BP/BR safety switch with guard locking
Benefits for you
- Communicating safety switch with guard locking and safe guard lock monitoring
- Industry 4.0 ready
- Safety category 4 and PL e according to EN ISO 13849-1
Industry 4.0 ready
Switches from system families BP and BR can communicate in combination with an EUCHNER IO-Link Gateway, and send process and device data to higher-level control systems. Comprehensive diagnostic messages enable rapid and targeted troubleshooting.Diagnostic information
The safety switches in this group can forward comprehensive diagnostic information to the control system. The devices supply process-relevant parameters in real time. They even provide information on preventive maintenance. The sensors measure relevant parameters in the surroundings to indicate problems before a machine failure can occur. In combination with the IO-Link Gateways GWY-CB and ESM-CB, this information is polled from every switch and provided to the control system via IO-Link.Products (42)
No results found
166702
CTA-L1-BP-U-HA-AP-SA-166702
Transponder-coded safety switch CTA-BP, M12
CTA-L1-BP-U-HA-AP-SA-166702
Transponder-coded safety switch CTA-BP, M12
- Safety switch with guard locking and integrated evaluation electronics
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Closed-circuit current principle
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)
165454
CTA-L1-BP-U-HA-AP-SII-165454
Transponder-coded safety switch CTA-BP, 2 x M12
CTA-L1-BP-U-HA-AP-SII-165454
Transponder-coded safety switch CTA-BP, 2 x M12
- Safety switch with guard locking and integrated evaluation electronics
- Direct connection to decentralized peripheral systems (e.g. ET200pro)
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Closed-circuit current principle
- Up to category 4 / PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)
170930
CTA-L1-BP-U-HA-AP-SII-170930
Transponder-coded safety switch CTA-BP, 2 x M12
CTA-L1-BP-U-HA-AP-SII-170930
Transponder-coded safety switch CTA-BP, 2 x M12
- Safety switch with guard locking and integrated evaluation electronics
- Direct connection to decentralized peripheral systems (e.g. ET200pro)
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Closed-circuit current principle
- Up to category 4 / PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)
166653
CTA-L1-BR-U-HA-AP-SAB-166653
Transponder-coded safety switch CTA-BR, 2 x M12
CTA-L1-BR-U-HA-AP-SAB-166653
Transponder-coded safety switch CTA-BR, 2 x M12
- Safety switch with guard locking and integrated evaluation electronics
- Up to 20 switches in series
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Closed-circuit current principle
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector 2 x M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)
166257
CTA-L1-BR-U-HA-AP-SH-166257
Transponder-coded safety switch CTA-BR, M23
CTA-L1-BR-U-HA-AP-SH-166257
Transponder-coded safety switch CTA-BR, M23
- Safety switch with guard locking and integrated evaluation electronics
- Series connection possible
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Closed-circuit current principle
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M23
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)
170659
CTA-L2-BP-U-HA-AP-SA-170659
Transponder-coded safety switch CTA-BP, M12
CTA-L2-BP-U-HA-AP-SA-170659
Transponder-coded safety switch CTA-BP, M12
- Safety switch with guard locking and integrated evaluation electronics
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Open-circuit current principle
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)
166701
CTA-L2-BR-U-HA-AP-SAB-166701
Transponder-coded safety switch CTA-BR, 2 x M12
CTA-L2-BR-U-HA-AP-SAB-166701
Transponder-coded safety switch CTA-BR, 2 x M12
- Safety switch with guard locking and integrated evaluation electronics
- Up to 20 switches in series
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Open-circuit current principle
- Up to category 4 / PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)
170491
CTM-C2-BP-HC-FLX-AZ-SA-170491
Transponder-coded safety switch CTM-C2-BP, M12
CTM-C2-BP-HC-FLX-AZ-SA-170491
Transponder-coded safety switch CTM-C2-BP, M12
- Guard locking suitable for process protection only
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- High coding level
- FlexFunction device
170490
CTM-CBI-BP-HC-FLX-AZ-SA-170490
Transponder-coded safety switch CTM-CBI-BP, M12
CTM-CBI-BP-HC-FLX-AZ-SA-170490
Transponder-coded safety switch CTM-CBI-BP, M12
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- High coding level
- FlexFunction device
174747
CTM-I2-BR-M-ZZ-SA-P-174747
Transponder-coded safety switch CTM-I2-BR, M12
CTM-I2-BR-M-ZZ-SA-P-174747
Transponder-coded safety switch CTM-I2-BR, M12
- Guard locking only suitable for process protection: The safety outputs are switched on when the door is closed.
- Series connection possible
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force 35/30/15 N
- Plug connector M12, 8-pin
- Multicode
- Hygienic version
168250
CTM-I2-BR-U-AZ-SA-168250
Transponder-coded safety switch CTM-I2-BR, M12
CTM-I2-BR-U-AZ-SA-168250
Transponder-coded safety switch CTM-I2-BR, M12
- Guard locking only suitable for process protection: The safety outputs are switched on when the door is closed.
- Series connection possible
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode
168251
CTM-I2-BR-U-AZ-SA-168251
Transponder-coded safety switch CTM-I2-BR, M12
CTM-I2-BR-U-AZ-SA-168251
Transponder-coded safety switch CTM-I2-BR, M12
- Guard locking only suitable for process protection: The safety outputs are switched on when the door is closed.
- Series connection possible
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode
166870
CTM-L2-BR-M-AZ-SA-166870
Transponder-coded safety switch CTM-L2-BR, M12
CTM-L2-BR-M-AZ-SA-166870
Transponder-coded safety switch CTM-L2-BR, M12
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Series connection possible
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Auxiliary release
- Multicode
167789
CTM-L2-BR-M-ZZ-SA-P-167789
Transponder-coded safety switch CTM-L2-BR, M12
CTM-L2-BR-M-ZZ-SA-P-167789
Transponder-coded safety switch CTM-L2-BR, M12
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Series connection possible
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Multicode
- Hygienic version
173223
CTM-L2-BR-M-ZZ-V15-P-173223
Transponder-coded safety switch CTM-L2-BR, connection cable, flying lead
CTM-L2-BR-M-ZZ-V15-P-173223
Transponder-coded safety switch CTM-L2-BR, connection cable, flying lead
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Series connection possible
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Connection cable, connecting cable, 15m, flying lead
- Multicode
- Hygienic version
168866
CTM-L2-BR-U-AZ-SA-168866
Transponder-coded safety switch CTM-L2-BR, M12
CTM-L2-BR-U-AZ-SA-168866
Transponder-coded safety switch CTM-L2-BR, M12
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Series connection possible
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode
166088
CTM-LBI-BP-M-AZ-SA-166088
Transponder-coded safety switch CTM-LBI-BP, M12
CTM-LBI-BP-M-AZ-SA-166088
Transponder-coded safety switch CTM-LBI-BP, M12
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Multicode
166090
CTM-LBI-BP-M-AZ-SA-166090
Transponder-coded safety switch CTM-LBI-BP, M12
CTM-LBI-BP-M-AZ-SA-166090
Transponder-coded safety switch CTM-LBI-BP, M12
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Multicode
166087
CTM-LBI-BP-U-AZ-SA-166087
Transponder-coded safety switch CTM-LBI-BP, M12
CTM-LBI-BP-U-AZ-SA-166087
Transponder-coded safety switch CTM-LBI-BP, M12
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode
166089
CTM-LBI-BP-U-AZ-SA-166089
Transponder-coded safety switch CTM-LBI-BP, M12
CTM-LBI-BP-U-AZ-SA-166089
Transponder-coded safety switch CTM-LBI-BP, M12
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode
165517
CTM-LBI-BR-M-AZ-SA-165517
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-M-AZ-SA-165517
Transponder-coded safety switch CTM-LBI-BR, M12
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Multicode
166588
CTM-LBI-BR-M-AZ-SA-166588
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-M-AZ-SA-166588
Transponder-coded safety switch CTM-LBI-BR, M12
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Auxiliary release
- Multicode
166092
CTM-LBI-BR-M-AZ-SP-166092
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-M-AZ-SP-166092
Transponder-coded safety switch CTM-LBI-BR, M12
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 12-pin
- Auxiliary release
- Multicode
168651
CTM-LBI-BR-M-ZZ-SA-P-168651
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
CTM-LBI-BR-M-ZZ-SA-P-168651
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Multicode
- Hygienic version
161638
CTM-LBI-BR-U-AZ-SA-161638
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-U-AZ-SA-161638
Transponder-coded safety switch CTM-LBI-BR, M12
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode
161639
CTM-LBI-BR-U-AZ-SA-161639
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-U-AZ-SA-161639
Transponder-coded safety switch CTM-LBI-BR, M12
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode
167795
CTM-LBI-BR-U-AZ-SA-167795
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-U-AZ-SA-167795
Transponder-coded safety switch CTM-LBI-BR, M12
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode
166091
CTM-LBI-BR-U-AZ-SP-166091
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-U-AZ-SP-166091
Transponder-coded safety switch CTM-LBI-BR, M12
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 12-pin
- Auxiliary release
- Unicode
161496
CTM-LBI-BR-U-ZZ-SA-P-161496
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
CTM-LBI-BR-U-ZZ-SA-P-161496
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Unicode
- Hygienic version
161640
CTM-LBI-BR-U-ZZ-SA-P-161640
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
CTM-LBI-BR-U-ZZ-SA-P-161640
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Unicode
- Hygienic version
172870
CTS-C1-BP-CC-FLX-AP-USA-172870
