Locking set MGB-L2H-APA... (guard locking by solenoid force) with 3 pushbuttons, emergency stop, RC18
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850
- 2 pushbuttons, illuminated (gn, wh)
- 1 pushbutton, not illuminated (wh)
- With plug connector RC18
- Unicode
Description
Guard locking type
MGB-L2... | The locking arm is held in the locked position by solenoid force and is unlocked by spring force when the solenoid is switched off (open-circuit current principle, electrically locked). |
Door hinge
A mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier.
LED indicator
The LED indicator indicates all important system and status information.
Monitoring outputs
OT | Bolt tongue inserted into the evaluation module |
OI | Diagnostics; there is a fault |
Emergency stop device
S1 | 2 positively driven contacts, emergency stop with turn-to-reset, not illuminated |
Pushbuttons
S2 | 1 NO contact, illuminated |
S3 | 1 NO contact, illuminated |
S4 | 1 NO contact, not illuminated |
Dimensional drawings
Dimensional drawings
Connection examples
Technical data
Approvals
Handle modules MGB-H-AA1A1-R-100464 (Order no. 100464)
Mechanical values and environment
Installation orientation | Door hinge DIN right |
Degree of protection | IP65 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Miscellaneous
Product version number | V3.0.0 |
Locking modules MGB-L2-APA-AC6A1-S1-R-110500 (Order no. 110500)
Operating and display elements
Occupancy diagram | L1 |
Item | Color | Extras | Slide-in label | Version | Switching element | Note slide-in label | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
1 | with monitoring contact | Emergency stop | 2 PD + 1 NO | ||||||
2 | Green | printed | Illuminated pushbutton | 1NO | |||||
3 | white | printed | Illuminated pushbutton | 1NO | |||||
4 | white | printed | Pushbutton | 1NO |
Electrical connection values
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Discrepancy time | |
between FO1A and FO1B | max. 10 ms |
Utilization category | |
DC-13 | 24 V 200 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Risk time according to EN 60947-5-3 | max. 350 ms |
Safety class | III |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Solenoid control input IMP1, IMP2, IMM | |
Test pulse duration | max. 5 ms |
Test pulse interval | min. 100 ms |
Controls and indicators | |
Breaking capacity | max. 0.25 W |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
LED power supply | 24 V DC |
Emergency stop | |
Breaking capacity | max. 0.25 W |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
LED power supply | 24 V DC |
Monitoring outputs OD, OT, OL, OI | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC (Value at a switching current of 50mA without taking into account the cable lengths) |
Output current | max. 50 mA |
Safety outputs FO1A, FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths) |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
per safety output FO1A / FO1B | 1 ... 200 mA |
Test pulse duration | max. 0.3 ms |
Test pulse interval | min. 100 ms |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Current consumption | |
IUA | max. 375 mA ((with energized guard locking solenoid and unloaded outputs OD, OT, OL, OI, +20 °C, 24V)) |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Current consumption | |
IUB | max. 80 mA ((no load on outputs)) |
Mechanical values and environment
Connection type | Plug connector RC18 (X6) |
Installation orientation | Door hinge DIN right |
Switching frequency | 0.25 Hz |
Mechanical life | |
1 x 10⁶ | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
Degree of protection | IP65 |
Ambient temperature | |
at UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Emergency stop | |
B10D | |
Emergency stop | 0.13 x 10⁶ |
Monitoring of guard locking and the guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Miscellaneous
Product version number | V4.0.0 |
Components
100464
MGB-H-AA1A1-R-100464
Handle module MGB-H-...
MGB-H-AA1A1-R-100464
Handle module MGB-H-...
- Intelligent bolt tongue
- Lockout mechanism
- Door handle
110500
MGB-L2-APA-AC6A1-S1-R-110500
Locking module MGB-L2-APA.., (guard locking by solenoid force) with 3 pushbuttons, emergency stop, RC18
MGB-L2-APA-AC6A1-S1-R-110500
Locking module MGB-L2-APA.., (guard locking by solenoid force) with 3 pushbuttons, emergency stop, RC18
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850
- 2 pushbuttons, illuminated (gn, wh)
- 1 pushbutton, not illuminated (wh)
- With plug connector RC18
- Unicode
Accessories
Connection material
Function expansion
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2123150
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001505
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Safety Systems MGB-L1…-AR.-… / MGB-L2…-AR.-… and MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
Version
Language
Size
Operating Instructions Safety Systems MGB-L1…-AR.-… / MGB-L2…-AR.-… and MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,9 MB
Mode d’emploi Systèmes de sécurité MGB-L1…-AR.-… / MGB-L2…-AR.-… et MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,9 MB
Manual de instrucciones Sistemas de seguridad MGB-L1…-AR.-…/MGB-L2…-AR.-… y MGB-L1…-AP.-…/MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,9 MB
Betriebsanleitung Sicherheitssysteme MGB-L1…-AR.-… / MGB-L2…-AR.-… und MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,9 MB
Manual de instruções Sistemas de segurança MGB-L1…-AR.-… / MGB-L2…-AR.-… e MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,8 MB
Istruzioni di impiego Sistemi di sicurezza MGB-L1…-AR.-… / MGB-L2…-AR.-… e MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,9 MB
使用说明书 安全系统 MGB-L1…-AR.-… / MGB-L2…-AR.-…和MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,2 MB
操作説明書 安全システム MGB-L1…-AR.-… / MGB-L2…-AR.-… および MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,2 MB
사용 설명서 안전 시스템 MGB-L1…-AR.-… / MGB-L2…-AR.-… 및 MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,2 MB
Инструкция по эксплуатации Предохранительные системы MGB-L1…-AR.-… / MGB-L2…-AR.-… и MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,3 MB
Návod k použití Bezpečnostní systémy MGB-L1…-AR.-… / MGB-L2…-AR.-… a MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,3 MB
Gebruiksaanwijzing Beveiligingssystemen MGB-L1…-AR.-… / MGB-L2…-AR.-… en MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,8 MB
Instrukcja obsługi Systemy bezpieczeństwa MGB-L1…-AR.-… / MGB-L2…-AR.-… i MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,3 MB
Instruktionsbok Säkerhetssystem MGB-L1…-AR.-…/MGB-L2…-AR.-… och MGB-L1…-AP.-…/MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
3,9 MB
Návod na prevádzku Bezpečnostné systémy MGB-L1…-AR.-… / MGB-L2…-AR.-… a MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,3 MB
İşletim kılavuzu Emniyet sistemleri MGB-L1…-AR.-… / MGB-L2…-AR.-… ve MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,2 MB
Інструкція з експлуатації запобіжних систем MGB-L1…-AR.-… / MGB-L2…-AR.-… і MGB-L1…-AP.-… / MGB-L2…-AP.-…
Doc. no.
2119167
Version
09/23
Language
Size
4,3 MB
Other Documents
Approvals and certificates
FCC
Doc. no.
Version
Language
Size
FCC
Doc. no.
Version
Language
Size
0,2 MB
IC
Doc. no.
Version
Language
Size
IC
Doc. no.
Version
Language
Size
0,6 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
0,7 MB
CAD data
Ordering data
Ordernumber | 110460 |
Item designation | MGB-L2H-APA-R-110460 |
Gross weight | 2,308kg |
Customs tariff number | 85371098 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |