Handwheel HKD
- 100 detents per revolution
- Wear-free magnetic detent mechanism
- 100 pulses per revolution
- Installation in operator panels and EUCHNER hand-held pendant stations series HBL
Description
Notes
- Output G05 suitable for Fanuc control systems
Functional drawings
Dimensional drawings
Connection examples
Technical data
Approvals
Electrical connection values
Output type | Push-pull |
Output voltage | |
HIGH(1) | min. 4.0 V DC at 0 mA |
HIGH(1) | min. 3.0 V DC at 20 mA |
LOW(0) | max. 1.3 V DC at 15 mA |
HIGH(1) | min. 3.4 V DC at 5 mA |
Operating voltage DC | 5 V DC -5% ... +5% |
EMC protection requirements | |
according to CE | EN 61000-6-2, EN 61000-6-4 |
Pulses per revolution | 2x100 |
Current consumption | |
without load | max. 80 mA |
Mechanical values and environment
Connection type | Ribbon cable with socket connector, DIN 41651, 6-pin (Length approx. 250 mm) |
Atmospheric humidity | |
(condensation not permissible) | 80 % rH |
Detent positions per revolution | 100 |
Shock and vibration resistance | according to EN 60068-2-27/-2-6 |
Degree of protection | |
according to NEMA | 250-12 (on the front) |
IP65 (on the front) | |
Ambient temperature | 0 ... +70 °C |
Material | Aluminum |
Miscellaneous
Detent mechanism | Magnetic |
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
Other Documents
CAD data
Ordering data
Ordernumber | 091527 |
Item designation | HKD100V100G05 |
Gross weight | 0,341kg |
Customs tariff number | 85365019000 |
ECLASS | 27-24-23-07 Command-, control-, signal appliance |