EUCHNER – More than safety.
EUCHNER – More than safety.

MGB-CB-PN-124822 (Order no. 124822)

Control panel MGB-...-PN with 11 controls and indicators, 7/8" and M12 plugs, RC12

  • Control panel
  • Emergency stop according to ISO 13850, illuminated
  • 9 illuminated pushbuttons
  • Operating mode selector
  • Connection via 7/8" and M12 plugs
  • including terminal plug for stack light (M12, 5-pin)
  • including terminal plug for enabling switch (RC12, 12-pin)
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
MGB-CB-PN-124822 (Order no. 124822)

Description

Profinet connection

7/8" plugs according to ANSI/B93.55M-1981 and M12 plugs (d-coded) according to IEC 61076-2-101

Profinet RT switch

Point-to-point topology network structure due to integrated RT switch.

Illuminated emergency stop

Emergency stop with illumination that can be controlled as required.

Dimension drawing
Dimension drawing

Dimensional drawings

Dimensional drawings

Technical data

Approvals

EAC_RU C-DE.HX37.B.14157/20

Operating and display elements

Occupancy diagram
C1
B2
ItemColorExtrasSwitching elementSlide-in labelNote slide-in labelVersionNumberDesignation1LED
10white1NOIlluminated pushbutton
11white1NOIlluminated pushbutton
12Greenprinted1NOIlluminated pushbutton
132 PDEmergency stop illuminated
14whiteprinted1NOIlluminated pushbutton
15Yellowprinted1NOIlluminated pushbutton
16white1NOIlluminated pushbutton
17white1NOIlluminated pushbutton
90whiteprinted1NOIlluminated pushbutton
91Code 2 of 3O ; IOperating mode selector
92Blueprinted1NOIlluminated pushbutton

Electrical connection values

Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
maximum feed-in current in the connection block
X1, X2 max. 4000 mA
Safety class III
Current consumption max. 500 mA
Degree of contamination (external, according to EN 60947-1) 3
Power supply X1
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... +10% (For looping through for connected devices)
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (For looping through for connected devices)

Mechanical values and environment

Connection type
7/8" Power (X1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
7/8" Power (X2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
for enabling switch Plug connector RC12 (X14)
for Stacklight Plug connector M12 (X6)
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12, D-coded, screened (X3 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12, D-coded, screened (X4 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
Installation orientation any
Switching frequency 0.25 Hz
Response time
Operating mode selector max. 220 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Enabling switch max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP54
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Diagnostic Coverage (DC) 99 %
PLMaximum SILPFHDCategoryMission time
Safe multi-position switchPL e34.1x10-8420 y
Evaluating safety signalsPL e34.1x10-8420 y
Applies to all additionally included safety functions such as EMERGENCY STOP, enabling switch, etc.


B10DMission time
Emergency stop0.13x10620 y


Miscellaneous

Product version number V3.30.10

Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)
Date interface
Ethernet

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 6,5 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 124822
Item designation MGB-CB-PN-124822
Gross weight 3,407kg
Customs tariff number 85371098

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.