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
CTS-C1-BP-CC-FLX-AP-USA-172870
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Closed-circuit current principle
- Connection cable, connecting cable, PUR, 25 cm, plug connector(s) M12, 8-pin
- Monitoring outputs guard locking and door position 1
167917
CTS-C1-BP-CC-FLX-AP-VSA-167917
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
CTS-C1-BP-CC-FLX-AP-VSA-167917
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Closed-circuit current principle
- Connecting cable , PVC, 25 cm, plug connector M12, 8-pin
- Monitoring outputs guard locking and door position 1
169052
CTS-C1-BP-CC-FLX-AP-VSA-169052
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
CTS-C1-BP-CC-FLX-AP-VSA-169052
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Closed-circuit current principle
- Connecting cable , PVC, 25 cm, plug connector M12, 8-pin
- Monitoring outputs door position 1 / guard locking and escape release
171593
CTS-C1-BP-CC-FLX-AP-VSA-171593
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
CTS-C1-BP-CC-FLX-AP-VSA-171593
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Closed-circuit current principle
- Connecting cable , PVC, 25 cm, plug connector M12, 8-pin
- Monitoring outputs guard locking and door position 2
173374
CTS-C1-BR-CC-FLX-AP-UAB-173374
Transponder-coded safety switch CTS-C1-BR with FlexFunction, 2 x M12
CTS-C1-BR-CC-FLX-AP-UAB-173374
Transponder-coded safety switch CTS-C1-BR with FlexFunction, 2 x M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Up to 20 switches in series
- Closed-circuit current principle
- Connection cable, connecting cable, PUR, 25 cm, plug connector(s) 2 x M12
- Monitoring outputs door position 1 / guard locking
169053
CTS-C1-BR-CC-FLX-AP-V05-169053
Transponder-coded safety switch CTS-C1-BR with FlexFunction, connecting cable with flying lead
CTS-C1-BR-CC-FLX-AP-V05-169053
Transponder-coded safety switch CTS-C1-BR with FlexFunction, connecting cable with flying lead
- Up to category 4 / PL e according to EN ISO 13849-1
- Up to 20 switches in series
- Closed-circuit current principle
- Connecting cable, PVC, 5 m, flying lead
- Monitoring outputs guard locking and door position 1
169612
CTS-C1-BR-CC-FLX-AP-VAB-169612
Transponder-coded safety switch CTS-C1-BR with FlexFunction, 2 x M12
CTS-C1-BR-CC-FLX-AP-VAB-169612
Transponder-coded safety switch CTS-C1-BR with FlexFunction, 2 x M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Up to 20 switches in series
- Closed-circuit current principle
- Connecting cable, PVC, 25 cm, plug connector 2 x M12
- Monitoring outputs door position 1 / guard locking
174014
CTS-C1-BR-CC-FLX-AP-VSA-174014
Transponder coded safety switch CTS-C1-BR with FlexFunction, M12
CTS-C1-BR-CC-FLX-AP-VSA-174014
Transponder coded safety switch CTS-C1-BR with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Series connection possible
- Closed-circuit current principle
- Connecting cable , PVC, 25 cm, plug connector M12, 8-pin
- Monitoring outputs guard locking / door position 1
174157
CTS-C2-BP-CC-FLX-AP-USA-174157
Transponder-coded safety switch CTS-C2-BP with FlexFunction, M12
CTS-C2-BP-CC-FLX-AP-USA-174157
Transponder-coded safety switch CTS-C2-BP with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Guard locking suitable for process protection only
- Open-circuit current principle
- Connection cable, connecting cable, PUR, 25 cm, plug connector(s) M12, 8-pin
- Monitoring outputs guard locking and door position 1
169051
CTS-C2-BP-CC-FLX-AP-VSA-169051
Transponder-coded safety switch CTS-C2-BP with FlexFunction, M12
CTS-C2-BP-CC-FLX-AP-VSA-169051
Transponder-coded safety switch CTS-C2-BP with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Guard locking suitable for process protection only
- Open-circuit current principle
- Connecting cable , PVC, 25 cm, plug connector M12, 8-pin
- Monitoring outputs guard locking and door position 1
169613
CTS-C2-BR-CC-FLX-AP-VAB-169613
Transponder-coded safety switch CTS-C2-BR with FlexFunction, 2 x M12
CTS-C2-BR-CC-FLX-AP-VAB-169613
Transponder-coded safety switch CTS-C2-BR with FlexFunction, 2 x M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Guard locking suitable for process protection only
- Up to 20 switches in series
- Open-circuit current principle
- Connecting cable, PVC, 25 cm, plug connector 2 x M12
- Monitoring outputs door position 1 / guard locking
174018
CTS-C2-BR-CC-FLX-AP-VSA-174018
Transponder coded safety switch CTS-C2-BR with FlexFunction, M12
CTS-C2-BR-CC-FLX-AP-VSA-174018
Transponder coded safety switch CTS-C2-BR with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Guard locking suitable for process protection only
- Series connection possible
- Open-circuit current principle
- Connecting cable , PVC, 25 cm, plug connector M12, 8-pin
- Monitoring outputs guard locking / door position 1