+LC)
A-FLX-D-0D-169044
- Function actuator for configuration of the safety switch CTS
- Configuration: monitoring of the door position, high coding level (I+HC)
A-FLX-D-0F-169046
- Function actuator for configuration of the safety switch CTS
- Configuration: monitoring of the door position, low coding level (I+LC)
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Leitungslängen Transpondercodierter Sicherheitsschalter CTS-C1-BR-…-.SA
Other Documents
Ordering data
Ordernumber | 174014 |
Item designation | CTS-C1-BR-CC-FLX-AP-VSA-174014 |
Gross weight | 0,555kg |
Customs tariff number | 85365019000 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |