Locking set MGB-L1H-APA... (guard locking by spring force) with 3 pushbuttons, M12 for enabling switch, RC18
- Guard locking with guard lock monitoring
- 3 pushbuttons (illuminated, wh, ye, bu and printed)
- With plug connector RC18
- With plug connector M12 for enabling switch
- Unicode
Description
Guard locking type
MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
Door hinge
A mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier.
LED indicator
The LED indicator indicates all important system and status information.
Monitoring outputs
OT | Bolt tongue inserted into the evaluation module |
OI | Diagnostics; there is a fault |
Pushbuttons
S2 | 1 NO contact, white, illuminated and printed |
S3 | 1 NO contact, yellow, illuminated and printed |
S4 | 1 NO contact, blue, illuminated and printed |
Connection for enabling switch
The device has an M12 plug connector for the direct connection of an enabling switch (e.g. ZSA, order no.: 110560).
Dimensional drawings
Dimensional drawings
Dimensional drawings
Connection examples
Technical data
Approvals
Handle modules MGB-H-AA1A3-R-111157 (Order no. 111157)
Mechanical values and environment
Installation orientation | Door hinge DIN right |
Degree of protection | IP65 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Miscellaneous
Product version number | V3.0.0 |
Additional feature | with automatic lockout mechanism |
Locking modules MGB-L1-APA-AA6A1-S5-R-114235 (Order no. 114235)
Operating and display elements
Occupancy diagram | L1 |
Item | Color | Extras | Switching element | Version | Note slide-in label | Slide-in label | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
2 | white | printed | 1NO | Illuminated pushbutton | |||||
3 | Yellow | printed | 1NO | Illuminated pushbutton | |||||
4 | Blue | printed | 1NO | Illuminated pushbutton |
Electrical connection values
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Discrepancy time | |
between FO1A and FO1B | max. 10 ms |
Utilization category | |
DC-13 | 24 V 200 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Risk time according to EN 60947-5-3 | max. 350 ms |
Safety class | III |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Solenoid control input IMP1, IMP2, IMM | |
Test pulse duration | max. 5 ms |
Test pulse interval | min. 100 ms |
Controls and indicators | |
Breaking capacity | max. 0.25 W |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
LED power supply | 24 V DC |
Monitoring outputs OD, OT, OL, OI | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC (Value at a switching current of 50mA without taking into account the cable lengths) |
Output current | max. 50 mA |
Safety outputs FO1A, FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths) |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
per safety output FO1A / FO1B | 1 ... 200 mA |
Test pulse duration | max. 0.3 ms |
Test pulse interval | min. 100 ms |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Current consumption | |
IUA | max. 375 mA ((with energized guard locking solenoid and unloaded outputs OD, OT, OL, OI, +20 °C, 24V)) |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Current consumption | |
IUB | max. 80 mA ((no load on outputs)) |
Mechanical values and environment
Connection type | |
Plug connector RC18 (X6) | |
Plug connector SFF5 (X7) | |
Installation orientation | Door hinge DIN right |
Switching frequency | 0.25 Hz |
Mechanical life | |
1 x 10⁶ | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
Degree of protection | IP65 |
Ambient temperature | |
at UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Control of guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Monitoring of guard locking and the guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Miscellaneous
Product version number | V4.0.0 |
Components
MGB-H-AA1A3-R-111157
Handle module MGB-H-...
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle
MGB-L1-APA-AA6A1-S5-R-114235
Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, M12 for enabling switch, RC18
- Guard locking with guard lock monitoring
- 3 pushbuttons (illuminated, wh, ye, bu and printed)
- With plug connector RC18
- With plug connector M12 for enabling switch
- Unicode
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Other Documents
CAD data
Ordering data
Ordernumber | 114236 |
Item designation | MGB-L1H-APA-R-114236 |
Gross weight | 2,317kg |
Customs tariff number | 85371098 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |