Bus module MGB-B...-PN... with 3 controls and indicators, push-pull plug
- 1 cover for indicators
- 1 operating mode selector
- 1 illuminated pushbuttons
- including adhesive labels
- Push-pull plug
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
Description
Profinet connection
Connection via push-pull plugs according to IEC 61076-3-117
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.
Dimensional drawings
Technical data
Approvals
Operating and display elements
Occupancy diagram | B2 |
Item | Color | Extras | Switching element | Slide-in label | Note slide-in label | Version | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
11 | Red | Cover for indicators | |||||||
12 | white | 1NO | Illuminated pushbutton | ||||||
13 | Code 2 of 3 | Entsichert / Unsecured ; Sonderfunktion / Special function ; Gesichert Zentral / Secured Central | Operating mode selector |
Electrical connection values
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
maximum feed-in current in the connection block | |
X1, X2 | max. 4000 mA |
Safety class | III |
Current consumption | max. 500 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Power supply X1 | |
Fuse | |
external | min. 1 A slow blow |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Mechanical values and environment
Connection type | |
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 (X4 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) |
Push-pull power (X2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) | |
Push-pull power (X1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) | |
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 (X3 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) |
Installation orientation | any |
Switching frequency | 0.25 Hz |
Response time | |
Operating mode selector | max. 220 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP54 |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Diagnostic Coverage (DC) | 99 % |
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Safe multi-position switch | PL e | 3 | 4.1x10-8 | 4 | 20 y |
Miscellaneous
Slide-in label | ||||||||||||||||
| ||||||||||||||||
Product version number | V3.23.3 |
Interface
Bus data protocol | Profinet (IEC 61158 type 10) |
Safety data protocol | Profisafe (IEC 61784-3-3) |
Date interface | |
Ethernet |
Accessories
ZSA
ZSA, 3-stage, with cable and plug connector RC12
092141
ZSA092141C2038
ZSA092141C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 5 m
- Direct connection to safety switch
097567
ZSA097567C2038
ZSA097567C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 10 m
- Direct connection to safety switch
099495
ZSA099495C2038
ZSA099495C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 15 m
- Direct connection to safety switch
100873
ZSA100873C2038
ZSA100873C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 25 m
- Direct connection to safety switch
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2123624
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001506
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type A
Doc. no.
Version
Language
Size
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type A
Doc. no.
2114575
Version
03/24
Language
Size
3,4 MB
Betriebsanleitung Sicherheitssysteme MGB-L..B-PN.-… (PROFINET) und mit Datenstruktur Typ A
Doc. no.
2114575
Version
03/24
Language
Size
3,4 MB
Other Documents
Approvals and certificates
ProfiNET
Doc. no.
Version
Language
Size
ProfiNET
Doc. no.
Version
Language
Size
0,1 MB
TUEV Süd München
Doc. no.
Version
Language
Size
TUEV Süd München
Doc. no.
Version
Language
Size
4,0 MB
TUEV Süd München M6A Zertifikat
Doc. no.
Version
Language
Size
TUEV Süd München M6A Zertifikat
Doc. no.
Version
Language
Size
0,3 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
0,7 MB
CAD data
Ordering data
Ordernumber | 105287 |
Item designation | MGB-B-A1W2A2-PN-105287 |
Gross weight | 2,28kg |
Customs tariff number | 85371098 |
ECLASS | 27-24-26-07 Field bus, decentralized peripheral - basic device |