EUCHNER – More than safety.
EUCHNER – More than safety.

MGB-L2-APA-AG8A1-S1-L-115670 (Order no. 115670)

Locking module MGB-L2-APA.., (guard locking by solenoid force) with 3 pushbuttons, emergency stop, RC18

  • Guard locking with guard lock monitoring
  • Emergency stop according to ISO 13850
  • 3 pushbuttons, illuminated and printed (gn, wh, wh)
  • With plug connector RC18
  • Unicode
  • Common monitoring output for diagnostics and emergency stop
MGB-L2-APA-AG8A1-S1-L-115670 (Order no. 115670)

Description

Guard locking type

MGB-L2...

The locking arm is held in the locked position by solenoid force and is unlocked by spring force when the solenoid is switched off (open-circuit current principle, electrically locked).

Door hinge

A mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Monitoring outputs

OT

Bolt tongue inserted into the evaluation module

OI

Diagnostics; there is a fault

Emergency stop device

S1

2 positively driven contacts and 1 NO contact (e.g. monitoring contact), emergency stop with turn-to-reset, not illuminated

Pushbuttons

S2

1 NO contact, illuminated and printed

S3

1 NO contact, illuminated and printed

S4

1 NO contact, illuminated and printed

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Technical data

Approvals

c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-09_

Operating and display elements

Occupancy diagram L1
ItemColorExtrasNote slide-in labelSwitching elementSlide-in labelVersionNumberDesignation1LED
1with monitoring contact2 PD + 1 NOEmergency stop
2Greenprinted1NOIlluminated pushbutton
3whiteprinted1NOIlluminated pushbutton
4whiteprinted1NOIlluminated pushbutton

Electrical connection values

Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1.5 kV
Discrepancy time
between FO1A and FO1B max. 10 ms
Utilization category
DC-13 24 V 200 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Risk time according to EN 60947-5-3 max. 350 ms
Safety class III
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
Solenoid control input IMP1, IMP2, IMM
Test pulse duration max. 5 ms
Test pulse interval min. 100 ms
Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage UA V
Switching current 1 ... 10 mA
LED power supply 24 V DC
Emergency stop
Breaking capacity max. 0.25 W
Switching voltage 5 ... 24 V
Switching current 1 ... 100 mA
LED power supply 24 V DC
Monitoring outputs OD, OT, OL, OI
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC (Value at a switching current of 50mA without taking into account the cable lengths)
Output current max. 50 mA
Safety outputs FO1A, FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
UFO1A /UFO1B HIGH UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
UFO1A /UFO1B LOW 0 ... 1 V DC
Output current
per safety output FO1A / FO1B 1 ... 200 mA
Test pulse duration max. 0.3 ms
Test pulse interval min. 100 ms
Power supply UA
Operating voltage DC
UA 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Current consumption
IUA max. 375 mA ((with energized guard locking solenoid and unloaded outputs OD, OT, OL, OI, +20 °C, 24V))
Power supply UB
Operating voltage DC
UB 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Current consumption
IUB max. 80 mA ((no load on outputs))

Mechanical values and environment

Connection type Plug connector RC18 (X6)
Installation orientation Door hinge DIN left
Switching frequency 0.25 Hz
Mechanical life
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
1 x 10⁶
Degree of protection IP65
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel
Locking force FZh 2000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e-3.7x10-9420 y
Monitoring of guard lockingPL e-3.7x10-9420 y


B10DMission time
Emergency stop0.13x10620 y


Miscellaneous

Product version number V4.0.0

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 43,6 MB)

Single Documents

Doc. no.
Version
Language
Size
Doc. no. 2119167
Operating Instructions Safety Systems MGB-L1…-AR.-… / MGB-L2…-AR.-… and MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,9 MB
Doc. no. 2119167
Mode d’emploi Systèmes de sécurité MGB-L1…-AR.-… / MGB-L2…-AR.-… et MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,9 MB
Doc. no. 2119167
Manual de instrucciones Sistemas de seguridad MGB-L1…-AR.-…/MGB-L2…-AR.-… y MGB-L1…-AP.-…/MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,9 MB
Doc. no. 2119167
Betriebsanleitung Sicherheitssysteme MGB-L1…-AR.-… / MGB-L2…-AR.-… und MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,9 MB
Doc. no. 2119167
Manual de instruções Sistemas de segurança MGB-L1…-AR.-… / MGB-L2…-AR.-… e MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,8 MB
Doc. no. 2119167
Istruzioni di impiego Sistemi di sicurezza MGB-L1…-AR.-… / MGB-L2…-AR.-… e MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,9 MB
Doc. no. 2119167
使用说明书 安全系统 MGB-L1…-AR.-… / MGB-L2…-AR.-…和MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,2 MB
Doc. no. 2119167
操作説明書 安全システム MGB-L1…-AR.-… / MGB-L2…-AR.-… および MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,2 MB
Doc. no. 2119167
사용 설명서 안전 시스템 MGB-L1…-AR.-… / MGB-L2…-AR.-… 및 MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,2 MB
Doc. no. 2119167
Инструкция по эксплуатации Предохранительные системы MGB-L1…-AR.-… / MGB-L2…-AR.-… и MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,3 MB
Doc. no. 2119167
Návod k použití Bezpečnostní systémy MGB-L1…-AR.-… / MGB-L2…-AR.-… a MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,3 MB
Doc. no. 2119167
Gebruiksaanwijzing Beveiligingssystemen MGB-L1…-AR.-… / MGB-L2…-AR.-… en MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,8 MB
Doc. no. 2119167
Instrukcja obsługi Systemy bezpieczeństwa MGB-L1…-AR.-… / MGB-L2…-AR.-… i MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,3 MB
Doc. no. 2119167
Instruktionsbok Säkerhetssystem MGB-L1…-AR.-…/MGB-L2…-AR.-… och MGB-L1…-AP.-…/MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,9 MB
Doc. no. 2119167
Návod na prevádzku Bezpečnostné systémy MGB-L1…-AR.-… / MGB-L2…-AR.-… a MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,3 MB
Doc. no. 2119167
İşletim kılavuzu Emniyet sistemleri MGB-L1…-AR.-… / MGB-L2…-AR.-… ve MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,2 MB
Doc. no. 2119167
Інструкція з експлуатації запобіжних систем MGB-L1…-AR.-… / MGB-L2…-AR.-… і MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,3 MB

Other Documents

Ordering data

Ordernumber 115670
Item designation MGB-L2-APA-AG8A1-S1-L-115670
Gross weight 1,112kg
Customs tariff number 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.