EUCHNER – More than safety.
EUCHNER – More than safety.

TZ1LE024RC18VAB-C2123 (Order no. 097347)

Safety switch TZ, plug connector M23 (RC18), emergency unlocking with rotary knob, escape release with pushbutton, special wiring

  • Plug connector M23 (RC18)
  • Escape release with pushbutton
  • Emergency unlocking with rotary knob
  • LED indicator
  • Protective plate for switch head
  • Actuating head fitted left
  • Closed-circuit current principle
TZ1LE024RC18VAB-C2123 (Order no. 097347)

Description

Approach direction

Horizontal

Can be adjusted in 90° steps

Guard locking principle

closed-circuit current (power to unlock): In a safety guard with guard locking according to the closed-circuit current principle, the guard is locked by spring force until the guard locking solenoid is supplied with current. The guard is unlocked by means of magnetic force. This is also referred to as mechanical guard locking.

Protective plate for switch head

Makes tampering with the switch more difficult.

LED indicator

The switch has two freely assignable LED indicators (red and green).

Switching element

SK

2131

Slow-action switching contact

Contacts for door monitoring: 2 positively driven, positively driven contacts 1 NO contact

ÜK

3131

Slow-action switching contact

Contacts for guard locking: 2 positively driven, positively driven contacts 2 NO contacts

Escape release

This is used for manual release of guard locking from the danger zone without tools.

Emergency release

The emergency unlocking on the front is used to unlock the guard locking without tools in the event of danger. Unblocking and restoring readiness for operation requires an effort comparable to a repair. A sealing can be attached to prevent tampering.

Required accessories

Actuator is not included in the scope of delivery.

Switching function
Switching function
Dimension drawing
Dimension drawing
Wiring diagram SK:2131H/ÜK:3131HRC18-C1937
Wiring diagram SK:2131H/ÜK:3131HRC18-C1937
Electromechanical safety switches in use

Functional drawings

Functional drawings

Dimensional drawings

Dimensional drawings
1Emergency unlocking (rotary knob)
2Escape release (pushbutton)

Connection examples

Connection examples
Door monitoring
Solenoid monitoring

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20DNV-GL_TAA0000172 Rev. 1CCC2024010305643586_SafetySwitch T_STc_UL_us_E155795_2/4

Electrical connection values

Power consumption 10 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 1.5 kV
Utilization category
AC-15 4 A 50 V (>70 °C =>2 A)
DC-13 4 A 24 V (>70 °C =>2 A)
Short circuit protection according to IEC 60269-1 4A gG (> 70 °C => 2A gG)
Solenoid operating voltage
AC/DC 24 V -15% ... +10%
Solenoid duty cycle 100 %
Switching voltage
min. at 10 mA 12 V
Switching current
min. at 24 V 1 mA
thermal rated current Ith 4 A (>70 °C =>2 A)

Mechanical values and environment

Approach speed max. 20 m/min
Approach direction
Actuating head left C
Connection type
1 x Plug connector RC18 (18 + PE)
Number of door position NO contacts 1
Number of guard lock monitoring NO contacts 2
Number of door position positively driven contacts 2
Number of guard lock monitoring positively driven contacts 2
Extraction force 30 N
Actuation frequency max. 1200 1/h
Actuating force 35 N
Lid black
Installation orientation any
Insertion depth 52 mm
Mechanical life 1 x 10⁶
Retention force 10 N
Switching principle Slow-action switching contact
Degree of protection IP65
Ambient temperature -25 ... +80 °C
Material
Housing Anodized die-cast alloy
Contact Silver alloy, gold flashed
Locking force Fmax 2000 N
Locking force FZh 1500 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Monitoring of the guard position3x10620 y
Important! Values valid at DC-13 100 mA/24V
Monitoring of guard locking3x10620 y
Important! Values valid at DC-13 100 mA/24V


PLMaximum SILCategoryMission time
Control of guard lockingDepending on external control of guard locking20 y


Miscellaneous

C number
C2123 with auxiliary release, escape release and protective plate

In combination with actuator ACTUATOR-Z-G

Overtravel 4 mm

In combination with actuator ACTUATOR-Z-GN

Overtravel 16 mm

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 12,5 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 097347
Item designation TZ1LE024RC18VAB-C2123
Gross weight 1,444kg
Customs tariff number 85365019000
ECLASS 27-27-26-03 Safety switch with guard control

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.